centrifugal blood pump
Recently Published Documents


TOTAL DOCUMENTS

474
(FIVE YEARS 38)

H-INDEX

27
(FIVE YEARS 2)

Author(s):  
Seyed Ehsan Hosseini ◽  
Amir Keshmiri

Abstract Purpose Due to the importance of public health and economics, cardiovascular disease has become one of the most important debates and challenges for scientists. However, few studies have been done to address this challenge. The main objective of this document is to provide an optimal model to improve the performance of the left ventricular assist device and reduce costs. In this way, in the present study, the experimental and numerical procedures were developed to analyze the effects of the geometrical features and operational parameters on the performance of a centrifugal blood pump (CBP). Methods In order to achieve this aim, first, experimental tests were carried out to study the influence of the working fluid temperature and the rotational speed on the CBP. Subsequently, the performance of the CBP was assessed using computational fluid dynamics (CFD), and comparison was made against the experimental data. In addition, the influence of mounting an inducer on the overall performance of CBP was also investigated. Results Good agreement between the CFD and the data was obtained. The CFD results showed that increasing the fluid temperature and rotational speed leads to an increase in the hydraulic efficiency, pressure difference, and power. In addition, the reduction of the pressure difference and hydraulic efficiency with increasing the surface roughness was observed. While mounting an inducer on the pump did not significantly impact its overall performance, the highest value of the wall shear stress dropped moderately on the impeller and, therefore, unveiled the possibility of improving the performance of such designs.


Author(s):  
Ahmet Onder ◽  
Rafet Yapici ◽  
Omer Incebay

The use of substitute fluid with similar rheological properties instead of blood is important due to ethical concerns and high blood volume consumption in pump performance test before clinical applications. The performance of a centrifugal blood pump with hydrodynamic journal bearing is experimentally tested using Newtonian 40% aqueous glycerin solution (GS) and non-Newtonian aqueous xanthan gum solution of 600 ppm (XGS) as working fluids. Experiments are performed at four different rotational speeds which are 2700, 3000, 3300, and 3600 rpm; experiments using GS reach between 8.5% and 37.2% higher head curve than experiments using the XGS for every rotational speed. It was observed that as the rotational speed and flow rate increase, the head curve difference between GS and XGS decreases. This result can be attributed to the friction reduction effect when using XGS in experiments at high rotation speed and high flow rate. Moreover, due to different fluid viscosities, differences in hydraulic efficiency were observed for both fluids. This study reveals that the use of Newtonian fluids as working fluids is not sufficient to determine the actual performance of a blood pump, and the performance effects of non-Newtonian fluids are remarkably important in pump performance optimizations.


Machines ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 5
Author(s):  
André C. M. Cavalheiro ◽  
Diolino J. Santos Filho ◽  
Jônatas C. Dias ◽  
Aron J. P. Andrade ◽  
José R. Cardoso ◽  
...  

In patients with severe heart disease, the implantation of a ventricular assist device (VAD) may be necessary, especially in patients with an indication for heart transplantation. For this, the Institute Dante Pazzanese of Cardiology (IDPC) has developed an implantable centrifugal blood pump that will be able to help a diseased human heart to maintain physiological blood flow and pressure. This device will be used as a totally or partially implantable VAD. Therefore, performance assurance and correct specification of the VAD are important factors in achieving a safe interaction between the device and the patient’s behavior or condition. Even with reliable devices, some failures may occur if the pumping control does not keep up with changes in the patient’s behavior or condition. If the VAD control system has no fault tolerance and no system dynamic adaptation that occurs according to changes in the patient’s cardiovascular system, a number of limitations can be observed in the results and effectiveness of these devices, especially in patients with acute comorbidities. This work proposes the application of a mechatronic approach to this class of devices based on advanced control, instrumentation, and automation techniques to define a method to develop a hierarchical supervisory control system capable of dynamically, automatically, and safely VAD control. For this methodology, concepts based on Bayesian networks (BN) were used to diagnose the patient’s cardiovascular system conditions, Petri nets (PN) to generate the VAD control algorithm, and safety instrumented systems to ensure the safety of the VAD system.


2021 ◽  
pp. 039139882110525
Author(s):  
Akiko Oota-Ishigaki ◽  
Takashi Yamane ◽  
Daisuke Sakota ◽  
Ryo Kosaka ◽  
Osamu Maruyama ◽  
...  

