Treatment considerations for cervical and cervicothoracic spondylodiscitis associated with esophageal fistula due to cancer history or accidental injury: a 9-patient case series

2019 ◽  
Vol 161 (9) ◽  
pp. 1877-1886
Author(s):  
Insa Janssen ◽  
Ehab Shiban ◽  
Anna Rienmüller ◽  
Yu-Mi Ryang ◽  
Adam M. Chaker ◽  
...  
2019 ◽  
Vol 9 (6) ◽  
pp. 551-558 ◽  
Author(s):  
Jessica Oswald ◽  
Varun Shahi ◽  
Krishnan V Chakravarthy

Aim: This case series looks at outcomes in 39 patients implanted using the Bioness Stimrouter system on various isolated mononeuropathies. Patients & methods: A case series of 39 patients with a total of 42 implants were enrolled starting August 2017 at various pain management centers. Results: Of 39 patients studied, 78% of the participants noticed an improvement in their pain. There was a 71% reduction in pain scores with the average preprocedure score of 8 improving to 2 post-implant. Participants noted on average a 72% improvement in activity with the greatest observed in the brachial plexus (80%) and suprascapular nerve (80%) and smallest in the intercostal nerve (40%). Approximately 89% of those implanted with a peripheral nerve stimulator experienced a greater than 50% reduction in opioid consumption. Conclusion: Peripheral nerve stimulators are a new, minimally invasive neuromodulation modality that shows promising early results in our 39-patient case series.


2019 ◽  
Vol 39 (4) ◽  
pp. 469-477
Author(s):  
Marc Nevins ◽  
Marcelo Camelo ◽  
Anthony Prudenti ◽  
Soo-Woo Kim ◽  
Raquel Surette ◽  
...  

2020 ◽  
Vol 12 (1) ◽  
pp. e2020068
Author(s):  
Johanna Flach ◽  
Evgenii Shumilov ◽  
Naomi Porret ◽  
Inna Shakhanova ◽  
Myriam Legros ◽  
...  

Not applicable


Neurosurgery ◽  
2019 ◽  
Vol 87 (1) ◽  
pp. 53-62
Author(s):  
Jacob Cherian ◽  
Visish Srinivasan ◽  
Michael T Froehler ◽  
Jonathan A Grossberg ◽  
C Michael Cawley ◽  
...  

Abstract BACKGROUND Though the Pipeline Embolization Device (Medtronic) is approved for use in adults 22 yr and older, the high efficacy and long-term durability of the device is attractive for treatment of intracranial aneurysms in younger patients who often have aneurysms less amenable to traditional endovascular treatments. OBJECTIVE To report technical, angiographic, and clinical outcomes in patients aged 21 or below undergoing flow-diversion treatment for intracranial aneurysms. METHODS Retrospective review across 16 institutions identified 39 patients aged 21 or below undergoing 46 treatment sessions with Pipeline Embolization Device placement between 2012 and 2018. A total of 50 intracranial aneurysms were treated. Details regarding patient demographics, aneurysm characteristics, treatment considerations, clinical outcomes, and aneurysm occlusion were obtained and analyzed in a multicenter database. RESULTS A total of 70% of patients were male. Nonsaccular morphology was seen in half of identified aneurysms. Six aneurysms were giant, and five patients were treated acutely after ruptured presentation. Eight patients were younger than 10 yr of age. Complete aneurysm occlusion was seen in 74% of treated aneurysms. Three aneurysms (6%) were retreated. A total of 83% of patients had a modified Rankin Scale scores of ≤2 at last clinical follow-up. There were 2 early mortalities (4.3%) in the immediate postprocedure period because of rerupture of a treated ruptured aneurysm. No recanalization of a previously occluded aneurysm was observed. CONCLUSION Flow-diversion treatment is a safe and effective treatment for intracranial aneurysms in patients younger than 22 yr. Rates of complete aneurysm occlusion and adverse events are comparable for rates seen in older patients.


Sign in / Sign up

Export Citation Format

Share Document