scholarly journals High‐sensitivity Cardiac Troponin T as a Predictor of Acute Total Occlusion in Patients with Non‐ST‐segment Elevation Acute Coronary Syndrome

Author(s):  
Rocío Baro ◽  
Sohaib Haseeb ◽  
Santiago Ordoñez ◽  
Juan Pablo Costabel
2010 ◽  
Vol 56 (4) ◽  
pp. 642-650 ◽  
Author(s):  
Evangelos Giannitsis ◽  
Meike Becker ◽  
Kerstin Kurz ◽  
Georg Hess ◽  
Dietmar Zdunek ◽  
...  

Abstract Background: We sought to determine the diagnostic performance of the new high-sensitivity cardiac troponin T (hs-cTnT) assay for early detection of non–ST-segment myocardial infarction (NSTEMI) in patients with acute coronary syndrome. Methods: We enrolled patients with retrospectively confirmed unstable angina or NSTEMI and an initially negative cTnT concentration and compared the performance of baseline concentrations and serial changes in concentration within 3 and 6 h. Percentage change criteria included ≥20% δ change and ROC-optimized value. Results: Based on the standard fourth-generation cTnT result of ≥0.03 μg/L, an evolving NSTEMI was diagnosed in 26 patients, and 31 patients were classified as having unstable angina. With the use of the hs-cTnT assay at the 99th-percentile cutoff, the percentage of NSTEMI cases detected increased gradually from 61.5% on presentation to 100% within 6 h, and the overall number of MI diagnoses increased by 34.6% (35 vs 26 cases). A δ change ≥20% or ≥ROC-optimized value of >117% within 3 h or ≥243% within 6 h yielded a specificity of 100% at sensitivities between 69% and 76%. The standard cTnT at the 99th percentile was less sensitive than hs-cTnT for early diagnosis of MI on presentation, and follow-up samples obtained within the initial 3 h demonstrated very low specificity of cTnT compared with hs-cTnT. Conclusions: The high-sensitivity cTnT assay increases the number of NSTEMI diagnoses and enables earlier detection of evolving NSTEMI. A doubling of the hs-cTnT concentration within 3 h in the presence of a second concentration ≥99th percentile is associated with a positive predictive value of 100% and a negative predictive value of 88%.


Author(s):  
Chen Dongxu ◽  
Zhou Yannan ◽  
Yang Yilin ◽  
Yao Chenling ◽  
Gu Guorong ◽  
...  

Abstract Objectives A rapid 0 h/1 h algorithm using high-sensitivity cardiac troponin T (hs-cTnT) for rule-out and rule-in of non-ST-segment elevation myocardial infarction (NSTEMI) is recommended by the European Society of Cardiology. We aim to prospectively evaluate the diagnostic performance of the algorithm in Chinese Han patients with suspected NSTEMI. Methods In this prospective diagnostic cohort study, 577 patients presenting to the emergency department with suspected NSTEMI and recent (<12 h) onset of symptoms were enrolled. The levels of serum hs-cTnT were measured on admission, 1 h later and 4–14 h later. All patients underwent the initial clinical assessment and were triaged into three groups (rule-out, rule-in and observe) according to the 0 h/1 h algorithm. The major cardiovascular events (MACE) were evaluated at the 7-day and 30-day follow-ups. Results Among 577 enrolled patients, NSTEMI was the final diagnosis for 106 (18.4%) patients. Based on the hs-cTnT 0 h/1 h algorithm, 148 patients (25.6%) were classified as rule-out, 278 patients (48.2%) as rule-in and 151 patients (26.2%) were assigned to the observe group. The rule-out approach resulted in a sensitivity of 100% and negative predictive value of 100%. The rule-in approach resulted in a specificity of 62.9% [95% CI (58.5–67.2%)] and positive predictive value of 37.1% [95%CI (31.3–42.8%)]. No MACE was observed in the rule-out group within 30-day follow-up. Conclusions The hs-cTnT 0 h/1 h algorithm is a safe tool for early rule-out of NSTEMI, while probably not an effective strategy for accurate rule-in of NSTEMI in Chinese Han population.


Sign in / Sign up

Export Citation Format

Share Document