A Small Transition-Type Ionization Chamber with Anti-vibration Properties for Dose and Dose Power Monitoring during X-Ray Diagnosis

2014 ◽  
Vol 47 (5) ◽  
pp. 257-258
Author(s):  
L. V. Vladimirov ◽  
A. A. Kozlov ◽  
A. N. Cherniy
2012 ◽  
Vol 46 (2) ◽  
pp. 50-52
Author(s):  
L. V. Vladimirov ◽  
S. G. Gorra ◽  
B. M. Kanter ◽  
A. A. Kozlov ◽  
Y. N. Kopanev ◽  
...  

2011 ◽  
Vol 11 (3) ◽  
pp. 184-188
Author(s):  
Syed F. Akber ◽  
Than S. Kehwar

AbstractThe partial volume (spatial) response of four ionization chambers (Keithley) in kilovoltage X-ray beams, generated by the Philips Super 80CP X-ray unit, was assessed. The volume of the ionization chambers were of 10 cm3, 15 cm3, 150 cm3, and 600 cm3 used with Keithley electrometer Model 35040. The beam output was measured using a monitor chamber (Radcal 6.0 cm3) placed close to the collimator. The source to chamber distance was kept constant at 1 m. For the measurement of the response of ionization chambers of 15 cm3, 150 cm3, and 600 cm3, a slit of 2.0 mm width was made in a lead sheet of 3.2 mm thick and size of 30 × 30 cm2 and was placed on the ionization chamber. The measurements were made for 81 kVp, 400 mA, and 0.25 s and the slit was moved at an increment of 2.0 mm over the entire length of the chamber. For the measurements of the ionization chamber of 10 cm3 (CT chamber), the beams of 120 kVp, 200 mA and 0.2 s were generated, and a slit of 5 mm width was made in a similar lead sheet that was moved at an increment of 5.0 mm. From the result it appears that the sensitive volumes of the ionization chambers affect the response of the ionization chamber to incident radiation.


2006 ◽  
Vol 49 (spe) ◽  
pp. 17-23 ◽  
Author(s):  
Carlos de Austerlitz ◽  
Viviane Souza ◽  
Heldio Pereira Villar ◽  
Aloisio Cordilha

The performance of four X-ray qualities generated in a Pantak X-ray machine operating at 30-100 kV was determined with a parallel-plate ionization chamber and a Fricke dosimeter. X-ray qualities used were those recommended by Deutsch Internationale Normung DIN 6809 and dose measurements were carried out with Plexiglas® simulators. Results have shown that the Fricke dosimeter can be used not only for soft X-ray dosimetry, but also for the maintenance of low-energy measuring systems' calibration factor.


2013 ◽  
Vol 425 (17) ◽  
pp. 172001 ◽  
Author(s):  
T Tanaka ◽  
T Kuwada ◽  
Y Takahashi ◽  
K Hayakawa ◽  
Y Hayakawa ◽  
...  

2016 ◽  
Vol 186 (3) ◽  
pp. 283-291 ◽  
Author(s):  
Joseph T. Rakowski ◽  
Mark A. Tucker ◽  
Michael G. Snyder ◽  
Simon P. Makar ◽  
Mark Yudele ◽  
...  
Keyword(s):  

1959 ◽  
Vol 14 (10) ◽  
pp. 1321-1327 ◽  
Author(s):  
Kenzo Tanaka ◽  
Jun-ichi Chikawa ◽  
Tadashi Yamanaka
Keyword(s):  
X Ray ◽  

Radiology ◽  
1930 ◽  
Vol 15 (1) ◽  
pp. 49-65 ◽  
Author(s):  
Lauriston S. Taylor

Sign in / Sign up

Export Citation Format

Share Document