patient reported outcome measures
Recently Published Documents


TOTAL DOCUMENTS

2392
(FIVE YEARS 1331)

H-INDEX

62
(FIVE YEARS 11)

Diagnostics ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 199
Author(s):  
Marta Mirando ◽  
Corrado Conti ◽  
Federica Zeni ◽  
Fabio Pedicini ◽  
Antonio Nardone ◽  
...  

(1) Background: Ankle fracture results in pain, swelling, stiffness and strength reduction, leading to an altered biomechanical behavior of the joint during the gait cycle. Nevertheless, a common pattern of kinematic alterations has still not been defined. To this end, we analyzed the literature on instrumental gait assessment after ankle fracture, and its correlation with evaluator-based and patient-reported outcome measures. (2) Methods: We conducted a systematic search, according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines, of articles published from January 2000 to June 2021 in PubMed, Embase and PEDro on instrumental gait assessment after ankle fracture. (3) Results: Several changes in gait occur after ankle fracture, including a reduction in step length, swing time, single support time, stride length, cadence, speed and an earlier foot-off time in the affected side. Additionally, trunk movement symmetry (especially vertical) is significantly reduced after ankle fracture. The instrumental assessments correlate with different clinical outcome measures. (4) Conclusions: Instrumental gait assessment can provide an objective characterization of the gait alterations after ankle fracture. Such assessment is important not only in clinical practice to assess patients’ performance but also in clinical research as a reference point to evaluate existing or new rehabilitative interventions.


Author(s):  
Benson S. Chen ◽  
Tomasz Galus ◽  
Stephanie Archer ◽  
Valerija Tadić ◽  
Mike Horton ◽  
...  

Abstract Purpose To identify and comprehensively evaluate studies capturing the experience of individuals affected by an inherited optic neuropathy (ION), focusing on patient-reported outcome measures (PROMs) and qualitative studies where the health status and quality of life (QoL) of these individuals have been explored. Methods Systematic review of five databases using a search strategy combining four concepts: (1) ION; (2) QoL and health status; (3) PROMs; and (4) qualitative research. Studies assessing the impact of ION on any QoL domain using a PROM or qualitative methodology were included and appraised, using criteria based on the COSMIN checklist (for PROM studies) and the CASP checklist (for qualitative studies). Results Of 1326 unique articles identified, six studies were included. Five PROMs were identified: Visual Function Index (VF-14); Hospital Anxiety and Depression Scale (HADS); a novel graphical online assessment tool (NGOAT) for reporting emotional response to vision loss; a new PROM informed by the DSM-V Criteria for Major Depressive Disorder; and an interpersonal and career ‘impact rating’ PROM. The psychometric performance of included PROMs were poorly described. Qualitative studies found that vision loss resulted in psychosocial losses including loss of social and communication skills and loss of independence and freedom. Factors that modified the response to vision loss were also identified. Conclusion The current PROMs used by individuals with ION have poor content coverage, primarily measuring activity limitation and emotional well-being, and insufficient reporting of psychometric performance. There is a need to develop a PROM for individuals ION to report their experiences of living with their condition.


Life ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 110
Author(s):  
Matthias Holzbauer ◽  
Gerhard Großbötzl ◽  
Stefan Mathias Froschauer

Pollux adductus deformity is an accompanying symptom of thumb carpometacarpal osteoarthritis. We describe a case of a patient who presented with increased muscle tone of the adductor pollicis muscle and chronic pain in the thenar musculature, i.e., recurrence of an adduction deformity. The patient reported a symptom-free period of 5.5 years after having received resection-suspension-arthroplasty for stage IV thumb carpometacarpal osteoarthritis until spasmodic pain appeared. Due to the functional impairment of this condition, we administered therapy including 100 units of Botox® (onabotulinumtoxinA, Allergan, Dublin, Ireland) injected with a fanning technique into the adductor pollicis muscle. Thus, we observed a substantial improvement in the patient-reported outcome measures as well as pain levels compared with initial values. The current case shows the pivotal role of the adductor pollicis muscle when patients report pain at the base of the thumb, which can cause considerable impairments despite the complication-free surgical treatment of thumb CMC OA.


Author(s):  
Bernardo Sousa-Pinto ◽  
João Fonseca ◽  
Bilun Gemicioglu ◽  
Frederico Regateiro ◽  
Nicola Scichilone ◽  
...  

Author(s):  
Matthew Scott-Young ◽  
Evelyne Rathbone ◽  
Lauren Grierson

Abstract Background According to published meta-analyses, cervical total disc replacement (CTDR) seems to be superior to anterior cervical decompression and fusion (ACDF) in most clinical parameters. Despite short-term clinical success of CTDR, there are concerns regarding long-term durability of these prostheses. Methods This prospective study involved 382 patients who received standalone CTDR or a hybrid procedure (ACDF/CTDR). A retrospective comparison between different CTDR devices was conducted regarding patient-reported outcome measures (PROMs), failure scenarios, and revision surgeries. The M6-C™ Artificial Cervical Disc (Orthofix, Lewisville, Texas) cohort was compared to the other CTDR devices clinically. Etiological reasons for revision, and the surgical technique of the revision was investigated. Results Fifty-three patients received M6-C CTDR. Eighteen patients (34%) were revised at an average of 67 months postoperatively for wear-induced osteolysis. There were three additional cases of pending revision. The PROMs of the two groups were similar, indicating that the failure mode (wear-induced osteolysis) is often asymptomatic. The demographics of the two groups were also similar, with more women undergoing revision surgery than men. There were three one-level CTDR, four two-level hybrids, seven three-level hybrids, and three four-level hybrids revised anteriorly. Sixteen patients underwent removal of the prosthesis and were treated according to the extent of osteolysis. There were four vertebrectomies, six revisions to ACDF, and six revisions to another CTDR. One patient underwent supplemental fixation using a posterior approach. The other CTDR cohort had an incidence of 3.3% at the equivalent time, and none of these were due to osteolysis or wear-related events. Conclusions There is a concerning midterm failure rate related to ultra-high-molecular-weight-polyethylene wear-induced osteolysis in the M6-C. Patients implanted with the M6-C prosthesis should be contacted, informed, and clinically and radiologically assessed.


BJUI Compass ◽  
2022 ◽  
Author(s):  
Alexander Ng ◽  
Pramit Khetrapal ◽  
Chris Brew‐Graves ◽  
Nicola Muirhead ◽  
Aqua Asif ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document