Humeral lengthening and proximal deformity correction with monorail external fixator in young adults

2017 ◽  
Vol 42 (5) ◽  
pp. 1107-1111 ◽  
Author(s):  
Hongjiang Ruan ◽  
Yi Zhu ◽  
Shen Liu ◽  
Qinglin Kang
2019 ◽  
Vol 27 (3) ◽  
pp. 230949901987398 ◽  
Author(s):  
Aik Saw ◽  
Zi Hao Phang ◽  
Mohammed Khalid Alrasheed ◽  
Roshan Gunalan ◽  
Mohammed Ziyad Albaker ◽  
...  

Purpose: Management of Blount disease in adolescents and young adults is complex and associated with high risk of morbidities. Gradual correction with external fixator can minimize soft tissue injury and allow subsequent adjustment in degree of correction. This study investigates the surgical outcome and complication rate of gradual correction of neglected Blount disease through single-level extra-articular corticotomy. Methods: Patients treated for Blount disease using external fixator from 2002 to 2016 were recruited for the study. We used Ilizarov and Taylor Spatial Frame (TSF) external fixator to perform simultaneous correction of all the metaphyseal deformities without elevating the tibia plateau. Surgical outcome was evaluated using mechanical axis deviation (MAD), tibial femoral angle (TFA), and femoral condyle tibial shaft angle (FCTSA). Results: A total of 22 patients with 32 tibias have been recruited for the study. The mean MAD improved from 95 ± 51.4 mm to 9.0 ± 37.7 mm (medial to midpoint of the knee), mean TFA improved from 31 ± 15° varus to 2 ± 14° valgus, and mean FCTSA improved from 53 ± 14° to 86 ± 14°. Mean duration of frame application is 9.4 months. Two patients developed pathological fractures over the distracted bones, one developed delayed consolidation and other developed overcorrection. Conclusions: Correction of Blount disease can be achieved by gradual correction using Ilizarov or TSF external fixator with low risk of soft tissue complication. Longer duration of frame application should be considered to reduce the risk of pathological fracture or subsequent deformation of the corrected bone.


2019 ◽  
Vol 13 (2) ◽  
Author(s):  
Ying Ying Wu ◽  
Anton Plakseychuk ◽  
Kenji Shimada

Bone deformities are often complex three-dimensional (3D) deformities, and correcting them is difficult. To correct persistent clubfoot deformity in adolescents or adults, an external fixator is sometimes used to encourage tissue growth and preserve healthy tissues. However, it is difficult to set up, resulting in long surgeries and steep learning curves for surgeons. It is also bulky and obstructs patient mobility. In this paper, we introduce a new approach of defining clubfoot deformity correction as a six degrees-of-freedom (6DOF) correction, and then reducing it to just two degrees-of-freedom (2DOF) using the axis-angle representation. Therefore, only two physical trajectory joints are needed, which in turn enables a more compact fixator design. A computer planner was developed to minimize the bulk of the external fixator, and to optimize the distraction schedule to avoid overstretching the soft tissues. This reduces the learning curve for surgeons and shortens surgery time. To validate the system, a patient-specific clubfoot simulator was developed, and four experiments were performed on the clubfoot simulator. The accuracy of midfoot correction was 11 mm and 3.5 deg without loading, and 41 mm and 11.7 deg with loading. While the external fixator has to be more rigid to overcome resistance against correction, the surgical system itself was able to achieve accurate correction in less than 2 h. This is an improvement from the current method, which takes 2.5–4.5 h.


2013 ◽  
Vol 52 (3) ◽  
pp. 324-330 ◽  
Author(s):  
Munetomo Takata ◽  
Victor A. Vilensky ◽  
Hiroyuki Tsuchiya ◽  
Leonid N. Solomin

2006 ◽  
Vol 30 (6) ◽  
pp. 550-554 ◽  
Author(s):  
Hidenori Matsubara ◽  
Hiroyuki Tsuchiya ◽  
Keisuke Sakurakichi ◽  
Koji Watanabe ◽  
Katsuro Tomita

2011 ◽  
Vol 20 (2) ◽  
pp. 111-116 ◽  
Author(s):  
Alexander S. McLawhorn ◽  
Seth L. Sherman ◽  
Arkady Blyakher ◽  
Roger F. Widmann

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Yanshi Liu ◽  
Kai Liu ◽  
Feiyu Cai ◽  
Tao Zhang ◽  
Aihemaitijiang Yusufu

Abstract Background It is challenging to determine the orthogonality of radiographs in daily clinical practice. The purpose of this study was to show the usefulness of an additional foot ring which might determine the orthogonality of postoperative radiographs for the parameter measurement of hexapod external fixator. Methods We retrospectively analyzed 81 consecutive trauma patients with tibial shaft fractures treated by the hexapod external fixator at our institution from September 2014 to July 2019. Starting in March 2016, the postoperative radiographs for parameter measurement were obtained under the control of an additional foot ring. The final data consisted of 47 patients in traditional radiographs (Group I) and 34 patients under the control of foot ring during the radiographic process (Group II). The demographic data, original postoperative deformities, residual deformities after final correction, number of repeated radiographs after the first postoperative radiographs, time to the satisfactory reduction achieved, and external fixation time in all patients were documented and analyzed. The Johner–Wruhs criteria were used for the final clinical outcomes evaluation at the last clinical visit. Results Satisfactory reduction and bone union were achieved in all patients. There were no statistical significances between the two groups in the demographic data, original postoperative deformities, residual deformities after final correction, external fixation time, and the final clinical outcomes (P > 0.05). The mean number of repeated radiographs after the first radiographs (1.4 times) and mean time to the satisfactory reduction achieved (3.3 days) in patients with an additional foot ring used were all less than those without foot ring (2.4 times, 5.3 days) (P < 0.05). Conclusions The additional foot ring is a practical device to ensure the orthogonality of postoperative radiographs for the hexapod external fixator parameter measurement. Radiation exposure, duration of deformity correction, and cost for patients might be reduced due to the less repeated radiographs with the wrong position.


Sign in / Sign up

Export Citation Format

Share Document