Optimal Design of Control System for Ground Source Heat Pump Unit

Author(s):  
Xiaomei Jiang ◽  
Michael Namokel ◽  
Chaobin Hu ◽  
Ran Tian
2011 ◽  
Vol 121-126 ◽  
pp. 2162-2166
Author(s):  
Yan Mei Meng ◽  
Hai Feng Pang ◽  
Ying Ning Hu ◽  
Quan Zhou ◽  
Dao Yang Li ◽  
...  

This paper describes the research and implementation of ground source heat pump unit remote real-time monitoring system, researches in remote real-time monitoring system's overall design, hardware design, software design and implementation of OPC communication. The host computer takes advantage of the human-computer interaction interface of configuration software to achieve the remote real-time monitoring for ground source heat pump unit's running state; the lower computer uses data collector to intensively collect the data which is measured by field measuring instruments, and to achieve remote data transmission based on Ethernet, and then to carry out the communication between the host computer and the lower computer via OPC technology. The results show that the system achieves remote real-time monitoring of ground source heat pump unit, and is stable, easy to operate and provides a reliable basis for the actual energy saving effect's evaluation of ground source heat pump system.


2012 ◽  
Vol 42 ◽  
pp. 111-117 ◽  
Author(s):  
Hangseok Choi ◽  
Honghyun Cho ◽  
Jong Min Choi

2013 ◽  
Vol 732-733 ◽  
pp. 152-155
Author(s):  
Qiang Wang ◽  
Zhao Lei Ding ◽  
Hai Yun Wang ◽  
Wen Chao Lv

A grey box model of screw ground source heat pump unit has been established and operating characteristics of the unit using R22 refrigerants were simulated. The effects on refrigerating capacity, heating capacity, power consumption of the compressor and COP on conditions of cooling and heating have been analyzed with different inlet water temperature of evaporator and inlet water temperature of condenser. Results show that main factor which affecting COP of heat pump unit is inlet water temperature of condenser. The change of refrigerating capacity and heating capacity are mainly caused by inlet water temperature of evaporator. Measures can be done to decrease the inlet water temperature of condenser when the unit operates for a long time and to increase inlet water temperature of evaporator on very hot or very cold conditions.


2014 ◽  
Vol 953-954 ◽  
pp. 698-704 ◽  
Author(s):  
Zhen Zhao Liu ◽  
Bo Song ◽  
Ying Ning Hu ◽  
Shan Shan Hu

For two practical engineering case in a University in Guilin, this paper mainly introduces the performance of sewage-source heat pump and ground source heat pump and compare the running status in two kinds of system. The studies have shown that the sewage source heat pump unit COP at about 3.9, the system COP at about 3.3, ground source heat pump unit COP at about 4.5, the system COP at about 3.4.


2022 ◽  
Vol 308 ◽  
pp. 118370
Author(s):  
Ellen Nordgård-Hansen ◽  
Nand Kishor ◽  
Kirsti Midttømme ◽  
Vetle Kjær Risinggård ◽  
Jan Kocbach

2018 ◽  
Author(s):  
Takao Katsura ◽  
Yutaka Shoji ◽  
Yoshiki Miyashita ◽  
Katsunori Nagano ◽  
Yasushi Nakamura

2020 ◽  
Vol 131 ◽  
pp. 110001 ◽  
Author(s):  
Zhenjun Ma ◽  
Lei Xia ◽  
Xuemei Gong ◽  
Georgios Kokogiannakis ◽  
Shugang Wang ◽  
...  