Explosion mitigation by metal grid with water curtain

Shock Waves ◽  
2021 ◽  
Author(s):  
T. Schunck ◽  
M. Bastide ◽  
D. Eckenfels ◽  
J. F. Legendre
2021 ◽  
Vol 11 (14) ◽  
pp. 6539
Author(s):  
Thérèse Schunck ◽  
Dominique Eckenfels

In this paper, protective barriers made of perforated plates with or without a water cover were investigated. In urban areas, such barriers could be envisaged for the protection of facades. An explosive-driven shock tube, combined with a retroreflective shadowgraph technique, was used to visualize the interaction of a blast wave profile with one or two plates made of expanded metal. Free-field air blast experiments were performed in order to evaluate the solution under real conditions. Configurations with either one or two grids were investigated. The transmitted pressure was measured on a wall placed behind the plate(s). It was observed that the overpressure and the impulse downstream of the plate(s) were reduced and that the mitigation performance increased with the number of plates. Adding a water layer on one grid contributed to enhance its mitigation capacity. In the setup with two plates, the addition of a water cover on the first grid induced only a modest improvement. This blast mitigation solution seems interesting for protection purposes.


2008 ◽  
Vol 18 (1) ◽  
pp. 1-36
Author(s):  
G. W. Zou ◽  
H. Dong ◽  
Y. Gao ◽  
W. K. Chow ◽  
M. Wu

2021 ◽  
Vol 129 (5) ◽  
pp. 053306
Author(s):  
E. J. Devid ◽  
M. Ronda-Lloret ◽  
D. Zhang ◽  
E. Schuler ◽  
D. Wang ◽  
...  
Keyword(s):  

AMB Express ◽  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Mohammad Malakootian ◽  
Ali Toolabi ◽  
Saeed Hosseini

AbstractBiological aerated filters (BAFs) have high filtration efficiency due to their tolerance of hydraulic and organic shocks are suitable for the treatment of complex and sanitary wastewater. In this study, for the first time, natural media of date kernel from Bam city was used as the BAF reactor media, with a meshing sand filter separated by a standard metal grid from the natural filter section used at the end of the reactor. This can be considered an innovation in the media and filtration. Aeration in the related reactor with 160 cm height was performed bilaterally as up-flow and continuously by nozzles throughout the reactor media. In this work, the actual effluent of the hospital wastewater treatment plant was employed as the inflow wastewater to the reactor, and its organic and inorganic parameters were measured before and after the treatment by the BAF reactor. The backwashing process was also studied in three ways: bottom backwashing (TB), top backwashing (BB), and top and bottom backwashing (TBBS), to determine the amount of water consumed and to achieve the desired result. According to the results obtained in this study, the removal efficiencies of inorganic and microbial contaminants, amoxicillin and azithromycin were obtained as follows: BOD5: 98.48%, COD: 92.42%, $${\text{NO}}_{3}^{ - }$$ NO 3 - : 99.4%, P: 93.3%, Coliforms: 97%, Color: 42.8%, Turbidity: 95%, Sulphate: 30%, TSS: 98.9%, Amoxicillin: 20% and azithromycin: 13%. In the backwashing process, the amount of water consumed in these three TB, BB, and TBBS methods were obtained 300, 164, and 118 L, respectively, So, TBBS method was selected as the optimal method. Based on the results obtained in this study, it is concluded that the BAF process with natural date kernel has a high efficiency in removing organic and inorganic contaminants from hospital wastewater, also the concentration of most of the effluent parameters was less or in accordance with EPA standard.


1982 ◽  
Vol 11 (1) ◽  
pp. 16-20 ◽  
Author(s):  
D. Pasternak ◽  
E. Rappeport

Low temperature energy sources for protected cropping include geothermal waters, waste heat from Industry, and trapped sunshine; application depends on the recovery of heat from circulating warmed water, either via the soil in which the plants are growing or via the air in the greenhouse. Soil warming pipes and ‘water-curtain’ systems of space-heating have shown promise, but heat storage, either for short periods or longer, remains a problem common to all such schemes.


Sign in / Sign up

Export Citation Format

Share Document