scholarly journals Forty years after the first totally implantable venous access device (TIVAD) implant: the pure surgical cut-down technique only avoids immediate complications that can be fatal

Author(s):  
Adriana Toro ◽  
Elena Schembari ◽  
Emanuele Gaspare Fontana ◽  
Salomone Di Saverio ◽  
Isidoro Di Carlo

Abstract Aim Even though TIVADs have been implanted for a long time, immediate complications are still occurring. The aim of this work was to review different techniques of placing TIVAD implants to evaluate the aetiology of immediate complications. Methods A systematic literature review was performed using the PubMed, Cochrane and Google Scholar databases in accordance with the PRISMA guidelines. The patient numbers, number of implanted devices, specialists involved, implant techniques, implant sites and immediate complication onsets were studied. Results Of the 1256 manuscripts reviewed, 36 were eligible for inclusion in the study, for a total of 17,388 patients with equivalent TIVAD implantation. A total of 2745 patients (15.8%) were treated with a surgical technique and 14,643 patients (84.2%) were treated with a percutaneous technique. Of the 2745 devices (15.8%) implanted by a surgical technique, 1721 devices (62.7%) were placed in the cephalic vein (CFV). Of the 14,643 implants (84.2%) placed with a percutaneous technique, 5784 devices (39.5%) were placed in the internal jugular vein (IJV), and 5321 devices (36.3%) were placed in the subclavian vein (SCV). The number of immediate complications in patients undergoing surgical techniques was 32 (1.2%) HMMs. In patients treated with a percutaneous technique, the number of total complications were 333 (2.8%): 71 PNX (0.5%), 2 HMT (0.01%), 175 accidental artery punctures AAP (1.2%) and 85 HMM (0.6%). No mortality was reported with either technique. Conclusion The percutaneous approach is currently the most commonly used technique to implant a TIVAD, but despite specialist’s best efforts, immediate complications are still occurring. Surgical cut-down, 40 years after the first implant, is still the only technique that can avoid all of the immediate complications that can be fatal.

2019 ◽  
Vol 20 (5) ◽  
pp. 563-566 ◽  
Author(s):  
Fumito Saijo ◽  
Mitsuhisa Mutoh ◽  
Joho Tokumine ◽  
Odaka Yoshinobu ◽  
Hikaru Hama ◽  
...  

Background: Totally implantable venous access devices are valuable tools for total parenteral nutrition, chemotherapy, and long-term intravenous therapy. However, late catheter fracture is a well-known complication of totally implantable venous access device, particularly in Groshong silicone catheter. Recently, a specific type of totally implantable venous access device made with Groshong silicone has been introduced to facilitate power injection of contrast medium for enhanced computed tomography. Cases description: We reported three cases of catheter fracture in power-injectable Groshong silicone totally implantable venous access device. From May 2012 to August 2014, 66 patients underwent power-injectable Groshong silicone totally implantable venous access device implantation at our institution, with a median follow-up of 20.1 (range 0.2–58.1) months. The catheters in all patients were inserted into the internal jugular vein under ultrasound guidance and were connected to the port implanted in the upper chest through the subcutaneous tunnel. Chemotherapy was administered using these routes. Fractures of all three cases specifically showed a torn catheter section: smooth surface on one side, and a rough edge on the other side of the catheter, suggesting that long-term repeated stretch force may be related with the mechanism of fracture. Conclusion: Totally implantable venous access devices with Groshong silicone catheters, if inserted via the internal jugular vein, have a potential risk for late catheter fracture.


2018 ◽  
Vol 20 (1) ◽  
pp. 102-104 ◽  
Author(s):  
Hala Nas ◽  
Dedrick Bowe ◽  
Ayman O Soubani

Introduction: Totally implantable venous access devices are used extensively worldwide in cancer patients for administration of venotoxic agents, blood sampling, and nutrition. Their tip is usually positioned at the junction of superior vena cava and right atrium. Inferior vena cava filters are usually used for deep venous thrombosis in cases where anticoagulation is contraindicated; they can be inserted either via internal jugular or femoral access depending on patient conditions and preference. Case description: We are describing here a case of totally implantable venous access device fracture following a right internal jugular approach for inferior vena cava filter placement as the patient had inferior vena cava thrombus below the renal veins, extending into the right common iliac vein prohibiting femoral approach. Conclusion: Iatrogenic fracture of totally implantable venous access device is a potential complication of accessing the internal jugular vein for other procedures such as insertion of inferior vena cava filter.


2021 ◽  
Vol 14 (2) ◽  
pp. e239103
Author(s):  
Ponmani Agasthiya Manimaran ◽  
Prakash Agarwal ◽  
Madhu Ramasundaram ◽  
Jegadeesh Sundaram

Implantable venous access devices are routinely used, but they are not without complications. A 4-year-old male child with B cell acute lymphoblastic leukaemia was planned for chemotherapy. Chemo port was accessed through the right internal jugular vein. Check X-ray was done, which showed the correct placement of the catheter. Two months after chemo port insertion when the patient underwent chemotherapy, he developed a fever and he was started on intravenous antibiotics. On the next two admissions, the patient had a fever with chamber site oedema for which culture was done, which revealed Pseudomonas and Candida, which responded to antibiotic and antifungal therapies. In the successive admission, the patient had immediate local oedema on injecting chemotherapy. Exploration was done, which revealed chamber base perforation. It is an infrequent complication and has been reported in only three studies.


2021 ◽  
Vol 28 (2) ◽  
pp. 1495-1506
Author(s):  
Brent Burbridge ◽  
Hyun Lim ◽  
Lynn Dwernychuk ◽  
Ha Le ◽  
Tehmina Asif ◽  
...  

Introduction: Venous access is a crucial element in chemotherapy delivery. It remains unclear whether cancer patients prefer a port to a peripherally inserted central catheter (PICC). Our study aimed to assess cancer patients’ satisfaction with their venous access device and to compare the quality of life (QoL) of subjects with a PICC to those with a port. Methods: In this prospective cohort study, EORTC QLQ-C30, and a locally developed quality of life survey (QLAVD), designed to assess satisfaction with venous access devices, were administered to breast or colorectal cancer patients over a one-year period following the device insertion. Mixed effects models were used to assess changes on mean scores at different time points. Results: A total of 101 patients were recruited over a three-year period, (PICC group, n = 50; port group, n = 51). Survey response rates for months one and three were 72% and 48%, respectively. Overall, no significant differences were noted between the two groups in relation to EORTC QOL. At three months, the mean pain scores were 3.5 ± 2.3 for the port and 1.3 ± 0.75 for PICC (<0.001). The mean score for a negative effect of the venous access device on psychosocial well-being was 6.0 ± 4.1 for PICC and 3.0 ± 2.7 for the port (p = 0.005). Complications related to PICCs occurred in 38% patients versus 41% with a port (p > 0.24). Conclusions: Although subjects with a port experienced more pain during the device insertion or access for chemotherapy, it had a smaller negative impact on psychosocial scores than the PICC. No significant differences in complications rates were observed between the two devices.


Author(s):  
Miguel García-Boyano ◽  
José Manuel Caballero-Caballero ◽  
Marta García Fernández de Villalta ◽  
Mar Gutiérrez Alvariño ◽  
María Jesús Blanco Bañares ◽  
...  

Sign in / Sign up