Effect of slice orientation in 3D magnetic resonance angiography (MRA) of the supra-aortic arteries

1991 ◽  
Vol 1 (2) ◽  
pp. 158-164 ◽  
Author(s):  
G. M. Bongartz ◽  
Th. Vestring ◽  
Cl. Drews ◽  
W. Krings ◽  
P. E. Peters
VASA ◽  
2005 ◽  
Vol 34 (3) ◽  
pp. 181-185 ◽  
Author(s):  
Westhoff-Bleck ◽  
Meyer ◽  
Lotz ◽  
Tutarel ◽  
Weiss ◽  
...  

Background: The presence of a bicuspid aortic valve (BAV) might be associated with a progressive dilatation of the aortic root and ascending aorta. However, involvement of the aortic arch and descending aorta has not yet been elucidated. Patients and methods: Magnetic resonance angiography (MRA) was used to assess the diameter of the ascending aorta, aortic arch, and descending aorta in 28 patients with bicuspid aortic valves (mean age 30 ± 9 years). Results: Patients with BAV, but without significant aortic stenosis or regurgitation (n = 10, mean age 27 ± 8 years, n.s. versus control) were compared with controls (n = 13, mean age 33 ± 10 years). In the BAV-patients, aortic root diameter was 35.1 ± 4.9 mm versus 28.9 ± 4.8 mm in the control group (p < 0.01). The diameter of the ascending aorta was also significantly increased at the level of the pulmonary artery (35.5 ± 5.6 mm versus 27.0 ± 4.8 mm, p < 0.001). BAV-patients with moderate or severe aortic regurgitation (n = 18, mean age 32 ± 9 years, n.s. versus control) had a significant dilatation of the aortic root, ascending aorta at the level of the pulmonary artery (41.7 ± 4.8 mm versus 27.0 ± 4.8 mm in control patients, p < 0.001) and, furthermore, significantly increased diameters of the aortic arch (27.1 ± 5.6 mm versus 21.5 ± 1.8 mm, p < 0.01) and descending aorta (21.8 ± 5.6 mm versus 17.0 ± 5.6 mm, p < 0.01). Conclusions: The whole thoracic aorta is abnormally dilated in patients with BAV, particularly in patients with moderate/severe aortic regurgitation. The maximum dilatation occurs in the ascending aorta at the level of the pulmonary artery. Thus, we suggest evaluation of the entire thoracic aorta in patients with BAV.


VASA ◽  
2016 ◽  
Vol 45 (2) ◽  
pp. 149-154 ◽  
Author(s):  
Jie Li ◽  
Lei Feng ◽  
Jiangbo Li ◽  
Jian Tang

Abstract. Background: The aim of this meta-analysis was to evaluate the diagnostic accuracy of magnetic resonance angiography (MRA) for acute pulmonary embolism (PE). Methods: A systematic literature search was conducted that included studies from January 2000 to August 2015 using the electronic databases PubMed, Embase and Springer link. The summary receiver operating characteristic (SROC) curve, sensitivity, specificity, positive likelihood ratios (PLR), negative likelihood ratios (NLR), and diagnostic odds ratio (DOR) as well as the 95 % confidence intervals (CIs) were calculated to evaluate the diagnostic accuracy of MRA for acute PE. Meta-disc software version 1.4 was used to analyze the data. Results: Five studies were included in this meta-analysis. The pooled sensitivity (86 %, 95 % CI: 81 % to 90 %) and specificity (99 %, 95 % CI: 98 % to 100 %) demonstrated that MRA diagnosis had limited sensitivity and high specificity in the detection of acute PE. The pooled estimate of PLR (41.64, 95 % CI: 17.97 to 96.48) and NLR (0.17, 95 % CI: 0.11 to 0.27) provided evidence for the low missed diagnosis and misdiagnosis rates of MRA for acute PE. The high diagnostic accuracy of MRA for acute PE was demonstrated by the overall DOR (456.51, 95 % CI: 178.38 - 1168.31) and SROC curves (AUC = 0.9902 ± 0.0061). Conclusions: MRA can be used for the diagnosis of acute PE. However, due to limited sensitivity, MRA cannot be used as a stand-alone test to exclude acute PE.


Sign in / Sign up

Export Citation Format

Share Document