scholarly journals Customised, individually made total knee arthroplasty shows promising 1-year clinical and patient reported outcomes

Author(s):  
Céline S. Moret ◽  
Michael T. Hirschmann ◽  
Nicole Vogel ◽  
Markus P. Arnold

Abstract Introduction Customised individually made (CIM) implants for total knee arthroplasty (TKA) were introduced about 10 years ago. These implants aim to reduce the risk of prosthesis-related issues resulting from anthropometric differences between different knees. The purpose of this study was to analyse the short-term clinical outcome and patient reported outcome measures (PROMs) of a specific CIM implant, the ORIGIN® knee replacement system (Symbios, Yverdon-les-Bains, Switzerland), which was introduced in 2018. Materials and methods This is a prospective cohort study of patients undergoing primary posterior-stabilised (PS) CIM TKA using the specific ORIGIN® knee replacement system, (Symbios, Yverdon-les-Bains, Switzerland). TKAs were performed from February 2019 to October 2020. Data was collected preoperatively and postoperatively at 4 and 12 months. Outcome measures included the objective part of the Knee Society Score (KSS) with the range of motion (ROM) and the following PROMs: the Knee injury and Osteoarthritis Outcome Score (KOOS), the Forgotten Joint Score (FJS-12), the EuroQol, five dimensions, three levels (EQ-5D-3L) with the EuroQol visual analogue scale (EQ-VAS) and patient satisfaction. Differences in pre- to preoperative data were assessed with paired sample t tests. A p value < 0.05 was considered significant. Results Twenty-five CIM TKA (20 patients, 8 female) were included. The mean age at surgery was 66 years (SD, 6.9). At 4 and 12 months, significant improvements in the KSS (p < 0.001), the ROM (p < 0.001), all KOOS subscales (p < 0.001), the FJS (p < 0.001) and the EQ-5D-3L (p < 0.026) were found. Satisfaction rate was 91% and 88% at 4 and 12 months, respectively. Intraoperative complications did not occur and no revision surgeries were undertaken. Conclusions The present study demonstrated significant improvements in the KSS and specific PROMs 1 year after CIM TKA. This study suggests that CIM TKA is a safe and suitable option, which can yield good clinical outcome and PROMs at least during short-term follow-up.

2019 ◽  
Vol 7 (6_suppl4) ◽  
pp. 2325967119S0023
Author(s):  
Johannes Holz ◽  
Stefan Schneider ◽  
Ansgar Ilg ◽  
Rene Kaiser

Aims and Objectives: The purpose was to evaluate the clinical outcomes of patients with knee osteoarthritis treated with bicompartmental arthroplasty (BKA) in comparison to unicompartmental (UKA), patellofemoral (PFA) and total knee arthroplasty (TKA) in a single center. Materials and Methods: This is a prospective study analyzing a consecutive series of 396 patients from two surgeons in a single center. In 191 men and 205 women either partial or total knee replacement were performed. Their mean age at surgery was 63±6,85 years and mean BMI 29,55±5,00 kg/m2. In 238 patients UKA, in 125 TKA, in 21 PFA and in 11 patients BKA was performed. Implants were cemented and made of cobalt chrome in partial knee and zirconium oxide in total knee replacement. Demographics and patient reported outcomes (VAS, KOOS, Oxford Knee Score (OKS)) were collected preoperatively and 3,6 and 12 months postoperatively. A total of 202 patients have thus far completed the 12 months follow-up time point. Results: All mean KOOS and OKS scores improved significantly 1 year after surgery (p<0.05). Mean preoperative aggregated KOOS improved from 49,0±14,1 to 74,3±17,8 in UKA, from 44,1±12,9 to 67,5±9,4 in PFA, from 46,1±15,1 to 71,0±14,8 in TKA and from 45,7±13,8 to 72,6±9,7 in BKA (p<0.05). Mean preoperative aggregated OKS improved from 25,1±7,6) to 38,5±9,7 in UKA, from 23,0±7,6 to 36,8±3,8 in PFA, from 23,4±8,2 to 37,3±8,1 in TKA and from 22,9±9,6 to 37,0±1,5 in BKA (p<0.05). The mean pain level (VAS)decreased from pre-treatment to 12 months after surgery in UKA from 5,5 to 1,6, in PFA from 6,1 to 2,5, in TKA from 6,0 to 1,9 and in BKA from 6,6 to 2,6. One patient (0.4%) underwent revision (at 3 month for inlay dislocation). Conclusion: This study shows excellent early clinical results of patients treated with unicompartmental, bicompartmental and total knee arthroplasty. Adherence to strict indications lead to a significant improvement of patient reported outcomes and a low revision rate one year postoperatively. The reported results for BKA are comparable to those of patients treated with unicompartmental arthroplasty. We conclude that bicompartmental arthroplasty is a safe and reliable surgery for patients with bicompartmental osteoarthritis.


2017 ◽  
Vol 31 (08) ◽  
pp. 754-760 ◽  
Author(s):  
Ryan Degen ◽  
Jacob Matz ◽  
Matthew Teeter ◽  
Brent Lanting ◽  
James Howard ◽  
...  

AbstractTotal knee arthroplasty (TKA) is an effective, durable treatment for knee osteoarthritis. However, a subset of patients experiences incomplete pain relief and ongoing dysfunction. Posterior condylar offset (PCO) has previously been shown to be associated with postoperative range of motion (ROM) following TKA; however, an association with patient-reported outcome measures (PROMs) has not been established. The purpose of this study was to evaluate the association between PCO and postoperative ROM and PROMs. A retrospective review of 970 posterior-stabilized single design TKAs was performed. Preoperative and postoperative radiographs were analyzed to measure the change in PCO and anteroposterior (AP) femoral dimension. Clinical outcome measures, including Short Form-12 physical and mental component summaries, Western Ontario and McMaster Universities Arthritis Index, and Knee Society Score were reviewed to determine if these were influenced by changes in PCO and AP dimension. PCO was increased by more than 3 mm in 15.1%, maintained (within 3 mm) in 59.6%, and decreased by more than 3 mm in 25.3% of patients. Comparing between these groups, there were no significant differences in postoperative ROM or PROM. AP dimension increased in 24.4%, maintained in 47.8%, and decreased in 27.8%. Similarly, there were no significant differences in ROM or PROM between these groups. Spearman's correlation analyses failed to identify an association between PCO and ROM or PROMs. In conclusion, increasing or decreasing PCO or AP femoral dimension with this PS TKA design did not significantly affect postoperative ROM or PROM. Similarly, maintenance of PCO within one implant size with this system compared with optimal sizing had no deleterious effect on TKA outcomes.


Sign in / Sign up

Export Citation Format

Share Document