Using a modified version of Airpacts model for estimating the damage posed by sulfur dioxide emission from power plants to urban and rural building façades (case study: Shahid Rajaee power plant, Qazvin Province, Iran)

2021 ◽  
Vol 193 (7) ◽  
Author(s):  
E. Mojaver ◽  
S. Sobhanardakani ◽  
F. Moattar ◽  
S. A. Jozi ◽  
S. M. Monavari
2012 ◽  
Vol 2 (8) ◽  
pp. 1-9
Author(s):  
Saroj Koul

Subject area Operations and human resourcing. Study level/applicability This case study is intended for use in graduate, executive level management and doctoral programs. The case study illustrates a combined IT and HR driven participative management control system in a flexible organization structure. It is intended for a class discussion rather than to illustrate either effective or ineffective handling of an administrative situation. Case overview The case describes the situation of managing unskilled workforces (≥14,000 workers) during the construction phase of the 4 × 250MW power plants both for purposes of turnout as well as due compensation, in the event of an accident. The approved labour forces appointed for 45 × 8 h. Man-days after a rigorous fitness test and approvals of the safety officer are allocated housing and other necessary amenities and a commensurate compensation system. Expected learning outcomes These include: illustrating typical organizational responsibility structure at a construction site of a large power plant; illustrating the planning and administrative control mechanism in implementing strategy at a construction site of a large power plant; offering students the opportunity to understand and view a typical operational (project) structure; allowing students to speculate adaptations in the wake of an ever-changing business and company environment; and providing an opportunity to introduce a power scenario in India, Indian labour laws and radio frequency identification technology and to relate this to the case in context. Supplementary materials Teaching notes are available; please consult your librarian for access.


Author(s):  
Antonio Messineo ◽  
Domenico Panno ◽  
Roberto Volpe

Biomass can provide a reliable support for production of biofuels while contributing to sustainable management of natural resources. Many countries, including Italy, have introduced important incentive schemes to support the use of biomass for electricity, heat and transportation. This has raised considerable interest towards the use of biomass for energy generation purposes. Nonetheless, the design and installation of biomass-fuelled power plants present several critical issues, such as choice and availability of biomass, choice of technology, power plant localization and logistics. The case study tackled in this paper evaluates the economies originated by a 1MWel Organic Rankine Cycle (ORC) turbine coupled with a biomass fuelled boiler, installed in an area close to Palermo (Italy). A Geographical Information System (GIS) was used to localize the power plant and to optimize logistics. The thermodynamics of the plant as a whole were also analyzed. Finally, two different scenarios were simulated for project financial evaluation.


Author(s):  
Komandur S. Sunder Raj

The objectives of an effective power plant performance monitoring program are several-fold. They include: (a) assessing the overall condition of the plant through use of parameters such as output and heat rate (b) monitoring the health of individual components such as the steam generator, turbine-generator, feedwater heaters, moisture separators/reheaters (nuclear), condenser, cooling towers, pumps, etc. (c) using the results of the program to diagnose the causes for deviations in performance (d) quantifying the performance losses (e) taking timely and cost-effective corrective actions (f) using feedback techniques and incorporating lessons learned to institute preventive actions and, (g) optimizing performance. For the plant owner, the ultimate goals are improved plant availability and reliability and reduced cost of generation. The ability to succeed depends upon a number of factors such as cost, commitment, resources, performance monitoring tools, instrumentation, training, etc. Using a case study, this paper discusses diagnostic techniques that might aid power plants in improving their performance, reliability and availability. These techniques include performance parameters, supporting/refuting matrices, logic trees and decision trees for the overall plant as well as for individual components.


Author(s):  
Jerry A. Kopczynski ◽  
Bill Dickson ◽  
Gerhard J. Weiss

The scope of modern power plant controls usually includes plant DCS, boiler control and protection, steam/gas turbine governor and protection, auxiliaries control, automatic voltage controller, automatic synchronizer and operator/engineering stations. Usually these control packages come from different manufacturers (OEM). They are typically based on various electronic hardware and software platforms. Different communication protocols often present problems during system integration; and maintenance costs of these various electronic hardware and software platforms are normally greater than that of a stand alone system. Advantages of an integrated, distributed, open architecture, digital system, (Fig. 1) which covers all the power plant needs are discussed in this paper. A common electronic hardware/ software platform allows optimization of the new constructions and upgrades, shorten delivery and commissioning time, and improve availability and safety of the new and upgraded power plants. Specific benefits of this concept are presented in the Mt. Poso controls upgrade Case Study. The common electronic hardware/ software platform installed at Mt. Poso allowed optimization of the upgrade, shortened commissioning time, improved availability, reliability and safety and reduced maintenance cost of the control systems.


