Development and Evaluation of a Tablet-Control for a Surgical Workstation in the Open Integrated Operating Room

Author(s):  
Johanna Hemmeke ◽  
Philipp Krumholz ◽  
Armin Janß ◽  
Klaus Radermacher
Author(s):  
Eva-Maria Zeißig ◽  
Armin Janß ◽  
Jasmin Dell’Anna-Pudlik ◽  
Martina Ziefle ◽  
Klaus Radermacher

AbstractAlarm conditions of the technical equipment in operating rooms represent a prevalent cause for interruptions of surgeons and scrub nurses, resulting in an increase of workload and potential reduction of patient safety. In this work, an alarm concept for an integrated operating room system based on open communication standards is developed and tested.In a laboratory experiment, the reactions of surgeons were analysed, comparing the displaying of alarms on an integrated workstation and on single devices: disruptive effects of alarm handling on primary task (ratings of perceived distraction, resumption lag, deterioration of speed, accuracy, and prospective memory), efficiency and effectiveness of identification of alarms, as well as perceived workload were included.The identification of the alarm cause is significantly more efficient and effective with the integrated alarm concept. Moreover, a slightly lower deterioration of performance of the primary task due to the interruption of alarm handling was observed.Displaying alarms on an integrated workstation supports alarm handling and consequently reduces disruptive effects on the primary task. The findings show that even small changes can reduce workload in a complex work environment like the operating room, resulting in improved patient safety.


2009 ◽  
Vol 37 (3) ◽  
pp. 173-178
Author(s):  
Eiharu MORIKAWA ◽  
Hidesato OIGAWA ◽  
Tatsuya SUGIYAMA ◽  
Hiroyuki NAKAJIMA ◽  
Takeshi OGURA ◽  
...  

2019 ◽  
Vol 14 (12) ◽  
pp. 2233-2243
Author(s):  
Johann Berger ◽  
Max Rockstroh ◽  
Erik Schreiber ◽  
Yukishige Yoshida ◽  
Jun Okamoto ◽  
...  

ACI Open ◽  
2018 ◽  
Vol 02 (01) ◽  
pp. e10-e20
Author(s):  
Raluca Dees ◽  
Angela Merzweiler ◽  
Gerd Schneider ◽  
Martin Kasparick ◽  
Lars Mündermann ◽  
...  

Background Digital operating rooms (ORs), when optimally designed and integrated, can reduce the complexity of the surgery suite. However, many integrated ORs are effectively isolated from other IT systems in the hospital because there is little or no connectivity with them. Within the German flagship project OR.NET, concepts and components were developed for a standard-based connection of the OR with hospital IT systems. Objectives The aim of this work was to implement and evaluate OR.NET concepts and components within the existing IT landscape of a German university hospital. This article describes and evaluates the implemented architecture and processes for connecting a demo OR to existing hospital IT systems at Heidelberg University Hospital. Methods For the design, establishment, and evaluation of standard-based connections of the demo OR with hospital IT systems, the iterative method “Design and Creation” with four iterations was applied. Results A generic and a concrete architecture for several standard-based connection concepts of the demo OR were developed. Furthermore, the concrete architecture was implemented and evaluated for its technical and clinical relevance. The main benefits of the project were the establishment of basic requisites for improving the efficiency within the OR, easier operation of medical devices as a result of harmonized human–machine interfaces, and providing additional data for improving healthcare. Conclusion OR.NET concepts for a standard-based connection of the OR with hospital IT systems have proven to be promising. They can serve as a reference for further integration scenarios in other hospitals.


2012 ◽  
Vol 33 (5) ◽  
pp. E12 ◽  
Author(s):  
Gazanfar Rahmathulla ◽  
Pablo F. Recinos ◽  
David E. Traul ◽  
Rafi Avitsian ◽  
Marisa Yunak ◽  
...  

Technological advances have made it possible to seamlessly integrate modern neuroimaging into the neurosurgical operative environment. This integration has introduced many new applications improving surgical treatments. One major addition to the neurosurgical armamentarium is intraoperative navigation and MRI, enabling real-time use during surgery. In the 1970s, the American College of Radiology issued safety guidelines for diagnostic MRI facilities. Until now, however, no such guidelines existed for the MRI-integrated operating room, which is a high-risk zone requiring standardized protocols to ensure the safety of both the patient and the operating room staff. The forces associated with the strong 1.5- and 3.0-T magnets used for MRI are potent and hazardous, creating distinct concerns regarding safety, infection control, and image interpretation. Authors of this paper provide an overview of the intraoperative MRI operating room, safety considerations, and a series of checklists and protocols for maintaining safety in this zero tolerance environment.


Sign in / Sign up

Export Citation Format

Share Document