Missing the Finish LineMissing the Finish Line

PsycCRITIQUES ◽  
2015 ◽  
Vol 6060 (1212) ◽  
Author(s):  
Michael Sachs
Keyword(s):  
Sports ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 86
Author(s):  
Christoffer Nyborg ◽  
Helene Støle Melsom ◽  
Martin Bonnevie-Svendsen ◽  
Jørgen Melau ◽  
Ingebjørg Seljeflot ◽  
...  

We assessed endothelial function by flow-mediated dilatation (FMD), levels of the NO-precursor L-arginine, and markers of endothelial inflammation before, at the finish line, and one week after the Norseman Xtreme triathlon. The race is an Ironman distance triathlon with a total elevation of 5200 m. Nine male participants were included. They completed the race in 14.5 (13.4–15.3) h. FMD was significantly reduced to 3.1 (2.1–5.0)% dilatation compared to 8.7 (8.2–9.3)% dilatation before the race (p < 0.05) and was normalized one week after the race. L-arginine showed significantly reduced levels at the finish line (p < 0.05) but was normalized one week after the race. Markers of endothelial inflammation E-Selectin, VCAM-1, and ICAM-1 all showed a pattern with increased values at the finish line compared to before the race (all p < 0.05), with normalization one week after the race. In conclusion, we found acutely reduced FMD with reduced L-arginine levels and increased E-Selectin, VCAM-1, and ICAM-1 immediately after the Norseman Xtreme triathlon. Our findings indicate a transient reduced endothelial function, measured by the FMD-response, after prolonged strenuous exercise that could be explained by reduced NO-precursor L-arginine levels and increased endothelial inflammation.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Keunbada Son ◽  
Young-Tak Son ◽  
Ji-Min Lee ◽  
Kyu-Bok Lee

AbstractThis study evaluated the marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation scanned at four finish line locations. The right maxillary first molar tooth preparation model was fabricated using a ceramic material and placed in four finish line locations (supragingival, equigingival, subgingival, and subgingival with a cord). Intraoral scanning was performed. Crowns were designed based on the scanned area. Interim crowns were fabricated using a stereolithography three-dimensional (3D) printer (N = 16 per location). Marginal and internal fit were evaluated with a silicone replica technique. Intaglio surface trueness was evaluated using a 3D inspection software. One-way analysis of variance and Tukey HSD test were performed for comparisons (α = 0.05). The marginal and internal fit showed significant differences according to locations (P < 0.05); the marginal fit showed the best results in the supragingival finish line (P < 0.05). Intaglio surface trueness was significantly different in the marginal region, with the highest value in the subgingival location (P < 0.05). Crowns fabricated on the subgingival finish line caused inaccurate marginal fit due to poor fabrication reproducibility of the marginal region. The use of an intraoral scanner should be decided on the clinical situation and needs.


Author(s):  
Jaber Hussain Akbar ◽  
Ridwaan Omar ◽  
Yacoub Al Tarakmah

Statement of problem- Research on evaluation of crowns made by the latest CAD/CAM systems for their marginal adaptation is scarce. Purpose- The purpose of this in vitro study was to evaluate the marginal integrity of crowns fabricated by the latest Chairside Economical Restorations of Esthetic Ceramic (CEREC) system using two different finish line preparation designs: Chamfer and Shoulder. Material and methods- Typhodont teeth were equally divided into two groups, group A and B. The teeth were prepared for full coverage crowns with a shoulder (group A) and chamfer finish line design (group B). An experienced prosthodontist prepared all crown preparations. Evaluation of six sites per sample was completed by two calibrated, experienced prosthodontists using the modified United States Public Health Services (USPHS) criteria. The descriptive statistics and Z-test were used to evaluate the results. Results- A total of 180 teeth were included in the study (90 teeth in each group). Only two crowns in group A and one crown in group B were clinically unacceptable. There was no statistical significance (p=0.282) between the two groups regarding finish-line design. Conclusions- CEREC system provides clinically acceptable crowns and can safely be utilized in dental treatment. Therefore, Contemporary Dental Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) restorations should be considered as a safe treatment modality by dental professionals.


Sign in / Sign up

Export Citation Format

Share Document