Low-flow blood pumps rated under 1 L/min are emerging for new medical applications, such as hemofiltration in acute use. In those pumps, platelet adhesion and aggregation have to be carefully considered because of clogging risk in the filter part. To find an acceptable hemocompatibility that can be applied to low-flow centrifugal blood pump design, the platelet aggregation index, clogging on a micromesh filter, and the hemolysis index were investigated using a low-flow blood pump designed for hemofiltration use. We conducted circulation testing in vitro using fresh porcine blood and two centrifugal pumps with different impeller inlet shapes. The Negative Log Platelet Aggregation Threshold Index (NL-PATI), which reflects the ability of residual platelets to aggregate, and flow rate were measured during reflux for 60 min, and the Normalized Index of Hemolysis (NIH (g/20 min)) was calculated. In addition, blood cell clogging after reflux was observed on the micromesh filter by SEM, and the adhesion rate was calculated. Our results showed that the platelet clogging on the micromesh filter occurred when the average NL-PATI was greater than 0.28 and the average NIH (g/20 min) was greater than 0.01. In contrast, platelet clogging on the micromesh was suppressed when NL-PATI was less than 0.17 and the NIH (g/20 min) was less than 0.003. These values might be used as acceptable hemocompatibility of low-flow centrifugal blood pumps with suppressed platelet clogging for hemofiltration pumps.


2021 ◽  
Vol 12 ◽  
Author(s):  
Peng Wu ◽  
Wenjing Xiang ◽  
Chengke Yin ◽  
Shu Li

In recent years, blood pumps have become the bridge to heart transplantation for patients with heart failure. Portability and wearability of blood pumps should be considered to ensure patient satisfaction in everyday life. To date, the focus has been on the development of portable and wearable peripheral components, little attention has been paid to the portable and wearable performance of the blood pump itself. This study reported a novel design of a wearable and portable extracorporeal centrifugal blood pump. Based on an in-house centrifugal maglev blood pump, the wearable and portable blood pump was designed with parallel inlet and outlet pipes to improve the wearable performance. A ring cavity was set at the inlet to convert the circumferential velocity of the inlet pipe to an axial velocity. The hydraulic and hemolytic performance of the baseline and portable blood pumps were analyzed and compared. Compared with the baseline pump, the hydrodynamic and hemolytic performance of the portable pump has been maintained without serious degradation. The results of this study will improve the life quality of patients with heart failure, and enhance the clinical benefits of artificial heart.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Ignazio Condello ◽  
Giuseppe Santarpino ◽  
Giuseppe Filiberto Serraino ◽  
Pasquale Mastroroberto ◽  
Giuseppe Speziale ◽  
...  

Abstract Background Elevated plasma free hemoglobin is associated with multi-organ injury. In this context, minimally invasive extracorporeal technologies represent a way to reduce this complication following cardiac surgery. Methods We present a pilot study focused on plasma free hemoglobin levels in 40 patients undergoing isolated coronary artery bypass grafting (CABG). The same circuits for minimally invasive extracorporeal circulation (MiECC) were used in all patients. The ECMOLIFE magnetic levitation pump was used in the study group (n = 20), and the AP40 Affinity CP centrifugal blood pump was used in the control group (n = 20). Results In the immediate postoperative period, plasma free hemoglobin (PFH) and lactate dehydrogenase (LDH) were significantly lower in the study group than in the control group (10.6 ± 0.7 vs 19.9 ± 0.3 mg/dL, p = 0.034; and 99.16 ± 1.7 vs 139.17 ± 1.5 IU/L, p = 0.027, respectively). Moreover, patients treated with the magnetic levitation pump showed lower creatinine and indirect bilirubin (0.92 vs 1.29 mg/dL, p = 0.030 and 0.6 ± 0.4 vs 1.5 ± 0.9 mg/dL, p = 0.022, respectively) at 24 h after the procedure, and received fewer transfusions during the whole postoperative period (3 vs 9 red blood cell units (RBC), p = 0.017). Conclusion Our pilot study suggests that the use of magnetically levitated centrifugal pumps for extracorporeal circulation support is associated with a lower risk of hemolysis, though larger studies are warranted to confirm our results.


2021 ◽  
pp. 039139882110416
Author(s):  
Ge He ◽  
Jiafeng Zhang ◽  
Aakash Shah ◽  
Zachary B Berk ◽  
Lu Han ◽  
...  

