Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study

2007 ◽  
Vol 17 (10) ◽  
pp. 2589-2597 ◽  
Author(s):  
Fabian Springer ◽  
Roland Schlierf ◽  
Joachim-Georg Pfeffer ◽  
Andreas H. Mahnken ◽  
Uwe Schnakenberg ◽  
...  
2010 ◽  
Vol 48 (7-8) ◽  
pp. 806-810 ◽  
Author(s):  
Xiaobo Yang ◽  
Nengli Dai ◽  
Hua Long ◽  
Peixiang Lu ◽  
Wan Li ◽  
...  

Perfusion ◽  
2019 ◽  
Vol 34 (7) ◽  
pp. 561-567
Author(s):  
Marco C Stehouwer ◽  
Roel de Vroege

Minimally invasive extracorporeal circulation systems are developed to decrease the deleterious effects of cardiopulmonary bypass. For instance, prime volume and foreign surface area are decreased in these systems. However, because of the lack of a venous reservoir in minimized systems, air handling properties of these minimally invasive extracorporeal circulation systems may be decreased as compared to conventional cardiopulmonary bypass systems. The aim of this in vitro study is to compare the air handling properties of two complete minimized cardiopulmonary bypass systems of two manufacturers, of which one system is provided with the air purge control. In an in vitro study, two minimally invasive extracorporeal circulation systems, Inspire Min.I manufactured by Sorin Group Italia, Mirandola, Italy (LivaNova, London, United Kingdom) and minimized extracorporeal circulation manufactured by Maquet, Rastatt, Germany (Getinge, Germany), were challenged with two types of air challenges; a bolus air challenge and a gaseous microemboli challenge. The air removal characteristics of the venous bubble traps and of the complete minimally invasive extracorporeal circulation systems were assessed by measuring the gaseous microemboli volume and number downstream of the venous bubble traps in the arterial line with a bubble counter. No significant differences were observed in air reduction between the venous bubble traps of Getinge (venous bubble traps) and LivaNova (Inspire venous bubble traps 8 in conjunction with the air purge control). Similarly, no significant differences were observed in volume and number of gaseous microemboli in the arterial line of both complete minimally invasive extracorporeal circulation systems. However, the gaseous microemboli load of the Inspire Min.I system was marginally lower after both the bolus air and the gaseous microemboli challenges. Both minimally invasive extracorporeal circulation systems assessed in this study, the LivaNova Inspire Min.I and the Getinge minimized extracorporeal circulation, showed comparable air removal properties, after both bolus and gaseous microemboli air challenges. Besides, air purge control automatic air removal system provided with the LivaNova Inspire Min.I. system may enhance patient’s safety with the use of a minimally invasive extracorporeal circulation system. We consider both systems equally safe for clinical use.


Materials ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2580
Author(s):  
Marco Jäggi ◽  
Eva Magni ◽  
Florin Eggmann ◽  
Ashraf ElAyouti ◽  
Thomas Connert ◽  
...  

This in vitro study aimed to evaluate apical pressure during irrigant delivery with syringe irrigation in immature teeth with an open apical foramen. Conventional syringe irrigation was performed in a 3D-printed immature incisor. A 5 mL syringe combined with 25 G and 30 G cannulas was used. Open-ended and side-vented needle tip designs were assessed. Cannulas were placed at tooth length (TL), TL −1 mm, TL −2 mm, and TL −4 mm. The syringe plunger was moved with a force of 10 N, 20 N, 40 N, and 80 N to simulate clinical conditions. A pressure sensor measured periapical pressures during irrigation. Each experiment was repeated 10 times. Data were analyzed descriptively (maximum, mean, standard deviation, 95% CI) with the critical threshold indicative of extrusion set at 7.64 mbar. 30 G cannulas with both needle tip designs never exceeded the threshold at any TL with a plunger force of 10–40 N. At 80 N, 30 G open-ended cannulas exceeded the threshold in 10%, 30 G side-vented in 20–60% of the measurements. At any TL, 25 G open-ended cannulas and 25 G side-vented cannulas never crossed the threshold with forces of 10–20 N and 10 N, respectively. Consequently, 30 G cannulas with both designs can be recommended for irrigant delivery in immature teeth. 25 G cannulas ought to be used with caution.


Sign in / Sign up

Export Citation Format

Share Document