EFFECT OF FINISH LINE DESIGN AND THERMO-MECHANICAL AGING ON THE FRACTURE RESISTANCE OF TWO TYPES OF MONOLITHIC ZIRCONIA CROWNS

2017 ◽  
Vol 63 (4) ◽  
pp. 3947-3953
Author(s):  
Khaled Haggag ◽  
Mohammed Hosny ◽  
Muhammad Abbas ◽  
Hussein Ramadan
2020 ◽  
Vol 23 (3) ◽  
Author(s):  
Mohamed Eldamaty ◽  
Mohammed Abdel-Aziz ◽  
Ahmed El-Kouedi ◽  
Tamer Hamza

Objective: The purpose of this study was to evaluate the effect of finish line design and cement space thickness on the marginal accuracy of monolithic zirconia crowns. Materials and methods: Thirty crowns were fabricated from translucent zirconia (inCoris TZI) using Cerec in-Lab system and divided into three main groups (10 each) according to the finish line type of the die (knife-edge, chamfer, and shoulder). Every group was divided into two subgroups (5 each) according to cement space thickness (20 and50μm). Optical impressions were taken for the dies using the Cerec scanner and cement space was set twice for every finish line design; 20 and 50 μm. The completed crowns were cemented to the dies and the marginal gap was evaluated. The collected data was statistically analyzed using Mann-Whitney U test and Kruskal-Wallis test and the significance level was set at P ≤ 0.05. Results: Regarding the marginal gap; there was no statistically significant difference between different finish line designs or between different cement space thicknesses. Conclusion: Neither finish line design nor cement space thickness has an effect on the marginal gap of inCoris TZI crowns.KeywordsCement space; Finish line; Marginal fit; Monolithic zirconia.


2021 ◽  
Vol 9 (10) ◽  
pp. 112
Author(s):  
Ramtin Sadid-Zadeh ◽  
Hadjer Sahraoui ◽  
Brian Lawson ◽  
Robert Cox

Purpose: The objective of this study was to assess the quality of posterior teeth prepared for monolithic zirconia crowns. Materials and Methods: A total of 392 STL-files of posterior preparations for monolithic zirconia crowns were evaluated in this study. Three-dimensional (3D) images were evaluated using a software (3D Viewer; 3Shape A/S, Copenhagen, Denmark) for finish line design, finish line width, occluso-cervical dimension, total occlusal convergence (TOC), intercuspal angulation, finish line quality, line angle form, and presence or absence of undercut at the axial wall and unsupported lip of enamel. The assessment was performed by two calibrated evaluators. Then, data were descriptively analyzed. Data for occluso-cervical dimension and TOC were descriptively analyzed according to their location. Results: Thirty-nine percent of premolars, 77% of first molars, and 91% of second molars had an average occluso-cervical dimension of less than 3 mm (premolars) and 4 mm (molars), with most of the preparations having a TOC of more than 20 degrees. More than 50% of preparations had undercut, unsupported enamel and/or unacceptable finish line quality. Conclusions: The quality of tooth preparation including finish line quality, absence of unsupported enamel and undercut at the axial wall should be evaluated when preparing monolithic zirconia crowns.


2020 ◽  
Vol 14 (02) ◽  
pp. 245-249
Author(s):  
Haider Hasan Jasim ◽  
Meelad Basil Findakly ◽  
Nada Ali Mahdi ◽  
Mustafa Tariq Mutar

Abstract Objectives The aim of this study was to compare the effects of two margin designs (shoulderless and slight chamfer) with two occlusal thicknesses on fracture resistance and failure mode of the monolithic zirconia crowns. Materials and Methods Forty nickel–chromium dies were duplicated from the previous two prepared teeth using a three-dimensional optical scanner. Nickel–chromium supporting dies were divided into two main groups (n = 20) according to the type of margin design: group A, slight chamfer margin design and group B, shoulderless margin design. These groups were further divided into two subgroups according to the occlusal thicknesses (0.5 and 1 mm). The digital imaging of each die was done using a three-dimensional optical scanner, then zirconia blocks were milled by 5-axis machine. The crowns were cleaned by alcohol, air dried, and cemented by resin cement. Next, the crowns were subjected to 500 hot and cold cycles (30 seconds for each cycle). The samples were subjected to a static load until failure using an electronic universal testing machine and fracture resistance was recorded in Newton (N). Statistical Analysis Data were analyzed using the test of normality (Shapiro–Wilk test) and two-way analysis of variance (ANOVA) test. Results  The highest mean fracture load was recorded by the shoulderless (1 mm occlusal thickness) subgroup (3,992.5 N), followed by shoulderless (0.5 mm occlusal thickness) subgroup (3,244.4 N), and the slight chamfer (1 mm occlusal thickness) subgroup (2,811 N). The lowest mean of fracture load was recorded by slight chamfer (0.5 mm occlusal thickness) subgroup (1,632.9 N). The two-way ANOVA test revealed a significant difference between the four subgroups. Regarding the fracture mode, the slight chamfer subgroups showed a severe fracture of the restoration while the shoulderless subgroups showed a fracture through the midline of the restoration. Conclusion Within the limitation of the comparative study, shoulderless margin design has a more favorable outcome than a slight chamfer design in all thicknesses. Although the restoration with reduced occlusal thickness has lower fracture resistance than 1 mm occlusal thickness, the 0.5 mm restorations still can tolerate occlusal forces.


Materials ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1623 ◽  
Author(s):  
Ting-Hsun Lan ◽  
Chin-Yun Pan ◽  
Pao-Hsin Liu ◽  
Mitch M. C. Chou

The aim of this study is to determine the minimum required thickness of a monolithic zirconia crown in the mandibular posterior area for patients with bruxism. Forty-nine full zirconia crowns, with seven different occlusal thicknesses of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm, were made by using a computer-aided design/computer-aided manufacturing system (CAD/CAM). Seven crowns in each group were subjected to cyclic loading at 800 N and 5 Hz in a servohydraulic testing machine until fracture or completion of 100,000 cycles. Seven finite element models comprising seven different occlusal thicknesses of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm were simulated using three different loads of vertical 800 N, oblique 10 degrees 800 N, and vertical 800 N + x N torque (x = 10, 50, and 100). The results of cyclic loading tests showed that the fracture resistance of the crown was positively associated with thickness. Specimen breakage differed significantly according to the different thicknesses of the prostheses (p < 0.01). Lowest von Mises stress values were determined for prostheses with a minimal thickness of 1.0 mm in different loading directions and with different forces. Zirconia specimens of 1.0 mm thickness had the lowest stress values and high fracture resistance and under 800 N of loading.


Sign in / Sign up

Export Citation Format

Share Document