scholarly journals In silico evaluation of limited sampling strategies for individualized dosing of extended half-life factor IX concentrates in hemophilia B patients

Author(s):  
T. Preijers ◽  
M. W. F. van Spengler ◽  
K. Meijer ◽  
K. Fijnvandraat ◽  
K. Fischer ◽  
...  

Abstract Purpose Hemophilia B is a bleeding disorder, caused by a factor IX (FIX) deficiency. Recently, FIX concentrates with extended half-life (EHL) have become available. Prophylactic dosing of EHL-FIX concentrates can be optimized by assessment of individual pharmacokinetic (PK) parameters. To determine these parameters, limited sampling strategies (LSSs) may be applied. The study aims to establish adequate LSSs for estimating individual PK parameters of EHL-FIX concentrates using in silico evaluation. Methods Monte Carlo simulations were performed to obtain FIX activity versus time profiles using published population PK models for N9-GP (Refixia), rFIXFc (Alprolix), and rIX-FP (Idelvion). Fourteen LSSs, containing three or four samples taken within 8 days after administration, were formulated. Bayesian analysis was applied to obtain estimates for clearance (CL), half-life (t1/2), time to 1% (Time1%), and calculated weekly dose (Dose1%). Bias and precision of these estimates were assessed to determine which LSS was adequate. Results For all PK parameters of N9-GP, rFIXFc and rIX-FP bias was generally acceptable (range: −5% to 5%). For N9-GP, precision of all parameters for all LSSs was acceptable (< 25%). For rFIXFc, precision was acceptable for CL and Time1%, except for t1/2 (range: 27.1% to 44.7%) and Dose1% (range: 12% to 29.4%). For rIX-FP, all LSSs showed acceptable bias and precision, except for Dose1% using LSS with the last sample taken on day 3 (LSS 6 and 10). Conclusion Best performing LSSs were LSS with samples taken at days 1, 5, 7, and 8 (N9-GP and rFIXFc) and at days 1, 4, 6, and 8 (rIX-FP), respectively.

2018 ◽  
Vol 21 ◽  
pp. S111
Author(s):  
A Chhabra ◽  
D Spurden ◽  
BJ Tortella ◽  
PF Fogarty ◽  
A Pleil ◽  
...  

2017 ◽  
Vol 15 (9) ◽  
pp. 1737-1746 ◽  
Author(s):  
T. Preijers ◽  
H. C. A. M. Hazendonk ◽  
K. Fijnvandraat ◽  
F. W. G. Leebeek ◽  
M. H. Cnossen ◽  
...  

Haemophilia ◽  
2021 ◽  
Author(s):  
Alanna McEneny‐King ◽  
Pierre Chelle ◽  
Margaret H. Goggans ◽  
Patricia J. Barker ◽  
Timothy W. Jacobs ◽  
...  

Blood ◽  
2001 ◽  
Vol 97 (1) ◽  
pp. 130-138 ◽  
Author(s):  
Valder R. Arruda ◽  
James N. Hagstrom ◽  
Jeffrey Deitch ◽  
Terry Heiman-Patterson ◽  
Rodney M. Camire ◽  
...  

Abstract Recent data demonstrate that the introduction into skeletal muscle of an adeno-associated viral (AAV) vector expressing blood coagulation factor IX (F.IX) can result in long-term expression of the transgene product and amelioration of the bleeding diathesis in animals with hemophilia B. These data suggest that biologically active F.IX can be synthesized in skeletal muscle. Factor IX undergoes extensive posttranslational modifications in the liver, the normal site of synthesis. In addition to affecting specific activity, these posttranslational modifications can also affect recovery, half-life in the circulation, and the immunogenicity of the protein. Before initiating a human trial of an AAV-mediated, muscle-directed approach for treating hemophilia B, a detailed biochemical analysis of F.IX synthesized in skeletal muscle was carried out. As a model system, human myotubes transduced with an AAV vector expressing F.IX was used. F.IX was purified from conditioned medium using a novel strategy designed to purify material representative of all species of rF.IX in the medium. Purified F.IX was analyzed by sodium dodecyl sulfate–polyacrylamide gel electrophoresis (SDS-PAGE), N-terminal sequence analysis, chemical γ-carboxyglutamyl analysis, carbohydrate analysis, assays for tyrosine sulfation, and serine phosphorylation, and for specific activity. Results show that myotube-synthesized F.IX has specific activity similar to that of liver-synthesized F.IX. Posttranslational modifications critical for specific activity, including removal of the signal sequence and propeptide, and γ-carboxylation of the N-terminal glutamic acid residues, are also similar, but carbohydrate analysis and assessment of tyrosine sulfation and serine phosphorylation disclose differences. In vivo experiments in mice showed that these differences affect recovery but not half-life of muscle-synthesized F.IX.


