Optimization of Hopper System of Pump Unit on Automotive Chassis

2021 ◽  
pp. 93-105
Author(s):  
Alexey Lebedev ◽  
Sergey Kireev ◽  
Marina Korchagina ◽  
Valentin Stepanov
Keyword(s):  
2013 ◽  
Vol 753-755 ◽  
pp. 1727-1730
Author(s):  
Yue Zhang ◽  
You Hong Xiao ◽  
Jun Weng ◽  
Wan You Li

In this paper, the vibration of a three screw pump was studied. Firstly the vibration response of the pump was tested. Then the FE model of the pump was constructed and the modals of it were calculated. The exactness of the result was confirmed by the testing modals and the reasonable of the FE model was verified at the same time. Finally, the force acted on rotors due to pressure was calculated by the mathematical method of surface integral. The force was loaded on the FE model and the force response was predicted, which represented the basic vibration of the screw pump. Based on the work above, the vibration spectrum of the screw pump was analyzed.


2011 ◽  
Vol 121-126 ◽  
pp. 2162-2166
Author(s):  
Yan Mei Meng ◽  
Hai Feng Pang ◽  
Ying Ning Hu ◽  
Quan Zhou ◽  
Dao Yang Li ◽  
...  

This paper describes the research and implementation of ground source heat pump unit remote real-time monitoring system, researches in remote real-time monitoring system's overall design, hardware design, software design and implementation of OPC communication. The host computer takes advantage of the human-computer interaction interface of configuration software to achieve the remote real-time monitoring for ground source heat pump unit's running state; the lower computer uses data collector to intensively collect the data which is measured by field measuring instruments, and to achieve remote data transmission based on Ethernet, and then to carry out the communication between the host computer and the lower computer via OPC technology. The results show that the system achieves remote real-time monitoring of ground source heat pump unit, and is stable, easy to operate and provides a reliable basis for the actual energy saving effect's evaluation of ground source heat pump system.


2020 ◽  
Vol 23 (2) ◽  
pp. 48-51
Author(s):  
V. KONDRATENKO ◽  
◽  
V. KALYNYCHENKO ◽  

Mine drainage systems, which are used at the main drainage of mining enterprises, have a drive capacity of up to 1600kW. To reduce non-productive energy losses, as well as for the continuous operation of the mining company, mine pumps must be energy efficient and reliable. Analysis of downtime of drainage systems shows that the weak point is the unloading device. This fact can lead not only to the failure of the pumping unit, but also to possible prolonged downtime of the mine. The main disadvantage of the existing disk unloading devices of mine pumps is their low reliability and low service life, due to the rapid wear of the components of the unloading unit. The most vulnerable elements of the unloading device are the unloading rings. The need for frequent replacement and adjustment of the elements of the discharge unit is associated with disassembly and assembly of the pump directly in the pump chamber. Such actions require significant costs of unproductive manual labor of service personnel, and rapid wear of parts of the unloading device necessitates their constant replenishment. Malfunctions in the unloading device can cause significant pump failures. To increase the reliability and energy efficiency of mine drainage systems, the method of control of the unloading device was used. During the experimental studies it was found that cavitation phenomena during the operation of pumping units are absent and, accordingly, can not be the cause of wear of the elements of the unloading unit. When the pumps are operating in steady state, the displacement of the rotors was monitored for 3-4 hours on each pump unit. After data processing, it was obtained that the wear of the surface of the unloading rings occurs at a rate of 0.05-0.15mm in one hour. To determine the wear of the rings of unloading during start-up - stop of the pump, at first the indicators of measuring devices at the established mode of operation of the pump unit were fixed. Then the pump was turned off and on again. After starting the pump unit, we made sure that the operating mode of the unloading device did not change and compared the readings of the shaft position indicator before stopping and after starting the pump. From the measurements made it followed that stopping and starting the pump does not lead to noticeable wear of the unloading device. Therefore, it can be assumed that mainly the wear of the discharge rings occurs during the steady operation of the pump unit.


2017 ◽  
Vol 204 ◽  
pp. 679-689 ◽  
Author(s):  
Mengjie Song ◽  
Xiangguo Xu ◽  
Ning Mao ◽  
Shiming Deng ◽  
Yingjie Xu

2012 ◽  
Vol 608-609 ◽  
pp. 1241-1245
Author(s):  
Wei Qiu ◽  
Li Zhang ◽  
Qing Rong liu

This paper analyses the energy consumption of water source heat pump, shows that the performance coefficient of water source heat pump unit is directly related to the temperature of water resources, and discusses the feasibility of central heating by recovering condensing heat of power plant using water source heat pump unit. It analyzes the energy saving benefit of water source heat pump unit is significant compared with traditional heating. Using the technology recovers waste heat of power plant, which can not only decrease the energy waste on the direct discharge of waste heat and water, but at the same time, it is a new air conditioning system without environmental pollution.


Sign in / Sign up

Export Citation Format

Share Document