scholarly journals One view or two views for wide-angle tomosynthesis with synthetic mammography in the assessment setting?

Author(s):  
Paola Clauser ◽  
Pascal A. T. Baltzer ◽  
Panagiotis Kapetas ◽  
Ramona Woitek ◽  
Michael Weber ◽  
...  

Abstract Objectives To evaluate the diagnostic performance in the assessment setting of three protocols: one-view wide-angle digital breast tomosynthesis (WA-DBT) with synthetic mammography (SM), two-view WA-DBT/SM, and two-view digital mammography (DM). Methods Included in this retrospective study were patients who underwent bilateral two-view DM and WA-DBT. SM were reconstructed from the WA-DBT data. The standard of reference was histology and/or 2 years follow-up. Included were 205 women with 179 lesions (89 malignant, 90 benign). Four blinded readers randomly evaluated images to assess density, lesion type, and level of suspicion according to BI-RADS. Three protocols were evaluated: two-view DM, one-view (mediolateral oblique) WA-DBT/SM, and two-view WA-DBT/SM. Detection rate, sensitivity, specificity, and accuracy were calculated and compared using multivariate analysis. Reading time was assessed. Results The detection rate was higher with two-view WA-DBT/SM (p = 0.063). Sensitivity was higher for two-view WA-DBT/SM compared to two-view DM (p = 0.001) and one-view WA-DBT/SM (p = 0.058). No significant differences in specificity were found. Accuracy was higher with both one-view WA-DBT/SM and two-view WA-DBT/SM compared to DM (p = 0.003 and > 0.001, respectively). Accuracy did not differ between one- and two-view WA-DBT/SM. Two-view WA-DBT/SM performed better for masses and asymmetries. Reading times were significantly longer when WA-DBT was evaluated. Conclusions One-view and two-view WA-DBT/SM can achieve a higher diagnostic performance compared to two-view DM. The detection rate and sensitivity were highest with two-view WA-DBT/SM. Two-view WA-DBT/SM appears to be the most appropriate tool for the assessment of breast lesions. Key Points • Detection rate with two-view wide-angle digital breast tomosynthesis (WA-DBT) is significantly higher than with two-view digital mammography in the assessment setting. • Diagnostic accuracy of one-view and two-view WA-DBT with synthetic mammography (SM) in the assessment setting is higher than that of two-view digital mammography. • Compared to one-view WA-DBT with SM, two-view WA-DBT with SM seems to be the most appropriate tool for the assessment of breast lesions.

2019 ◽  
Vol 54 (2) ◽  
pp. 83-88 ◽  
Author(s):  
Paola Clauser ◽  
Pascal A.T. Baltzer ◽  
Panagiotis Kapetas ◽  
Ramona Woitek ◽  
Michael Weber ◽  
...  

Breast Care ◽  
2017 ◽  
Vol 12 (2) ◽  
pp. 91-96 ◽  
Author(s):  
Sylvia Heywang-Köbrunner ◽  
Alexander Jaensch ◽  
Astrid Hacker ◽  
Sabina Wulz-Horber ◽  
Thomas Mertelmeier ◽  
...  

Background: The purpose of this study was to countercheck the equivalence of single-view digital breast tomosynthesis (DBT) or DBT with additional views (DBT+AV) compared to traditional standard assessment by additional views (AV) in patients with a screen-detected abnormality. Patients and Methods: Patients with a screen-detected abnormality were consecutively invited to obtain 1 single-view wide-angle DBT in addition to the indicated AV. The study was approved by the local ethics committee and by the Federal Office for Radiation Protection. Results: This study is based on 311 lesions in 285 patients with a follow-up of > 2 years and/or biopsy. Counting BI-RADS 0 and 3 as positive calls, the sensitivity/specificity of DBT+AV versus DBT only versus AV only were 96.4/54.3%, 96.4/56.6%, and 90.9/42.2%, respectively. The specificities and BI-RADS classifications differed significantly (p < 0.01). AV appeared unnecessary in 88.8% of the cases. Conclusion: DBT appeared to be at least equivalent to AV for assessing indeterminate screen-detected lesions and could replace AV for most lesions. To obtain the extra information appears possible without increasing the overall radiation dose. Subsequent blinded reader studies are ongoing.


Author(s):  
Rana M. Naeim ◽  
Rania A. Marouf ◽  
Merhan A. Nasr ◽  
Marwa E. Abd El-Rahman

Abstract Background Mammography has been the mainstay for the detection of breast cancer over decades. It has gradually advanced from screen film to full-field digital mammography. Tomosynthesis has evolved as advanced imaging for early diagnosis of breast lesions with a promising role in both diagnostic and screening settings, particularly in dense and treated breasts. Results This study included 90 female patients according to our inclusion criteria. All patients perform full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) and were classified according to breast density and age groups. Breast imaging reporting and data system (BI-RADS) scoring was assigned for each case. This was correlated with the final diagnosis; the diagnostic indices of mammography were a sensitivity of 64.44%, a specificity of 77.78%, a positive predictive value (PPV) 74.63%, a negative predictive value (NPV) of 68.63%, and a diagnostic accuracy of 71.11%. Diagnostic indices of DBT were a sensitivity of 100%, a specificity of 97.77%, PPV 97.78%, NPV 100%, and diagnostic accuracy of 97.7%. In patients with dense breasts American College of Radiology (ACR) (c and d), 61% of cases had changed their BIRADS scoring with the addition of tomosynthesis. Yet, in non-dense breast ACR (a and b), 45% of cases had changed BIRADS scoring with the addition of DBT to FFDM. Conclusion DBT is a promising imaging modality offering better detection and characterization of different breast abnormalities, especially in young females, and those with dense breasts with an increase of sensitivity and specificity than FFDM. This leads to a reduction in the recalled cases, negative biopsies, and assessing the efficacy of therapy as it enables improving detection of breast cancer and different breast lesions not visualized by conventional mammography


2018 ◽  
Vol 28 (1) ◽  
pp. 10-15 ◽  
Author(s):  
Akram M. Asbeutah ◽  
Nouralhuda Karmani ◽  
AbdulAziz A. Asbeutah ◽  
Yasmin A. Echreshzadeh ◽  
Abdullah A. AlMajran ◽  
...  

Objective: To investigate the sensitivity and specificity of digital mammography (DM) and digital breast tomosynthesis (DBT) for the detection of breast cancer in comparison to histopathology findings. Subjects and Methods: We included 65 breast lesions in 58 women, each detected by two diagnostic mammography techniques – DM and DBT using Senographe Essential (GE Healthcare, Buc, France) – and subsequently confirmed by histopathology. The Breast Imaging Reporting and Data System was used for characterizing the lesions. Results: The average age of women was 48.3 years (range 26–81 years). There were 34 malignant and 31 benign breast lesions. The sensitivity of DM and DBT was 73.5 and 100%, respectively, while the specificity was 67.7 and 94%, respectively. Receiver operating characteristic curve analysis showed an overall diagnostic advantage of DBT over DM, with a significant difference between DBT and DM (p < 0.001). By performing Cohen’s kappa test, we found that there was a strong level of agreement according to Altman guidelines between DBT and histopathology findings (0.97), but a weak agreement between DM and histopathology findings (0.47). Conclusion: DBT improves the clinical accuracy of mammography by increasing both sensitivity and specificity. We believe that this improvement is due to improved image visibility and quality. These results could be of interest to health care institutions as they may impact their decision on whether to upgrade to DBT not only for diagnosis, but also for screening.