The reverse leak test for the assessment of low coloanal anastomosis: technical note

2019 ◽  
Vol 23 (5) ◽  
pp. 491-492 ◽  
Author(s):  
S. H. Emile ◽  
S. D. Wexner
Author(s):  
H. S. Kim ◽  
R. U. Lee

A heating element/electrical conduit assembly used in the Orbiter Maneuvering System failed a leak test during a routine refurbishment inspection. The conduit, approximately 100 mm in length and 12 mm in diameter, was fabricated from two tubes and braze-joined with a sleeve. The tube on the high temperature side (heating element side) and the sleeve were made of Inconel 600 and the other tube was stainless steel (SS) 316. For the filler metal, a Ni-Cr-B brazing alloy per AWS BNi-2, was used. A Helium leak test spotted the leak located at the joint between the sleeve and SS 316 tubing. This joint was dissected, mounted in a plastic mold, polished, and examined with an optical microscope. Debonding of the brazed surfaces was noticed, more pronounced toward the sleeve end which was exposed to uncontrolled atmospheric conditions intermittently. Initially, lack of wetting was suspected, presumably caused by inadequate surface preparation or incomplete fusion of the filler metal. However, this postulation was later discarded based upon the following observations: (1) The angle of wetting between the fillet and tube was small, an indication of adequate wetting, (2) the fillet did not exhibit a globular microstructure which would be an indication of insufficient melting of the filler metal, and (3) debonding was intermittent toward the midsection of the sleeve.


2012 ◽  
Vol 21 (1) ◽  
pp. 11-16 ◽  
Author(s):  
Susan Fager ◽  
Tom Jakobs ◽  
David Beukelman ◽  
Tricia Ternus ◽  
Haylee Schley

Abstract This article summarizes the design and evaluation of a new augmentative and alternative communication (AAC) interface strategy for people with complex communication needs and severe physical limitations. This strategy combines typing, gesture recognition, and word prediction to input text into AAC software using touchscreen or head movement tracking access methods. Eight individuals with movement limitations due to spinal cord injury, amyotrophic lateral sclerosis, polio, and Guillain Barre syndrome participated in the evaluation of the prototype technology using a head-tracking device. Fourteen typical individuals participated in the evaluation of the prototype using a touchscreen.


1998 ◽  
Vol 47 (3) ◽  
pp. 153-160
Author(s):  
Wang ◽  
Park ◽  
Kang ◽  
Oh
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document