Impedance cardiography: the reproducibility of stroke volume measurements under conditions of mass examination

1978 ◽  
Vol 73 (6) ◽  
pp. 627-636 ◽  
Author(s):  
C. Stick ◽  
R. Büchsel

Impedance Cardiography (ICG) is a noninvasive method for indirect measurement of stroke volume, monitoring the cardiac output and observing the other hemodynamic parameters by the blood volume changes in the body. The blood volume changes inside a certain body segment due to a number of physiological processes are extracted in the form of the impedance variations of the body segment. The ICG analysis provides the heart stroke volume in sudden cardiac arrest. In the clinical environment desired ICG signals are influenced by several physiological and non-physiological artifacts.As these artifacts are not stationary in nature, we proposed adaptive filtering techniques to eliminate the artifacts. In this paper we used Least Mean Square (LMS), Least Mean Fourth (LMF), Median LMS (MLMS), Leaky LMS (LLMS), and Dead Zone (DZLMS) adaptive techniques to eliminate artifacts from the desired signals. Several adaptive signal enhancement units (ASEUs) are developed based on these adaptive techniques, and evaluated on the real ICG signal components. The ability of these algorithms is evaluated by performing the experiments to eliminate the various artifacts such as sinusoidal artifacts (SA), respiration artifacts (RA), muscle artifacts (MA) and electrode artifacts (EA). Among these techniques, the DZLMS based ASEU performs better in the filtering process. The signal to noise ratio improvement (SNRI) for this algorithm is calculated as 11.9140 dB, 7.3657 dB, 10.4060 dB and 10.5125 dB respectively for SA, RA, MA and EA. Hence, the DZLMS based ASEUs are well suitable for ICG filtering in the real time health care monitoring systems.


Shock ◽  
2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Ryoung Eun Ko ◽  
Geuk Young Jang ◽  
Chi Ryang Chung ◽  
Jin Young Lee ◽  
Tong In Oh ◽  
...  

2020 ◽  
Vol 128 (5) ◽  
pp. 1146-1152
Author(s):  
Cara H. Y. Cheung ◽  
May L. Khaw ◽  
Victor C. W. Tam ◽  
Michael T. C. Ying ◽  
Shara W. Y. Lee

The use of impedance cardiography to monitor physiological changes in sports is rarely reported. Using head-up tilt test, we evaluated a portable noninvasive impedance cardiography device (PhysioFlow) by comparing it with a reference Doppler monitor (USCOM). Accuracy in tracking hemodynamic changes deteriorated with higher tilt, implying a gravitational influence on its performance. Stroke volume measurements were overestimated, but the changes were underestimated. Despite its convenient physical features, the suitability of PhysioFlow for sports use is questionable.


Sign in / Sign up

Export Citation Format

Share Document