scholarly journals Suspension button constructs restore posterior knee laxity in solid tibial avulsion of the posterior cruciate ligament

Author(s):  
Philipp Forkel ◽  
Louis Buchmann ◽  
Jan J. Lang ◽  
Rainer Burgkart ◽  
Andreas B. Imhoff ◽  
...  

Abstract Purpose Dislocated tibial avulsions of the posterior cruciate ligament (PCL) require surgical intervention. Several arthroscopic strategies are options to fix the fragment and restore posterior laxity, including two types of suspension button devices: adjustable (self-locking) and rigid knotted systems. Our hypothesis was that a rigid knotted button construct has superior biomechanical properties regarding laxity restoration compared with an adjustable system. Both techniques were compared with standard screw fixation and the native PCL. Methods Sixty porcine knees were dissected. The constructs were tested for elongation, stiffness, yield force, load to failure force, and failure mode in a material testing machine. Group N (native, intact PCL) was used as a control group. In group DB (Dogbone™), TR (Tightrope™), and S (screw), a standardized block osteotomy with the osteotomized fragment attached to the PCL was set. The DB and TR groups simulated using a suspension button system with either a rigid knotted (DB) or adjustable system (TR). These groups were compared to a screw technique (S) simulating antegrade screw fixation from posterior. Results Comparing the different techniques (DB, TR, S), no significant elongation was detected; all techniques achieved a sufficient posterior laxity restoration. Significant elongation in the DB and TR group was detected compared with the native PCL (N). In contrast, screw fixation did not lead to significant elongation. The stiffness, yield load, and load to failure force did not differ significantly between the techniques. None of the techniques reached the same level of yield load and load to failure force as the intact state. Conclusion Arthroscopic suspension button techniques sufficiently restore the posterior laxity and gain a comparable construct strength as an open antegrade screw fixation.

2021 ◽  
pp. 036354652110130
Author(s):  
Stefano Nuccio ◽  
Luciana Labanca ◽  
Jacopo Emanuele Rocchi ◽  
Pier Paolo Mariani ◽  
Paola Sbriccoli ◽  
...  

Background: The acute effects of exercise on anterior knee laxity (AKL) and anterior knee stiffness (AKS) have been documented in healthy participants, but only limited evidence has been provided for athletes cleared to return to sports after anterior cruciate ligament (ACL) reconstruction (ACLR). Purpose/Hypothesis: The purpose was to determine if 45 minutes of a soccer match simulation lead to acute changes in AKL and AKS in soccer players returning to sport within 12 months after ACLR. We hypothesized that the reconstructed knee of the ACLR group would exhibit an altered response to sport-specific exercise. Study Design: Controlled laboratory study. Methods: A total of 13 soccer players cleared to return to sport after ACLR and 13 healthy control soccer players matched for age, physical activity level, limb dominance, and anthropometric characteristics were recruited. To assess the effects of a standardized soccer match simulation (Soccer Aerobic Field Test [SAFT45]) on AKL and AKS, an arthrometric evaluation was carried out bilaterally before and immediately after SAFT45. To conduct a comprehensive examination of the force-displacement curve, the absolute and side-to-side difference (SSD) values of both AKL and AKS were extracted at 67, 134, and 200 N. Results: The ACLR and control groups showed similar AKL and AKS at baseline ( P > .05). In response to SAFT45, laxity increased bilaterally at all force levels by 14% to 17% only in the control group ( P < .025). Similarly, AKS at 134 and 200 N decreased in response to SAFT45 only in the control group (10.5% and 20.5%, respectively; P < .025). After SAFT45, the ACLR group had 1.9 and 2.5 times higher SSDs of AKS at 67 and 134 N compared with the control group, respectively ( P < .025), as well as a 1.9 times higher SSD of AKS at 134 N compared with baseline ( P = .014). Conclusion: Soccer players at the time of return to sport after ACLR showed an altered mechanical response to a sport-specific match simulation consisting of bilaterally unchanged AKL and AKS. Clinical Relevance: Soccer players showing altered AKL and AKS in response to exercise after ACLR may not be ready to sustain their preinjury levels of sport, thus potentially increasing the risk of second ACL injuries.


2013 ◽  
Vol 22 (9) ◽  
pp. 2040-2047 ◽  
Author(s):  
M. Ettinger ◽  
M. Petri ◽  
K. T. Haag ◽  
S. Brand ◽  
A. Dratzidis ◽  
...  

2009 ◽  
Vol 37 (8) ◽  
pp. 1554-1563 ◽  
Author(s):  
Braden C. Fleming ◽  
Kurt P. Spindler ◽  
Matthew P. Palmer ◽  
Elise M. Magarian ◽  
Martha M. Murray

Background The outcome of anterior cruciate ligament (ACL) reconstruction is variable, and many patients have increased joint laxity postoperatively. Hypothesis Placement of a collagen-platelet composite (CPC) around the graft at the time of ACL reconstruction decreases postoperative knee laxity and improves the structural properties of the graft compared with standard ACL reconstruction. Study Design Controlled laboratory study. Methods Thirteen immature pigs underwent unilateral ACL reconstruction with a bone–patellar tendon–bone allograft. In 6 pigs, a standard allograft was used to reconstruct the ACL. In 7 pigs, a CPC was placed around the allograft. After 15 weeks of healing, the animals were euthanized, and the anterior-posterior (AP) knee laxity and structural properties of the graft were measured. Qualitative histology of the grafts was also performed. Results The AP laxity values of the reconstructed knees, normalized to the contralateral control, were significantly reduced by 28% and 57% at 60° and 90° of knee flexion, respectively, with the addition of CPC (P <. 001). Significant improvements in the graft structural properties were also found; the normalized yield (P =. 044) and maximum failure loads (P =. 025) of the CPC group were 60% higher than the standard ACL-reconstructed group. Although cellular and vessel infiltration were observed in the grafts of both groups, regions of necrosis were present only in the standard ACL-reconstructed group. Conclusion These data demonstrate that the application of CPC at the time of ACL reconstruction improves the structural properties of the graft and reduces early AP knee laxity in the porcine model after 15 weeks of healing. Clinical Relevance Application of a CPC to an ACL graft at the time of surgery decreased knee laxity and increased the structural properties of the graft after 15 weeks of healing.