2016 ◽  
Vol 42 (05) ◽  
pp. 518-525 ◽  
Author(s):  
Erik Berntorp ◽  
Nadine Andersson

There are two main bioengineering approaches to extending the half-life of factor (F)VIII or FIX products used for hemophilia replacement therapy. These are fusion to Fc-immunoglobulin G (FVIII and FIX) or to albumin (FIX) or pegylation/glycopegylation (FVIII and FIX). Four FVIII and three FIX products are in clinical development or have recently been licensed in regions of the world. The reported half-life extension is approximately 1.5-fold for FVIII and 2.5-fold, or even longer, for FIX. Clinical trials have shown promising results with respect to extension of dose intervals and efficacy in the treatment and prevention of bleeding events. The role of these products in clinical practice has been discussed in terms of either improving convenience and adherence through prolongation of the interval between infusions or maintaining current intervals thereby increasing trough levels and the safety margin against bleeds. This review of extended half-life products addresses the possibilities and problems of their introduction in hemophilia treatment.


2020 ◽  
Vol 40 (S 01) ◽  
pp. S15-S20
Author(s):  
Jens Müller ◽  
Georg Goldmann ◽  
Natascha Marquardt ◽  
Bernd Pötzsch ◽  
Johannes Oldenburg

AbstractDue to structural differences between extended half-life (EHL) factor VIII (FVIII) or FIX products and equivalent plasma wild-type molecules used for assay calibration, reagent-dependent discrepancies during monitoring of FVIII- and FIX-replacement therapies with EHL products have been described. To assess the performance of available one-stage clotting and chromogenic substrate assays on the Siemens Atellica COAG 360 analyzer, an in vitro study using spiked plasma samples was performed. The described results confirm previously described findings and allowed allocation of each EHL product to an appropriate assay. In addition, corresponding EHL product–specific analytes were defined within the order entry system of the University Hospital Bonn. The requirement of product-specific FVIII and FIX assays complicates patient monitoring and demonstrates the need for both continuous education and communication between treating physicians and the coagulation laboratory.


Blood ◽  
2010 ◽  
Vol 116 (21) ◽  
pp. 2197-2197 ◽  
Author(s):  
Chava Kimchi-Sarfaty ◽  
Vijaya L Simhadri ◽  
David Kopelman ◽  
Adam Friedman ◽  
Nathan Edwards ◽  
...  

Abstract Abstract 2197 Hemophilia B is characterized by structural and functional defects in coagulation factor IX (FIX) caused by mutations in the F9 gene. Various mutations (nonsense, missense, etc.) are known to be associated with the disease, including a synonymous V107V mutation reported recently by Knobe and colleagues (Knobe et al., Hemophilia, 2008). However the mechanism by which this synonymous mutation contributes to the disease has not yet been elucidated. Earlier we have shown that synonymous codon substitutions in the mRNA of the multidrug resistance protein (MDR1) may change the conformation of the protein and result in altered functionality (Kimchi-Sarfaty et al., Science, 2008). Here we have performed in silico analyses of the synonymous codon substitution (GTGàGTA) leading to the V107V polymorphism and found that it may change the mRNA structure, stability, codon usage, and 3D structure of the encoded protein. We hypothesize that changes in codon usage might affect the rhythm of protein translation and thus result in slightly altered FIX conformation. In vitro analyses of FIX mRNA and protein expression supported our in silico analyses. The GTGàGTA (V107V) synonymous mutation results in reduced expression levels as well as an encoded protein with a slightly different conformation compared to wild-type FIX. These results show that the V107V polymorphism is not silent and might cause mild hemophilia B. This work sheds further light on ways in which synonymous mutations impact disease. The findings and conclusions in this article have not been formally disseminated by the Food and Drug Administration and should not be construed to represent any Agency determination policy Disclosures: No relevant conflicts of interest to declare.


