A glassy carbon electrode modified with a film composed of cobalt oxide nanoparticles and graphene for electrochemical sensing of H2O2

2014 ◽  
Vol 181 (5-6) ◽  
pp. 631-638 ◽  
Author(s):  
Su-Juan Li ◽  
Ji-Min Du ◽  
Jia-Ping Zhang ◽  
Meng-Jie Zhang ◽  
Jing Chen
RSC Advances ◽  
2019 ◽  
Vol 9 (25) ◽  
pp. 14443-14451 ◽  
Author(s):  
Sidra Amin ◽  
Aneela Tahira ◽  
Amber Solangi ◽  
Valerio Beni ◽  
J. R. Morante ◽  
...  

We propose a new facile electrochemical sensing platform for determination of urea, based on a glassy carbon electrode (GCE) modified with nickel cobalt oxide (NiCo2O4) nanoneedles.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Pattan-Siddappa Ganesh ◽  
Ganesh Shimoga ◽  
Seok-Han Lee ◽  
Sang-Youn Kim ◽  
Eno E. Ebenso

Abstract Background A simple and simultaneous electrochemical sensing platform was fabricated by electropolymerization of allura red on glassy carbon electrode (GCE) for the interference-free detection of dihydroxy benzene isomers. Methods The modified working electrode was characterized by electrochemical and field emission scanning electron microscopy methods. The modified electrode showed excellent electrocatalytic activity for the electrooxidation of catechol (CC) and hydroquinone (HQ) at physiological pH of 7.4 by cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques. Results The effective split in the overlapped oxidation signal of CC and HQ was achieved in a binary mixture with peak to peak separation of 0.102 V and 0.103 V by CV and DPV techniques. The electrode kinetics was found to be adsorption-controlled. The oxidation potential directly depends on the pH of the buffer solution, and it witnessed the transfer of equal number of protons and electrons in the redox phenomenon. Conclusions The limit of detection (LOD) for CC and HQ was calculated to be 0.126 μM and 0.132 μM in the linear range of 0 to 80.0 μM and 0 to 110.0 μM, respectively, by ultra-sensitive DPV technique. The practical applicability of the proposed sensor was evaluated for tap water sample analysis, and good recovery rates were observed. Graphical abstract Electrocatalytic interaction of ALR/GCE with dihydroxy benzene isomers.


2021 ◽  
Author(s):  
Manjula Natesan ◽  
Shenming Chen

We demonstrated the simple and more accurate electrochemical sensor for isoprenaline (ISPT) analysis in pharmaceutical substances based on manganese cobalt oxide (MnCo2O4) modified with glassy carbon electrode (MCO/GCE). The nanomaterial...


Sign in / Sign up

Export Citation Format

Share Document