Tripping Over the Finish Line

Someday Rich ◽  
2012 ◽  
pp. 171-189
Keyword(s):  
PsycCRITIQUES ◽  
2015 ◽  
Vol 6060 (1212) ◽  
Author(s):  
Michael Sachs
Keyword(s):  

Sports ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 86
Author(s):  
Christoffer Nyborg ◽  
Helene Støle Melsom ◽  
Martin Bonnevie-Svendsen ◽  
Jørgen Melau ◽  
Ingebjørg Seljeflot ◽  
...  

We assessed endothelial function by flow-mediated dilatation (FMD), levels of the NO-precursor L-arginine, and markers of endothelial inflammation before, at the finish line, and one week after the Norseman Xtreme triathlon. The race is an Ironman distance triathlon with a total elevation of 5200 m. Nine male participants were included. They completed the race in 14.5 (13.4–15.3) h. FMD was significantly reduced to 3.1 (2.1–5.0)% dilatation compared to 8.7 (8.2–9.3)% dilatation before the race (p < 0.05) and was normalized one week after the race. L-arginine showed significantly reduced levels at the finish line (p < 0.05) but was normalized one week after the race. Markers of endothelial inflammation E-Selectin, VCAM-1, and ICAM-1 all showed a pattern with increased values at the finish line compared to before the race (all p < 0.05), with normalization one week after the race. In conclusion, we found acutely reduced FMD with reduced L-arginine levels and increased E-Selectin, VCAM-1, and ICAM-1 immediately after the Norseman Xtreme triathlon. Our findings indicate a transient reduced endothelial function, measured by the FMD-response, after prolonged strenuous exercise that could be explained by reduced NO-precursor L-arginine levels and increased endothelial inflammation.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Keunbada Son ◽  
Young-Tak Son ◽  
Ji-Min Lee ◽  
Kyu-Bok Lee

AbstractThis study evaluated the marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation scanned at four finish line locations. The right maxillary first molar tooth preparation model was fabricated using a ceramic material and placed in four finish line locations (supragingival, equigingival, subgingival, and subgingival with a cord). Intraoral scanning was performed. Crowns were designed based on the scanned area. Interim crowns were fabricated using a stereolithography three-dimensional (3D) printer (N = 16 per location). Marginal and internal fit were evaluated with a silicone replica technique. Intaglio surface trueness was evaluated using a 3D inspection software. One-way analysis of variance and Tukey HSD test were performed for comparisons (α = 0.05). The marginal and internal fit showed significant differences according to locations (P < 0.05); the marginal fit showed the best results in the supragingival finish line (P < 0.05). Intaglio surface trueness was significantly different in the marginal region, with the highest value in the subgingival location (P < 0.05). Crowns fabricated on the subgingival finish line caused inaccurate marginal fit due to poor fabrication reproducibility of the marginal region. The use of an intraoral scanner should be decided on the clinical situation and needs.


Sign in / Sign up

Export Citation Format

Share Document