Diffusion-weighted imaging with acquisition of three b-values for response evaluation of neuroendocrine liver metastases undergoing selective internal radiotherapy

2013 ◽  
Vol 24 (2) ◽  
pp. 267-276 ◽  
Author(s):  
Guido M. Kukuk ◽  
Petra Mürtz ◽  
Frank Träber ◽  
Carsten Meyer ◽  
Jan Ullrich ◽  
...  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jianxing Qiu ◽  
Jing Liu ◽  
Zhongxu Bi ◽  
Xiaowei Sun ◽  
Xin Wang ◽  
...  

Abstract Purpose To compare integrated slice-specific dynamic shimming (iShim) diffusion weighted imaging (DWI) and single-shot echo-planar imaging (SS-EPI) DWI in image quality and pathological characterization of rectal cancer. Materials and methods A total of 193 consecutive rectal tumor patients were enrolled for retrospective analysis. Among them, 101 patients underwent iShim-DWI (b = 0, 800, and 1600 s/mm2) and 92 patients underwent SS-EPI-DWI (b = 0, and 1000 s/mm2). Qualitative analyses of both DWI techniques was performed by two independent readers; including adequate fat suppression, the presence of artifacts and image quality. Quantitative analysis was performed by calculating standard deviation (SD) of the gluteus maximus, signal intensity (SI) of lesion and residual normal rectal wall, apparent diffusion coefficient (ADC) values (generated by b values of 0, 800 and 1600 s/mm2 for iShim-DWI, and by b values of 0 and 1000 s/mm2 for SS-EPI-DWI) and image quality parameters, such as signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of primary rectal tumor. For the primary rectal cancer, two pathological groups were divided according to pathological results: Group 1 (well-differentiated) and Group 2 (poorly differentiated). Statistical analyses were performed with p < 0.05 as significant difference. Results Compared with SS-EPI-DWI, significantly higher scores of image quality were obtained in iShim-DWI cases (P < 0.001). The SDbackground was significantly reduced on b = 1600 s/mm2 images and ADC maps of iShim-DWI. Both SNR and CNR of b = 800 s/mm2 and b = 1600 s/mm2 images in iShim-DWI were higher than those of b = 1000 s/mm2 images in SS-EPI-DWI. In primary rectal cancer of iShim-DWI cohort, SIlesion was significantly higher than SIrectum in both b = 800 and 1600 s/mm2 images. ADC values were significantly lower in Group 2 (0.732 ± 0.08) × 10− 3 mm2/s) than those in Group 1 ((0.912 ± 0.21) × 10− 3 mm2/s). ROC analyses showed significance of ADC values and SIlesion between the two groups. Conclusion iShim-DWI with b values of 0, 800 and 1600 s/mm2 is a promising technique of high image quality in rectal tumor imaging, and has potential ability to differentiate rectal cancer from normal wall and predicting pathological characterization.


PLoS ONE ◽  
2021 ◽  
Vol 16 (2) ◽  
pp. e0247301
Author(s):  
Jelena Djokić Kovač ◽  
Marko Daković ◽  
Aleksandra Janković ◽  
Milica Mitrović ◽  
Vladimir Dugalić ◽  
...  

Background The utility of intravoxel incoherent motion (IVIM) related parameters in differentiation of hypovascular liver lesions is still unknown. Purpose The purpose of this study was to evaluate the value of IVIM related parameters in comparison to apparent diffusion coefficient (ADC) for differentiation among intrahepatic mass-forming cholangiocarcinoma (IMC), and hypovascular liver metastases (HLM). Methods Seventy-four prospectively enrolled patients (21 IMC, and 53 HLM) underwent 1.5T magnetic resonance examination with IVIM diffusion-weighted imaging using seven b values (0–800 s/mm2). Two independent readers performed quantitative analysis of IVIM-related parameters and ADC. Interobserver reliability was tested using a intraclass correlation coefficient. ADC, true diffusion coefficient (D), perfusion-related diffusion coefficient (D*), and perfusion fraction (ƒ) were compared among the lesions using Kruskal-Wallis H test. The diagnostic accuracy of each parameter was assessed by receiver operating characteristic (ROC) curve analysis. Results The interobserver agreement was good for ADC (0.802), and excellent for D, D*, and ƒ (0.911, 0.927, and 0.942, respectively). ADC, and D values were significantly different among IMC and HLM (both p < 0.05), while there was no significant difference among these lesions for ƒ and D* (p = 0.101, and p = 0.612, respectively). ROC analysis showed higher diagnostic performance of D in comparison to ADC (AUC = 0.879 vs 0.821). Conclusion IVIM-derived parameters in particular D, in addition to ADC, could help in differentiation between most common hypovascular malignant liver lesions, intrahepatic mass—forming cholangiocarcinoma and hypovascular liver metastases.


BMC Cancer ◽  
2012 ◽  
Vol 12 (1) ◽  
Author(s):  
Xin Chen ◽  
Xi-Jing He ◽  
Rui Jin ◽  
You-Min Guo ◽  
Xian Zhao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document