Fibrinolytic activity of the blood during transient coronary insufficiency in rats

1987 ◽  
Vol 104 (5) ◽  
pp. 1532-1534
Author(s):  
A. V. Pleshanov ◽  
P. F. Litvitskii ◽  
E. I. Alekseeva ◽  
T. B. Nefedova ◽  
I. N. Bokarev
1983 ◽  
Vol 95 (1) ◽  
pp. 31-34 ◽  
Author(s):  
P. F. Litvitskii ◽  
G. A. Yakunin ◽  
L. A. Lavrova ◽  
A. V. Pleshanov ◽  
A. Ya. Smolyanitskii

1984 ◽  
Vol 97 (1) ◽  
pp. 42-45
Author(s):  
L. F. Litvitskii ◽  
L. I. Vinnitskii ◽  
I. L. Zhidkov ◽  
M. B. Zuev ◽  
N. T. Vorob'eva

1988 ◽  
Vol 59 (02) ◽  
pp. 299-303 ◽  
Author(s):  
Grazia Nicoloso ◽  
Jacques Hauert ◽  
Egbert K O Kruithof ◽  
Guy Van Melle ◽  
Fedor Bachmann

SummaryWe analyzed fibrinolytic parameters in 20 healthy men and 20 healthy women, aged from 25 to 59, before and after 10 and 20 min venous occlusion. The 10 min post-occlusion fibrinolytic activity measured directly in diluted unfractionated plasma by a highly sensitive 125I-fibrin plate assay correlated well with the activity of euglobulins determined by the classical fibrin plate assay (r = 0.729), but pre-stasis activities determined with these two methods did not correlate (r = 0.084). The enhancement of fibrinolytic activity after venous occlusion was mainly due to an increase of t-PA in the occluded vessels (4-fold increase t-PA antigen after 10 min and 8-fold after 20 min venous occlusion). Plasminogen activator inhibitor (PAI) activity and plasminogen activator inhibitor 1 (PAI-1)1 antigen levels at rest showed considerable dispersion ranging from 1.9 to 12.4 U/ml, respectively 6.9 to 77 ng/ml. A significant increase of PAI-1 antigen levels was observed after 10 and 20 min venous occlusion. At rest no correlation was found between PAI activity or PAI-1 antigen levels and the fibrinolytic activity measured by 125I-FPA. However, a high level of PAI-1 at rest was associated with a high prestasis antigen level of t-PA and a low fibrinolytic response after 10 min of venous stasis. Since the fibrinolytic response inversely correlated with PAI activity at rest, we conclude that its degree depends mainly on the presence of free PAI.


1991 ◽  
Vol 66 (03) ◽  
pp. 292-294 ◽  
Author(s):  
K K Hampton ◽  
M A Chamberlain ◽  
D K Menon ◽  
J A Davies

SummaryCoagulation and fibrinolytic activities were studied in 18 subjects with Behçet's disease and compared with results from 14 matched control patients suffering from sero-negative arthritis. Significantly higher plasma concentrations (median and range) were found in Behçet's patients for the following variables: fibrinogen 3.7 (1.7-6.9) vs 3.0 (2.0-5.1) g/1, p <0.05; von Willebrand factor antigen, 115 (72-344) vs 74 (60-119)%, p <0.002; plasminogen activator activity (106/ECLT2) 219 (94-329) vs 137 (78-197) units, p <0.002; tissue plasminogen activator inhibitor (t-PA-I) activity, 9.1 (5.5-19.3) vs 5.1 (1.8-12.0) IU/ml, p <0.002; and PAI-1 antigen, 13.9 (4.5-20.9) vs 6.4 (2.4-11.1) ng/ml, p <0.002. Protein C antigen was significantly lower: 97 (70-183) vs 126 (96-220)%, p <0.02. No differences were observed in antithrombin III activity or antigen, factor VIII coagulant activity, fibrinopeptides A and Bβ15-42, plasminogen, α-2-antiplasmin, functional and immunological tissue-plasminogen activator, thrombin-antithrombin complexes and D-dimer. Levels of tissue plasminogen activator inhibitor (activity and antigen) correlated with disease activity while fibrinogen and von Willebrand factor concentrations did not. Seven of the 18 subjects with Behçet's disease had suffered thrombotic events but it was not possible to distinguish these from the 11 patients without thrombosis using the assays performed. The results suggest the abnormal fibrinolytic activity in Behçet's disease is due to increased inhibition of tissue plasminogen activator. No abnormality of coagulation or fibrinolytic activity specific to Behçet's disease was detected.


Sign in / Sign up

Export Citation Format

Share Document