Wall Shear Stress Measurements in Artificial Heart Valves with Hot-Film Probes

Author(s):  
W. Tillmann ◽  
G. Häußinger
Author(s):  
C. Ariyaratne ◽  
F. Wang ◽  
S. He ◽  
A. E. Vardy

Hot-wire and hot-film anemometry are widely used in steady flows for instantaneous velocity measurements, and their use has been extended to velocity and wall shear stress measurements in unsteady flows. The technique of hot-film anemometry relies on the Reynolds analogy which relates the diffusion of heat to the momentum exchange. The paper investigates the applicability of the analogy in linearly varying flows. The investigation is a combination of CFD analyses using the Transition SST model and experimental measurements. Results show that, in a linearly accelerating flow, while wall shear stress increases immediately upon the onset of acceleration, heat transfer indicates a relative lag in response. A quantitative analysis of the effects of flow parameters shows that the deviant behaviour is especially pronounced with increasing acceleration and/or reduced initial flow Reynolds number. The initial deviation can be predicted using a non-dimensional parameter based on turbulence timescales and acceleration rate, thereby providing a possible solution to correcting wall shear stress measurements using hot-film anemometry in fast accelerating flows.


1988 ◽  
Vol 16 (2) ◽  
pp. 235-238
Author(s):  
Subhashis Nandy ◽  
Alex Yefim Bekker ◽  
Gregory Allen Winchell ◽  
John Francis O'Riordan

Author(s):  
Christian Cierpka ◽  
Massimiliano Rossi ◽  
Christian J. Kähler

2004 ◽  
Vol 127 (2) ◽  
pp. 244-253 ◽  
Author(s):  
Steven W. Day ◽  
James C. McDaniel

Magnetically suspended left ventricular assist devices have only one moving part, the impeller. The impeller has absolutely no contact with any of the fixed parts, thus greatly reducing the regions of stagnant or high shear stress that surround a mechanical or fluid bearing. Measurements of the mean flow patterns as well as viscous and turbulent (Reynolds) stresses were made in a shaft-driven prototype of a magnetically suspended centrifugal blood pump at several constant flow rates (3–9L∕min) using particle image velocimetry (PIV). The chosen range of flow rates is representative of the range over which the pump may operate while implanted. Measurements on a three-dimensional measurement grid within several regions of the pump, including the inlet, blade passage, exit volute, and diffuser are reported. The measurements are used to identify regions of potential blood damage due to high shear stress and∕or stagnation of the blood, both of which have been associated with blood damage within artificial heart valves and diaphragm-type pumps. Levels of turbulence intensity and Reynolds stresses that are comparable to those in artificial heart valves are reported. At the design flow rate (6L∕min), the flow is generally well behaved (no recirculation or stagnant flow) and stress levels are below levels that would be expected to contribute to hemolysis or thrombosis. The flow at both high (9L∕min) and low (3L∕min) flow rates introduces anomalies into the flow, such as recirculation, stagnation, and high stress regions. Levels of viscous and Reynolds shear stresses everywhere within the pump are below reported threshold values for damage to red cells over the entire range of flow rates investigated; however, at both high and low flow rate conditions, the flow field may promote activation of the clotting cascade due to regions of elevated shear stress adjacent to separated or stagnant flow.


2019 ◽  
Vol 305 ◽  
pp. 16-21
Author(s):  
Nina Shokina ◽  
Andreas Bauer ◽  
Gabriel Teschner ◽  
Waltraud B. Buchenberg ◽  
Cameron Tropea ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document