Blood ◽  
2013 ◽  
Vol 122 (21) ◽  
pp. 2333-2333
Author(s):  
Pamela R. Westmark ◽  
Pansakorn Tanratana ◽  
John P. Sheehan

Abstract Introduction Hemophilia B is an X-linked genetic disorder characterized by defective factor IX activity. Recombinant factor IX (rFIX) is employed as protein replacement for the treatment and prophylaxis of bleeding episodes. Antithrombin is the primary plasma inhibitor of activated factor IX (FIXa), and inhibition is enhanced by heparin/heparan sulfate. We hypothesize that selective disruption of protease interactions with heparin and antithrombin via mutations in the respective heparin- and antithrombin-binding exosites may enhance rFIX(a) efficacy by prolonging protease half-life in vivo. Aim To assess the effect of mutations in the FIX(a) heparin- and antithrombin-binding exosites on traditional coagulant activity, thrombin generation, and protease half-life in human plasma. Methods Human FIX cDNA constructs with alanine substitutions (chymotrypsinogen numbering) in the heparin exosite (K126A, K132A, K126A/K132A), antithrombin exosite (R150A), or both (K126A/R150A, K132A/R150A, K126A/K132A/R150A) were expressed in HEK293 cell lines. Recombinant zymogens were purified from conditioned media, and a portion activated to protease with human factor XIa. Zymogen and protease forms were characterized in APTT-based clotting assays, and tissue factor (TF) and FIXa-initiated thrombin generation (TG) assays in pooled human FIX-deficient plasma, respectively. Comparisons were made with human plasma-derived factor IX (pFIX) and recombinant FIX wild type (WT). Protease half-life in pooled, citrated human plasma was determined using a novel assay that detects FIXa activity by TG response. Results Zymogen coagulant activities (% WT ± S.E) were: pFIX 105.2 ± 2.8, WT 100 ± 7.1, K132A/R150A 75.8 ± 3.4, K126A 63.3 ± 2.3, R150A 62.4 ± 4.0, K132A 30.9 ± 1.0, K126A/R150A 27.0 ± 2.1, K126A/K132A 20.6 ± 9.2, and K126A/K132A/R150A 7.3 ± 3.8. Similarly, protease coagulant activities were: WT 100 ± 6.1, pFIXa 98.4 ± 11.4, K132A 91.4 ± 1.6, K132A/R150A 84.9 ± 2.8, R150A 77.1 ± 5.8, K126A 39.5 ± 2.4, K126A/R150A 25.3 ± 2.8, K126A/K132A/R150A 10.9 ± 0.6, and K126A/K132A 9.3 ± 0.6. In contrast to their relative coagulant activities, FIX K126A (1.9-fold), R150 (1.6-fold), and K132A/R150A (1.3-fold) supported increased peak thrombin concentrations during TF-triggered TG; pFIX, FIX K132A and K126A/R150A were similar to WT; and FIX K126A/K132A/R150A (0.6-fold) and K126A/K132A (0.2-fold) demonstrated marked reductions in peak thrombin relative to WT. In the FIXa-initiated TG assay, FIXa K126A/R150A and K132A/R150A (1.5-fold) demonstrated significantly increased peak thrombin concentrations; pFIXa, FIXa K132A, R150A, and K126A (0.8-1.0 fold) were similar to WT; while FIXa K126A/K132A and K126A/K132A/R150A demonstrated markedly reduced (0.2-0.3 fold) and delayed peak thrombin concentrations. In pooled, citrated FIX-deficient plasma, FIXa WT (40.9 ± 1.4 min) and K126A/K132A (37.2 ± 0.7 min) demonstrated similar half-lives, while FIXa R150A, K126A/R150A, and K132A/R150A all had half-lives > 2 hr. Conclusions Single exosite mutations resulted in mild to moderate reductions in coagulant activity, while the double mutation in the heparin exosite (K126A/K132A) markedly reduced activity, likely due to a synergistic effect on cofactor binding. Traditional coagulant activity did not accurately represent the ability of the mutant proteins to support thrombin generation. Despite variable reductions in coagulant activity, FIX K126A, K132A, R150A, K126A/R150A and K132A/R150A supported levels of plasma thrombin generation that were equal to or greater than FIX WT. The plasma half-life of FIXa WT activity was remarkably lengthy, and while mutations in the heparin exosite had negligible effects, R150A in the antithrombin exosite substantially increased protease half-life, consistent with a primary role for antithrombin in the plasma inhibition of FIXa. Thus, single exosite mutations did not significantly disrupt the procoagulant function of human FIX(a), and combined exosite mutations (K126A/R150A and K132A/R150A) maintain or enhance plasma thrombin generation while disrupting exosite-mediated regulatory mechanisms. The combination of intact procoagulant function with disruption of antithrombin- and heparin-mediated regulation of FIX(a) will potentially enhance in vivo recovery, prolong plasma half-life, and enhance the efficacy of hemophilia B replacement therapy. Disclosures: Sheehan: Novo Nordisk Access to Insight Basic Research Grant: Research Funding; Bayer Hemophilia Awards Program: Research Funding; Diagnostica Stago: reagents, reagents Other.


