Development and Validation of a Stability-Indicating RP-HPLC Method for Determination of Eprinomectin, its Degradation Products, and Butylated Hydroxytoluene in a Pour-On Finished Product

2021 ◽  
Vol 84 (10) ◽  
pp. 949-965
Author(s):  
Nilusha Padivitage ◽  
Lin Wang ◽  
Rasangi M. Wimalasinghe ◽  
Abu M. Rustum
INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (08) ◽  
pp. 48-52
Author(s):  
K. P Parekh ◽  
◽  
A. P. Jadhav

A simple, accurate, precise, robust stability indicating RP-HPLC method was developed and validated for simultaneous estimation of berberine and curcumin in an ayurvedic formulation. The two markers were resolved using a C-18 column using as the mobile phase methanol: water (pH 3 adjusted using acetic acid) in the ratio 75:25 V/V at a flow rate of 1mL/min. Retention times of berberine and curcumin were 2.58 ± 0.2 min and 8.5 ± 0.2 min, respectively at 358 nm. Linear response was observed in the concentration range of 2 – 8 ppm for berberine and 5 – 40 ppm for curcumin, with correlation coefficient (r2) of 0.994 and 0.998 for berberine and curcumin, respectively. The developed method was applied for quantitation of markers in marketed and in-house formulations of Gruhadhoomadi Churna. This method can also be used to evaluate formulations containing berberine and curcumin as markers, thus conforming to the need of ensuring quality and safety of herbal medicines.


2016 ◽  
Vol 9 (1) ◽  
pp. 54
Author(s):  
Megha Sharma ◽  
Neeraj Mahindroo

Objective: The objective of the present study was to develop and validate a novel stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for determination of β-acetyldigoxin, an active pharmaceutical ingredient (API).Methods: The chromatographic separation was carried out on Agilent Technologies 1200 series HPLC system equipped with photo diode array detector and C-18 (4.6x250 mm, 5 µ) column. The mobile phase consisted of water: acetonitrile (65:35 v/v), delivered at a flow rate of 1.5 ml/min and eluents were monitored at 225 nm.Results: The retention time of β-acetyldigoxin was 9.2 min. The method was found to be linear (R2= 0.9995) in the range of 31.25-500 µg/ml. The accuracy studies showed the mean percent recovery of 101.02%. LOD and LOQ were observed to be 0.289 µg/ml and 0.965 µg/ml, respectively. The method was found to be robust and system suitability testing was also performed. Forced degradation analysis was carried out under acidic, alkaline, oxidative and photolytic stress conditions. Significant degradation was observed under tested conditions, except for oxidative condition. The method was able to separate all the degradation products within runtime of 20 min and was able to determine β-acetyldigoxin unequivocally in presence of degradation products.Conclusion: The novel, economic, rapid and simple method for analysis of β-acetyldigoxin is reported. The developed method is suitable for routine quality control and its determination as API, and in pharmaceutical formulations and stability study samples.


2010 ◽  
Vol 93 (4) ◽  
pp. 1207-1214 ◽  
Author(s):  
Sejal K Patel ◽  
Natvarlal J Patel

Abstract This paper describes the development of a stability-indicating RP-HPLC method for the determination of atomoxetine hydrochloride (ATX) in the presence of its degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of acid, base, oxidation, wet heat, dry heat, and photodegradation. In stability tests, the drug was susceptible to acid, base, oxidation, and dry and wet heat degradation. It was found to be stable under the photolytic conditions tested. The drug was successfully separated from the degradation products formed under stress conditions on a Phenomenex C18 column (250 4.6 mm id, 5 m particle size) by using acetonitrilemethanol0.032 M ammonium acetate (55 + 05 + 40, v/v/v) as the mobile phase at 1.0 mL/min and 40C. Photodiode array detection at 275 nm was used for quantitation after RP-HPLC over the concentration range of 0.55 g/mL with a mean recovery of 100.8 0.4 for ATX. Statistical analysis demonstrated that the method is repeatable, specific, and accurate for the estimation of ATX. Because the method effectively separates the drug from its degradation products, it can be used as a stability-indicating method.