Blood pumps have been increasingly used in mechanically assisted circulation for ventricular assistance and extracorporeal membrane oxygenation support or during cardiopulmonary bypass for cardiac surgery. However, there have always been common complications such as thrombosis, hemolysis, bleeding, and infection associated with current blood pumps in patients. The development of more biocompatible blood pumps still prevails during the past decades. As one of those newly developed pumps, the Breethe pump is a novel extracorporeal centrifugal blood pump with a hybrid magnetic and mechanical bearing with attempt to reduce device-induced blood trauma. To characterize the hydrodynamic and hemolytic performances of this novel pump and demonstrate its superior biocompatibility, we use a combined computational and experimental approach to compare the Breethe pump with the CentriMag and Rotaflow pumps in terms of flow features and hemolysis under an operating condition relevant to ECMO support (flow: 5 L/min, pressure head: ~350 mmHg). The computational results showed that the Breethe pump has a smaller area-averaged wall shear stress (WSS), a smaller volume with a scalar shear stress (SSS) level greater than 100 Pa and a lower device-generated hemolysis index compared to the CentriMag and Rotaflow pumps. The comparison of the calculated residence times among the three pumps indicated that the Breethe pump might have better washout. The experimental data from the in vitro hemolysis testing demonstrated that the Breethe pump has the lowest normalized hemolysis index (NIH) than the CentriMag and Rotaflow pumps. It can be concluded based on both the computational and experimental data that the Breethe pump is a viable pump for clinical use and it has better biocompatibility compared to the clinically accepted pumps.


Processes ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 1211
Author(s):  
Bo Huang ◽  
Miao Guo ◽  
Bin Lu ◽  
Qingyu Wu ◽  
Zhigang Zuo ◽  
...  

Centrifugal blood pumps have provided a powerful artificial support system for patients with vascular diseases. In the design process, geometrical optimization is usually needed to acquire a more biocompatible model for clinical uses. In the current paper, we propose a method for multi-objective optimization concerning both the hydraulic and the hemolytic performances of the pump based on the near-orthogonal array in which the traditional hemolysis index (HI) is replaced with the maximum scalar shear stress criteria to reduce the computation load. The method is demonstrated with the optimization of an extracorporeal centrifugal blood pump with an unshrouded impeller. CFD studies on the original and nine modified pump models are carried out. The calculated hydraulic performances of the optimized model are also compared against the experiments for validation of the numeric method, with an error of 3.6% at the original design point. The resulting blood pump with low maximum scalar shear stress (132.2 Pa) shows a low degree of calculated HI (1.69 × 10−3).


Author(s):  
Mohamad Sadeq Karimi ◽  
Pooya Razzaghi ◽  
Mehrdad Raisee ◽  
Patrick Hendrick ◽  
Ahmad Nourbakhsh

2021 ◽  
pp. 039139882110237
Author(s):  
Ahmet Onder ◽  
Omer Incebay ◽  
Muhammed Arif Sen ◽  
Rafet Yapici ◽  
Mete Kalyoncu

Optimization studies on blood pumps that require complex designs are gradually increasing in number. The essential design criteria of centrifugal blood pump are minimum shear stress with maximal efficiency. The geometry design of impeller sidewall gaps (blade tip clearance, axial gap, radial gap) is highly effective with regard to these two criteria. Therefore, unlike methods such as trial and error, the optimal dimensions of these gaps should be adjusted via a heuristic method, giving more effective results. In this study, the optimal gaps that can ensure these two design criteria with The Bees Algorithm (BA), which is a population-based heuristic method, are investigated. Firstly, a Computational Fluid Dynamics (CFD) analysis of sample pump models, which are selected according to the orthogonal array and pre-designed with different gaps, are performed. The dimensions of the gaps are optimized through this mathematical model. The simulation results for the improved pump model are nearly identical to those predicted by the BA. The improved pump model, as designed with the optimal gap dimensions so obtained, is able to meet the design criteria better than all existing sample pumps. Thanks to the optimal gap dimensions, it has been observed that compared to average values, it has provided a 42% reduction in aWSS and a 20% increase in efficiency. Moreover, original an approach to the design of impeller sidewall gaps was developed. The results show that computational costs have been significantly reduced by using the BA in blood pump geometry design.