Evaluation of the low-level laser therapy application parameters for skin burn treatment in experimental model: a systematic review

2018 ◽  
Vol 33 (5) ◽  
pp. 1159-1169 ◽  
Author(s):  
Patricia Brassolatti ◽  
Ana Laura Martins de Andrade ◽  
Paulo Sérgio Bossini ◽  
Albaiza Nicoletti Otterço ◽  
Nivaldo Antônio Parizotto
2014 ◽  
Vol 2 (5) ◽  
pp. 376
Author(s):  
Priscila Leite ◽  
Nicole Melo ◽  
Pâmela Silva ◽  
Robinsom Montenegro ◽  
Paulo Bonan ◽  
...  

AIM: Conducting a systematic review of randomized clinical trials focusing on the efficacy of LLLT on pain control in patients with TMD, diagnosed by the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). MATERIAL AND METHODS: Search was performed at PubMed/MEDLINE database with the terms: (1) “Laser AND temporomandibular disorders”; (2) “Laser AND temporomandibular disorders AND RDC/TMD”; (3) “Low-level laser therapy AND temporomandibular disorders”; (4) “Low-level laser therapy AND temporomandibular disorders AND RDC/TMD”; (5) “Low-level laser therapy AND temporomandibular joint dysfuntion syndrome”; (6) “Low-level laser therapy AND temporomandibular joint dysfuntion syndrome AND RDC/TMD”; (7) “Laser AND temporomandibular joint dysfuntion syndrome” (8) “Laser AND RDC/TMD”; (9) “Low-level laser therapy AND RDC/TMD”. Inclusion criteria: articles need to be randomized clinical trial performed in humans; evaluate the effect of LLLT in the treatment of TMD diagnosed by the use of RDC/TMD; published in English or Portuguese in the last 10 years. Protocol studies and pilot studies were excluded. RESULTS: Ten studies were included. The type of laser used was Gallium Aluminum Arsenide (GaAlAs) diode, with exception of 1 paper, which used super pulsed Gallium Arsenide laser. Eight studies reported decreased in pain levels, in two articles there was no statistically significant difference between test and placebo groups. CONCLUSION: In most studies, LLLT was effective in pain remission, but there is no standardization in parameters like wavelength, output power and frequency. Studies with more complex experimental designs, standardized diagnostic criteria for TMD and defined protocols for the use of LLLT are needed to determine its efficacy in the treatment of TMD.


Author(s):  
Janice S. Guimarães ◽  
Fabio L. Arcanjo ◽  
Gustavo Leporace ◽  
Leonardo F. Metsavaht ◽  
Cristiano Sena ◽  
...  

2006 ◽  
Vol 21 (4) ◽  
pp. 258-262 ◽  
Author(s):  
Rodrigo Paschoal Prado ◽  
Richard Eloin Liebano ◽  
Bernardo Hochman ◽  
Carlos Eduardo Pinfildi ◽  
Lydia Masako Ferreira

PURPOSE: To develop an experimental model to be used in the study of low level Laser therapy on viability of random skin flap in rats. METHODS: The sample was 24 Wistar-EPM rats. The random skin flap measured 10 x 4 cm and a plastic sheet was interposed between the flap and donor site. Group 1 (control) underwent sham irradiation with diode laser (830 nm). Group 2 was submitted to laser irradiation with diode laser (830 nm). The animals were submitted to Laser therapy with 36 J/cm² energy density (72 seconds) immediately after the surgery and on the four subsequent days. The probe was usually held in contact with the skin flap surface on a point at 2.5 cm cranial from the flap base. On the seventh postoperative day, the percentage of necrotic area was measured and calculated. RESULTS: Group 1 reached an average necrotic area of 48.86%, Group 2 - 23.14%. After the statistic analysis, compared with the control group, Group 2 showed a statistically significant increase in survival area (p<0.001). CONCLUSION: The experimental model proved to be reliable to be used in the study of effects of low level laser therapy in random skin flap in rats.


Sign in / Sign up

Export Citation Format

Share Document