scholarly journals Use of diffuse reflections in tunable diode laser absorption spectroscopy: implications of laser speckle for gas absorption measurements

2008 ◽  
Vol 90 (2) ◽  
pp. 279-288 ◽  
Author(s):  
D. Masiyano ◽  
J. Hodgkinson ◽  
R.P. Tatam
2021 ◽  
Vol 16 (2) ◽  
pp. 222-229
Author(s):  
Lin Feng ◽  
Jian Wang ◽  
Chao Ding

Tunable diode laser absorption spectroscopy (TDLAS) technology is adopted herein to detect fire gas produced in the early stage of the fire. Based on this technology, a fire warning detection system with multiple lasers and detectors is proposed. Multiple drivers input laser’s temperature and injected current data, making its output wavelength consistent with the measured gas’ absorption peak wavelengths in absorption spectroscopy. Multiple light beams are coupled to the same optical fiber. After the light beams pass through the long optical path absorption cell filled with fire gas, the beams are separated by a converter. The signals are demodulated by different detectors and further analyzed for fire warnings. After the fire warning system’s design, the system’s various hardware modules are designed, including the light source module, TDLAS controller, gas chamber module, photoelectric detector, and data collection. When the temperature remains unchanged, the output wavelength is linearly related to the injected current. When the injected current remains unchanged, the output wavelength is linearly related to the operating temperature. With a semiconductor laser’s injected current of 40 mA, the initial temperature of 38.6 °C, and the output wavelength of 1578.16 nm, the output wavelength increases continuously as the temperature increases. The harmonic signal amplitude after gas absorption is positively correlated with the measured gas concentration, indicating that the second harmonic signals can estimate the fire gas concentration.


2014 ◽  
Vol 986-987 ◽  
pp. 1523-1526
Author(s):  
Hui Jie Zheng ◽  
Wei Quan

An experimental technique was designed to measure the gas number density distribution of alkali vapor by tunable diode laser absorption spectroscopy. The measurement method was developed by scanning multiple gas absorption lines and fitting the experiment data with Lorentz profile to obtain the density. A discretization strategy of the equation for absorption lines is also present here as well as a constrained liner least-square fitting method. A simulation model was set up to reconstruct the two-dimensional distribution of number density and the feasibility of the reconstruction was verified. In the end, this work demonstrates the calculation error of the acquired number density and the distribution. The results indicated that the error would be no more than 5% if the measurement error is less than 9%.


2013 ◽  
Vol 38 (14) ◽  
pp. 2428 ◽  
Author(s):  
P. Adámek ◽  
J. Olejníček ◽  
M. Čada ◽  
Š. Kment ◽  
Z. Hubička