scholarly journals Bridge from central extracorporeal life support is a risk factor of cerebrovascular accidents after durable left ventricular assist device implantation

Author(s):  
Kohei Tonai ◽  
Satsuki Fukushima ◽  
Naoki Tadokoro ◽  
Satoshi Kainuma ◽  
Naonori Kawamoto ◽  
...  

AbstractA bridging strategy from extracorporeal life support (ECLS) is effective in salvage and a bridge to recovery or to a durable left ventricular assist device (LVAD) for acute refractory heart failure. However, the correlation of this strategy with adverse events after durable LVAD implantation has not been fully investigated. This study enrolled 158 consecutive patients who had either the HeartMate II or HeartMate 3 and were implanted for bridge-to-transplantation. These devices were implanted as the primary mechanical support device in 115 patients, whereas the remaining 43 underwent LVAD implantation as the bridge from central ECLS. The primary study endpoint was all-cause mortality and cerebrovascular accidents (CVAs) after durable LVAD implantation, and the secondary endpoints were adverse events. Overall survival was not significantly different between the two groups. In contrast, the probability of CVAs was significantly greater in the bridge group than in the primary group (probability of CVAs, P = 0.002; log-rank test). In Cox multivariate logistic regression analysis, a bridge from central ECLS was an independent predictive factor of CVAs (hazard ratio 4.27, 95% confidence interval 1.43–12.8; P = 0.0095). Patients who are bridged from central ECLS are more frequently complicated by CVAs compared with those who undergo primary implantation of a durable LVAD, but survival is not significantly different between the two groups. A bridge from central ECLS is an independent predictive factor of CVAs post-implantation of an LVAD.

2019 ◽  
Vol 28 (2) ◽  
pp. 114-125
Author(s):  
A. Quessard ◽  
G. Cadier ◽  
J. Imbault ◽  
J. Rey ◽  
M. Pernot ◽  
...  

L’assistance monoventriculaire Impella® est une assistance microaxiale non pulsatile dépourvue de fonction d’oxygénation et/ou de décarboxylation. Sur le principe de la vis sans fin d’Archimède, elle aspire le sang dans le ventricule gauche pour le réinjecter dans la racine de l’aorte en regard des ostia coronaires. Selon le modèle utilisé, le débit d’assistance antérograde ainsi généré varie de 2,5 à 5 l/min. De par son mode de fonctionnement, l’assistance Impella® permet une décharge ventriculaire efficace. Ses indications sont l’angioplastie coronaire à haut risque et le choc cardiogénique réfractaire aux agents cardiovasoactifs. Chez le patient assisté par une extracorporeal life support (ECLS), la pompe Impella® permet de limiter le risque de surcharge ventriculaire. Chez le patient exclusivement assisté par Impella® soit d’emblée ou après une association avec l’ECLS, la voie d’abord axillaire permet sa réhabilitation active y compris la déambulation et l’activité physique. Elle se révèle alors une mise à l’épreuve cliniquement pertinente du ventricule droit en vue d’une assistance de longue durée de type left ventricular assist device.


Sign in / Sign up

Export Citation Format

Share Document