Microstructure and Corrosion Behavior of Bioabsorbable Polymer Polylactic Acid-Polycaprolactone Reinforced by Magnesium-Zinc Alloy for Biomedical Application

Author(s):  
Aprilia Erryani ◽  
Alfiyah Rahmah ◽  
Talitha Asmaria ◽  
Franciska Pramuji Lestari ◽  
Ika Kartika
2013 ◽  
Vol 100 ◽  
pp. 188-191 ◽  
Author(s):  
Xiaobo Zhang ◽  
Zhixin Ba ◽  
Zhangzhong Wang ◽  
Xiancong He ◽  
Chong Shen ◽  
...  

2019 ◽  
Vol 25 (29) ◽  
pp. 71-79
Author(s):  
Masatoshi Sakairi ◽  
Akihiro Kageyama ◽  
Tatsuya Kikuchi

2010 ◽  
Vol 55 (10) ◽  
pp. A194.E1811
Author(s):  
Hitomi Hagiwara ◽  
Masashige Sasaki ◽  
Yoshiaki Hiraishi ◽  
Hisako Terao ◽  
Junji Kimura ◽  
...  

2019 ◽  
Vol 1279 ◽  
pp. 012031
Author(s):  
Fatima Alaa Adnan ◽  
Niveen Jamal Abdulkader ◽  
Mohammed Salab Hamza

2018 ◽  
Vol 6 (2) ◽  
pp. 026539 ◽  
Author(s):  
Cheng-Jie Li ◽  
Hong-Fei Sun ◽  
Shuang Cheng ◽  
Hong-Mei Tan ◽  
Tian-Hong He ◽  
...  

1986 ◽  
Author(s):  
T. R. Roberts ◽  
D. J. Robbins ◽  
D. M. Smith ◽  
J. Zappia

2009 ◽  
Vol 255 (22) ◽  
pp. 9124-9131 ◽  
Author(s):  
Y.M. Wang ◽  
F.H. Wang ◽  
M.J. Xu ◽  
B. Zhao ◽  
L.X. Guo ◽  
...  

2015 ◽  
Vol 100 (11-12) ◽  
pp. 1408-1413 ◽  
Author(s):  
Mitsuo Miyazawa ◽  
Masayasu Aikawa ◽  
Katsuya Okada ◽  
Yukihiro Watanabe ◽  
Kojun Okamoto ◽  
...  

The aim of this study was to investigate whether an artificial bile duct made of bioabsorbable polymer could serve as a substitute for narrowed portions of the bile duct. The experiments were performed using hybrid pigs (n = 11). After laparotomy under general anesthesia, the extrahepatic bile duct was identified and ligated around the confluence with the cystic duct. A week later, repeat laparotomy was performed on the animals, and the bile duct on the hepatic side of the ligature was resected. The cut end was connected to the duodenum using a bioabsorbable artificial bile duct fabricated from a copolymer of polycaprolactone and polylactic acid fibers. The grafts were recovered for gross, histologic, and blood chemical studies at 4 months after the surgery. All recipient pigs survived until they were humanely killed for collection of the implants. A week of ligation of the extrahepatic bile duct dilated the duct to approximately 1 cm in diameter and increased total bilirubin. Total bilirubin had returned to the pre-implantation level in all animals at 4 months post implantation. Examinations of the grafts revealed complete freedom of stricture and the regeneration of a neo-bile duct of approximately 1 cm in diameter from the graft site in 10 of 11 animals. Gross observation of the graft from the 1 remaining animal revealed stricture at the anastomosis site and poor bile duct epithelization. We have concluded that this bioabsorbable polymer bile duct can serve as a replacement for narrowed portions of the bile duct.


Sign in / Sign up

Export Citation Format

Share Document