Author(s):  
Antonio Mambro ◽  
Francesco Congiu ◽  
Francesco Piraccini

Abstract The continuous increase of variable renewable energy and fuel cost requires steam turbine power plants to operate with high flexibility. Furthermore, the reduction in electricity price is forcing many existing and new district heating power plants to further optimize the heat production to maintain a sustainable business. This situation leads to low pressure steam turbines running at very low volume flow for an extended time. In this work, a case study of an existing 30 MWel district heating power plant located in Europe is presented. The customer request was the removal of the steam turbine last two stages along with the condenser to maximize steam delivery for district heating operations. However, based on the experience gained by GE on low load during the last years, the same heat production has been guaranteed without any significant impact on the existing unit, excluding any major modification of the plant layout such as last stage blading and condenser removal. Making use of the latest low flow modeling, the minimum cooling flow through the low-pressure turbine has been reduced by more than 90% compared to the existing unit. Optimization of the hood spray system and logic will reduce trailing edge erosion during low load operation leading to a significant extension in the last stage blade lifetime. These modifications, commercialized by GE as the Advanced Low Load Package (ALLP), provide a cheap, flexible and effective solution for the customer. With today’s knowledge, GE has the capability to guarantee low load operation minimizing the mass flow through the low-pressure turbine to the minimum required for safe operation. As a benefit to the customer, this option allows a gain in operational income of about 1.5 M€ per year.


2021 ◽  
Vol 23 (1) ◽  
pp. 51
Author(s):  
Ari Nugroho ◽  
Eko Kusratmoko ◽  
Tito L. Indra

PREFERRED SITE SELECTION USING GIS AND AHP: CASE STUDY IN BANGKA ISLAND NPP SITE. Industrial growth affects the increasing demand for electricity in various places, this also occurs on the island of Bangka. So far, electricity supply has only been obtained from fossil fuel power plants with inadequate capacity, unstable flow and depending on fuel supplies from outside the island. For this reason, it is necessary to build a Nuclear Power Plant (PLTN) which is believed to be reliable and able to overcome these problems. In order to prepare a safe and economical nuclear power plant site, influential parameters such as population density, cooling system, land clearing, cut and fill, and granite for the foundation have been analyzed. The novelty of this analysis lies in 2 methods which gradually used before come up with a final decision, namely spatial analysis and pairwise comparison using Geographic Information Systems (GIS) and Analytical Hierarchy Process (AHP), respectively. The scope of study area is based on the site vicinity (1:5.000) scale, located in the districts of West and South Bangka. The siting process refers to the rules set by the International Atomic Energy Agency (IAEA). Based on the final results of the analysis using the expert choice program, the numerical weights for West Bangka and South Bangka were 0.709 and 0.291, respectively, with a consistency value of 0.03.


2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Tamás János Katona

Design of nuclear power plant shall provide an adequate margin to protect items ultimately necessary to prevent an early large radioactive release in the case of earthquakes exceeding those considered in the design. An essential question is how large the margin should be to be accepted as adequate. In the practice, depending on the country regulation, a plant margin of at least 1.4 or 1.67 times the design basis peak ground acceleration is required to be demonstrated. The catastrophe at the Fukushima Daiichi Nuclear Power Plant revealed the fundamental experience that the plants designed in compliance with nuclear standards can survive the effects of the vibratory ground motion due to disastrous earthquake but may fail due to effects of phenomena accompanying or generated by the earthquakes. Liquefaction is one of those secondary effects of beyond-design basis earthquakes that should be investigated for NPPs at soil sites. However, the question has not been investigated up to now, whether a “margin earthquake”, vibratory effects of which the plant can withstand thanks to design margin, will not induce liquefaction at soil sites and will not result in loss of safety functions. In the paper, a procedure is proposed for calculation of the probability and margin to liquefaction. Use of the procedure is demonstrated on a case study with realistic site-plant parameters. Criteria for probability for screening and acceptable probabilistic margin to liquefaction are proposed. The possible building settlement due to margin earthquake is also assessed.


Sign in / Sign up

Export Citation Format

Share Document