2019 ◽  
Vol 101-B (9) ◽  
pp. 1058-1062
Author(s):  
K. S. R. van Kuijk ◽  
M. Reijman ◽  
S. M. A. Bierma-Zeinstra ◽  
J. H. Waarsing ◽  
D. E. Meuffels

Aims Little is known about the risk factors that predispose to a rupture of the posterior cruciate ligament (PCL). Identifying risk factors is the first step in trying to prevent a rupture of the PCL from occurring. The morphology of the knee in patients who rupture their PCL may differ from that of control patients. The purpose of this study was to identify any variations in bone morphology that are related to a PCL. Patients and Methods We compared the anteroposterior (AP), lateral, and Rosenberg view radiographs of 94 patients with a ruptured PCL to a control group of 168 patients matched by age, sex, and body mass index (BMI), but with an intact PCL after a knee injury. Statistical shape modelling software was used to assess the shape of the knee and determine any difference in anatomical landmarks. Results We found shape variants on the AP and Rosenberg view radiographs to be significantly different between patients who tore their PCL and those with an intact PCL after a knee injury. Overall, patients who ruptured their PCL have smaller intercondylar notches and smaller tibial eminences than control patients. Conclusion This study shows that differences in the shape of the knee are associated with the presence of a PCL rupture after injury. A smaller and more sharply angled intercondylar notch and a more flattened tibial eminence are related to PCL rupture. This suggests that the morphology of the knee is a risk factor for sustaining a PCL rupture. Cite this article: Bone Joint J 2019;101-B:1058–1062.


2016 ◽  
Vol 8 (2) ◽  
Author(s):  
Marco Ezechieli ◽  
Hanna Meyer ◽  
Arne Lucas ◽  
Patrick Helmecke ◽  
Christoph Becher ◽  
...  

Magnesium-based interference screws may be an alternative in anterior/posterior cruciate ligament reconstruction. The well-known osteoconductive effects of biodegradable magnesium alloys may be useful. It was the purpose of this study to evaluate the biomechanical properties of a magnesium based interference screw and compare it to a standard implant. A MgYREZr-alloy interference screw and a standard implant (Milagro®; De Puy Mitek, Raynham, MA, USA) were used for graft fixation. Specimens were placed into a tensile loading fixation of a servohydraulic testing machine. Biomechanical analysis included pretensioning of the constructs at 20 N for 1 min following cyclic pretensioning of 20 cycles between 20 and 60 N. Biomechanical elongation was evaluated with cyclic loading of 1000 cycles between 50 and 200 N at 0.5 Hz. Maximum load to failure was 511.3±66.5 N for the Milagro® screw and 529.0±63.3 N for magnesium-based screw (ns, P=0.57). Elongations after preload, during cyclical loading and during failure load were not different between the groups (ns, P&gt;0.05). Stiffness was 121.1±13.8 N/mm for the magnesiumbased screw and 144.1±18.4 for the Milagro® screw (ns, P=0.32). MgYREZr alloy interference screws show comparable results in biomechanical testing to standard implants and may be an alternative for anterior cruciate reconstruction in the future.


PLoS ONE ◽  
2015 ◽  
Vol 10 (5) ◽  
pp. e0127293 ◽  
Author(s):  
Yu-Shu Lai ◽  
Wen-Chuan Chen ◽  
Chang-Hung Huang ◽  
Cheng-Kung Cheng ◽  
Kam-Kong Chan ◽  
...  

Author(s):  
J. Glasbrenner ◽  
M. Fischer ◽  
M. J. Raschke ◽  
T. Briese ◽  
M. Müller ◽  
...  

Abstract Introduction The object of this study was to evaluate the primary stability of tibial interference screw (IFS) fixation in single-stage revision surgery of the anterior cruciate ligament (ACL) in the case of recurrent instability after ACL repair with dynamic intraligamentary stabilization (DIS), dependent on the implant position during DIS. Materials and methods Tibial aperture fixation in ACL reconstruction (ACL-R) was performed in a porcine knee model using an IFS. Native ACL-R was performed in the control group (n = 15). In the intervention groups DIS and subsequent implant removal were performed prior to single-stage revision ACL-R. A distance of 20 mm in group R-DIS1 (n = 15) and 5 mm in group R-DIS2 (n = 15) was left between the joint line and the implant during DIS. Specimens were mounted in a material-testing machine and load-to-failure was applied in a worst-case-scenario. Results Load to failure was 454 ± 111 N in the R-DIS1 group, 154 ± 71 N in the R-DIS2 group and 405 ± 105 N in the primary ACL-R group. Load-to-failure, stiffness and elongation of the group R-DIS2 were significantly inferior in comparison to R-DIS1 and ACL-R respectively (p < 0.001). No significant difference was found between load-to-failure, stiffness and elongation of R-DIS1 and the control group. Conclusion Primary stability of tibial aperture fixation in single-stage revision ACL-R in case of recurrent instability after DIS depends on monobloc position during ACL repair. Primary stability is comparable to aperture fixation in primary ACL-R, if a bone stock of 20 mm is left between the monobloc and the tibial joint line during the initial procedure.


Sign in / Sign up

Export Citation Format

Share Document