Blood ◽  
2012 ◽  
Vol 120 (12) ◽  
pp. 2405-2411 ◽  
Author(s):  
Elena Santagostino ◽  
Claude Negrier ◽  
Robert Klamroth ◽  
Andreas Tiede ◽  
Ingrid Pabinger-Fasching ◽  
...  

Abstract A recombinant fusion protein linking coagulation factor IX (FIX) with human albumin (rIX-FP) has been developed to facilitate hemophilia B treatment by less frequent FIX dosing. This first-in-human dose-escalation trial in 25 previously treated subjects with hemophilia B (FIX ≤ 2 IU/dL) examined the safety and pharmacokinetics of 25, 50, and 75 IU/kg rIX-FP. Patients in the 50-IU/kg cohort underwent a comparative pharmacokinetics assessment with their previous FIX product (plasma-derived or recombinant). No allergic reactions or inhibitors were observed. Four mild, possibly treatment-related adverse events were reported. In the 50-IU/kg cohort (13 subjects), the mean half-life of rIX-FP was 92 hours, more than 5 times longer than the subjects' previous FIX product. After 25 or 50 IU/kg rIX-FP administration, the baseline-corrected mean FIX activity remained elevated at day 7 (7.4 IU/dL and 13.4 IU/dL, respectively) and day 14 (2.5 IU/dL and 5.5 IU/dL, respectively). The incremental recovery of rIX-FP was higher than both recombinant and plasma-derived FIX (1.4 vs 0.95 and 1.1 IU/dL per IU/kg, respectively). These results demonstrated both the safety and improved pharmacokinetics of rIX-FP, thus indicating this new product with extended half-life as possibly able to control and prevent bleeding with less frequent injection. The trial was registered at www.clinicaltrials.gov as no. NCT01233440.


Blood ◽  
1992 ◽  
Vol 79 (3) ◽  
pp. 568-575 ◽  
Author(s):  
HC Kim ◽  
CW McMillan ◽  
GC White ◽  
GE Bergman ◽  
MW Horton ◽  
...  

Abstract Replacement therapy for hemophilia B (factor IX deficiency) using prothrombin complex concentrate (PCC) has been associated with serious complications of thromboembolic events and transmission of viral infections. Monoclonal antibody-purified factor IX (Mononine) provides a highly purified factor IX concentrate, while eliminating other vitamin K-dependent factors (II, VII, and X). Mononine was evaluated for in vivo recovery, half-life, and for its safety and efficacy in 10 patients with hemophilia B. The in vivo recovery of factor IX with Mononine was a 0.67 +/- 0.14 U/dL (mean +/- SD) increase per 1U/kg of infused factor IX, and the biologic half-life (t1/2), determined using the terminal phase of elimination, was 22.6 +/- 8.1 hours. Comparison of in vivo recovery of other vitamin K-dependent factors following a single infusion of either Mononine or PCC showed that, whereas Mononine infusion caused no changes in other vitamin K-dependent factors or in prothrombin activation fragment (F1+2), PCC infusion was associated with significant increases of factors II (2.7 U/dL per 1 U/dL of IX increase) and X (2.2 U/dL for 1 U/dL for 1 U/dL of IX). Patients who used Mononine as their sole therapeutic material during the 12-month period showed an excellent response in hemostasis for their bleeding episodes. Their experience with long-term use of Mononine was at least equivalent to their previous experience with PCC in the frequency and amount of factor usage. No patients developed antibody against mouse IgG or an increase in IX inhibitor during the 12-month period. These results indicate that monoclonal antibody-purified factor IX concentrate provides hemostatically effective factor IX replacement while avoiding extraneous thrombogenic substances.