An integrated neural network for the dynamic domestic energy management of a solar house

Author(s):  
Nadia Drir ◽  
Fathia Chekired ◽  
Djamila Rekioua
Energy ◽  
2021 ◽  
pp. 122727
Author(s):  
Zhihang Chen ◽  
Yonggang Liu ◽  
Yuanjian Zhang ◽  
Zhenzhen Lei ◽  
Zheng Chen ◽  
...  

2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Oluwafemi Ajayi ◽  
Reolyn Heymann

Purpose Energy management is critical to data centres (DCs) majorly because they are high energy-consuming facilities and demand for their services continue to rise due to rapidly increasing global demand for cloud services and other technological services. This projected sectoral growth is expected to translate into increased energy demand from the sector, which is already considered a major energy consumer unless innovative steps are used to drive effective energy management systems. The purpose of this study is to provide insights into the expected energy demand of the DC and the impact each measured parameter has on the building's energy demand profile. This serves as a basis for the design of an effective energy management system. Design/methodology/approach This study proposes novel tunicate swarm algorithm (TSA) for training an artificial neural network model used for predicting the energy demand of a DC. The objective is to find the optimal weights and biases of the model while avoiding commonly faced challenges when using the backpropagation algorithm. The model implementation is based on historical energy consumption data of an anonymous DC operator in Cape Town, South Africa. The data set provided consists of variables such as ambient temperature, ambient relative humidity, chiller output temperature and computer room air conditioning air supply temperature, which serve as inputs to the neural network that is designed to predict the DC’s hourly energy consumption for July 2020. Upon preprocessing of the data set, total sample number for each represented variable was 464. The 80:20 splitting ratio was used to divide the data set into training and testing set respectively, making 452 samples for the training set and 112 samples for the testing set. A weights-based approach has also been used to analyze the relative impact of the model’s input parameters on the DC’s energy demand pattern. Findings The performance of the proposed model has been compared with those of neural network models trained using state of the art algorithms such as moth flame optimization, whale optimization algorithm and ant lion optimizer. From analysis, it was found that the proposed TSA outperformed the other methods in training the model based on their mean squared error, root mean squared error, mean absolute error, mean absolute percentage error and prediction accuracy. Analyzing the relative percentage contribution of the model's input parameters based on the weights of the neural network also shows that the ambient temperature of the DC has the highest impact on the building’s energy demand pattern. Research limitations/implications The proposed novel model can be applied to solving other complex engineering problems such as regression and classification. The methodology for optimizing the multi-layered perceptron neural network can also be further applied to other forms of neural networks for improved performance. Practical implications Based on the forecasted energy demand of the DC and an understanding of how the input parameters impact the building's energy demand pattern, neural networks can be deployed to optimize the cooling systems of the DC for reduced energy cost. Originality/value The use of TSA for optimizing the weights and biases of a neural network is a novel study. The application context of this study which is DCs is quite untapped in the literature, leaving many gaps for further research. The proposed prediction model can be further applied to other regression tasks and classification tasks. Another contribution of this study is the analysis of the neural network's input parameters, which provides insight into the level to which each parameter influences the DC’s energy demand profile.


2019 ◽  
Vol 111 ◽  
pp. 05020 ◽  
Author(s):  
Ziwei Xiao ◽  
Jiaqi Yuan ◽  
Wenjie Gang ◽  
Chong Zhang ◽  
Xinhua Xu

The demand of building energy management has increased due to high energy saving potentials. Load monitor and disaggregation can provide useful information for building energy management systems with detailed and individual loads of the building, so corresponding energy efficient measures can be taken to reduce the energy consumption of buildings. The technique is investigated widely in residential buildings known as Non-Intrusive Load Monitoring (NILM). However, relevant studies are not sufficient for non-residential buildings, especially for the cooling loads. This paper proposes a NILM method for cooling load disaggregation using artificial neural network. The cooling load is disaggregated into four categories: building envelope load, occupant load, equipment load and fresh air load. Two approaches are used to realize the load disaggregation: one is based on the Fourier transfer of the cooling loads, the other takes the cooling load, dry-bulb temperature and humidity of outdoor air, and time as inputs. By implementing the methods in a metro station, the performance of the proposed method can be obtained. Results show that both approaches can realize the load disaggregation accurately, with a RMSE less than 11.2. The second approach is recommended with a higher accuracy.


2018 ◽  
Vol 31 (10) ◽  
pp. e4838 ◽  
Author(s):  
Yeqin Wang ◽  
Zhen Wu ◽  
Aoyun Xia ◽  
Chang Guo ◽  
Yuyan Chen ◽  
...  

2015 ◽  
Vol 137 (3) ◽  
Author(s):  
Martin Schmelas ◽  
Thomas Feldmann ◽  
Jesus da Costa Fernandes ◽  
Elmar Bollin

Solar energy converted and fed to the utility grid by photovoltaic modules has increased significantly over the last few years. This trend is expected to continue. Photovoltaics (PV) energy forecasts are thus becoming more and more important. In this paper, the PV energy forecasts are used for a predictive energy management system (PEMS) in a positive energy building. The publication focuses on the development and comparison of different models for daily PV energy prediction taking into account complex shading, caused for example by trees. Three different forecast methods are compared. These are a physical model with local shading measurements, a multilayer perceptron neural network (MLP), and a combination of the physical model and the neural network. The results show that the combination of the physical model and the neural network provides the most accurate forecast values and can improve adaptability. From April to December, the mean percentage error (MPE) of the MLP with physical information is 11.6%. From December to March, the accuracy of the PV predictions decreases to an MPE of 78.8%. This is caused by poorer irradiation forecasts, but mainly by snow coverage of the PV modules.