Effect of horizontal ring beams on the ultimate bearing capacity of masonry walls

2013 ◽  
Vol 44 (5) ◽  
pp. 436-448 ◽  
Author(s):  
J. Radnic ◽  
M. Smilovic ◽  
A. Harapin ◽  
M. Sunara
2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Qiang Zhou ◽  
Lingyu Yang ◽  
Wenyang Zhao

Masonry structures are widely used in developing countries due to their low cost and simple construction, especially in remote areas, where there are a large number of houses without seismic measures. These buildings are prone to collapse and cause a lot of casualties, even under the action of small earthquakes. For the reinforcement of this structure, a cheap, effective, and easy-to-construct reinforcement method is urgently needed. Therefore, this article studies the reinforcement method of polypropylene bands (PP-bands). We have carried out low-frequency cyclic loading tests for two PP-band reinforced masonry walls and two compared masonry walls. We mainly studied the influence of PP-band and different compressive strengths of plastering mortar on the masonry wall’s seismic capacity. The seismic indicators mainly studied in this article include ultimate bearing capacity, energy dissipation capacity, stiffness degradation, and hysteresis characteristics. The experimental results show that the PP-band can greatly enhance the seismic capacity of the masonry wall. The ultimate bearing capacity, energy dissipation capacity, and displacement ductility of the PP-band reinforced wall are increased by 38%–48%, 22%–47%, and 138%–226%.


Author(s):  
Lianheng Zhao ◽  
Shan Huang ◽  
Zhonglin Zeng ◽  
Rui Zhang ◽  
Gaopeng Tang ◽  
...  

2014 ◽  
Vol 488-489 ◽  
pp. 497-500
Author(s):  
You Lin Zou ◽  
Pei Yan Huang

Deem test results from the low reversed cyclic loading quasi-static test with 2 RC columns as the basic information of secant stiffness damage of the reference column and take use of the TMS instrument in the test to artificially make the damage percentage of secant stiffness of the RC column as 33%, 50% and 66%, 6 damaged columns in total; reinforce the 6 damaged columns and 2 undamaged ones under the same conditions with AFL, through quasi-static contrast test. Test results show that it is able to effectively boost horizontal ultimate bearing capacity and ductility deformability of the RC columns with AFL for reinforcement; besides, there is a linear function relationship between horizontal ultimate bearing capacity, target ductility factor, and damage percentage of secant stiffness.


2011 ◽  
Vol 261-263 ◽  
pp. 989-993 ◽  
Author(s):  
Anuchit Uchaipichat ◽  
Ekachai Man Koksung

An experimental program of laboratory bearing tests was performed to characterize the bearing capacity of foundation on unsaturated granular soils. All tests were performed by pushing a circular rod on the surface of compacted sand specimens with different values of matric suction until failure. The test results show an increase in ultimate bearing capacity with increasing matric suction at low suction value but a decrease in that at high level of suction. The comparisons between the test results and simulations using the expressions proposed in this paper are presented and discussed. Good agreements are achieved for all testing values of suction.


Sign in / Sign up

Export Citation Format

Share Document