scleral graft
Recently Published Documents


TOTAL DOCUMENTS

34
(FIVE YEARS 11)

H-INDEX

8
(FIVE YEARS 1)

Author(s):  
Nisa Silva ◽  
Jan Geert Bollemeijer ◽  
André Ferreira ◽  
Maria João Menéres ◽  
Hans Lemij

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Panagiotis Laspas ◽  
Jochen Wahl ◽  
Henning Peters ◽  
Verena Prokosch-Willing ◽  
Panagiotis Chronopoulos ◽  
...  
Keyword(s):  

2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Panagiotis Laspas ◽  
Jochen Wahl ◽  
Henning Peters ◽  
Verena Prokosch-Willing ◽  
Panagiotis Chronopoulos ◽  
...  
Keyword(s):  

2020 ◽  
Vol 104 (S3) ◽  
pp. S192-S192
Author(s):  
Kyungmee Park ◽  
Seo-Young Choi ◽  
Hyun Kwon ◽  
Ka-Young Lim
Keyword(s):  

2020 ◽  
Vol 2020 ◽  
pp. 1-9 ◽  
Author(s):  
Faried M. Wagdy

Objective. To compare between the surgical outcomes of Tenon capsule grafting and autologous scleral graft in Ahmed glaucoma valve (AGV) surgery in the management of refractory glaucoma and prevention of tube exposure. Patients and Methods. This prospective randomised study included 30 eyes of 30 patients with refractory glaucoma, who were aged between 46 and 58 years and diagnosed with refractory glaucoma. This study was conducted in Menofia University Hospital between July 2018 and December 2019. Informed patient consent was obtained. The studied eyes were divided into two groups: the first group included 15 eyes for which AGV with Tenon capsule grafting was performed, while the second group included 15 eyes for which AGV with autologous scleral graft was performed. All patients were followed up for one year after the surgery. The outcomes were evaluated according to intraocular pressure (IOP) and the number of postoperative glaucoma medications. Visual acuity, visual field, number of postoperative glaucoma medications, and postoperative complications were followed throughout the 1-year follow-up period. Results. There was a significant reduction in IOP in both groups, with more reduction in the Tenon graft group where the mean IOP after one year was 11.66 ± 0.89 mmHg, whereas in the scleral graft group, the mean IOP was 14.20 ± 4.0 mmHg (p value < 0.001). However, the difference between the 2 groups in lowering IOP was insignificant. Regarding postoperative complications, tube exposure was observed in one case in the scleral graft group with associated scleral melting and hypotony, postoperative hypotony was more in the scleral graft group with 3 cases (20%), and in the Tenon graft group, hypotony occurred only in 1 case (6.67%). In addition, less vascular blebs were seen in most cases in the Tenon graft group, while most blebs seen in the scleral graft group were vascular blebs. In addition, both groups showed stability in terms of visual acuity and visual field. Conclusion. Tenon capsule grafting and autologous scleral grafting might be effective and safe techniques when applied with AGV in the management of refractory glaucoma. Tenon capsule resection with grafting showed relatively low incidence of tube exposure and hypertensive phase.


2020 ◽  
pp. 112067212092531
Author(s):  
Chih-Hung Kuo

Purpose To describe a surgical technique to optimize XEN gel stent position and its outflow. Methods A small 1- to 1.5-mm square lamellar sclerectomy was created at the external tip of the XEN gel stent implant. The lamellar scleral tissue, served as a patch graft, was secured at the gel stent insertion site. Results Four sequential, unselected, patients with failed primary XEN gel stent surgeries underwent bleb revisions with the technique described. These four patients achieved unmedicated intraocular pressures between 10 and 12 mmHg and a favourable bleb morphology despite repeated mitomycin C applications at 6 months. Conclusion Lamellar sclerectomy with auto-scleral graft augmented XEN gel stent surgery deliver successful short-term outcomes without major complications observed.


Sign in / Sign up

Export Citation Format

Share Document