Elimination of the negative component of the unipolar electrogram as a local procedural endpoint during paroxysmal atrial fibrillation catheter ablation using contact-force sensing: the UNIFORCE study

2017 ◽  
Vol 49 (3) ◽  
pp. 299-306 ◽  
Author(s):  
Agustín Bortone ◽  
Philippe Lagrange ◽  
Bruno Cauchemez ◽  
Cyril Durand ◽  
Pierre Dieuzaide ◽  
...  
2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Ukita ◽  
A Kawamura ◽  
H Nakamura ◽  
K Yasumoto ◽  
M Tsuda ◽  
...  

Abstract Background Little has been reported on the outcome of contact force (CF)-guided radiofrequency catheter ablation (RFCA) and second generation cryoballoon ablation (CBA). Purpose The purpose of this study was to compare the outcome of CF-guided RFCA and second generation CBA for paroxysmal atrial fibrillation (PAF). Methods We enrolled the consecutive 364 patients with PAF who underwent initial ablation between September 2014 and July 2018 in our hospital. We compared the late recurrence of atrial tachyarrhythmia more than three months after ablation between RFCA group and CBA group. All RFCA procedures were performed using CF-sensing catheter and all CBA procedures were performed using second generation CB. Results There were significant differences in background characteristics: chronic kidney disease, serum brain natriuretic peptide level, and left ventricular ejection fraction. After propensity score matched analysis (Table), atrial tachyarrhythmia free survival was significantly higher in CBA group than in RFCA group (Figure). Conclusions Second generation CBA showed a significantly lower late recurrence rate compared to CF-guided RFCA. Kaplan-Meier Curve Funding Acknowledgement Type of funding source: None


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
H Ramanna ◽  
J L Lloret ◽  
F Zahwe ◽  
C Porterfield ◽  
S Trines ◽  
...  

Abstract Background Although pulmonary vein isolation (PVI) is considered the standard approach of atrial fibrillation ablation worldwide, procedural practice during the ablation varies by geographical region. Using the same magnetic sensor enabled contact force-sensing ablation catheter for the treatment of de novo paroxysmal atrial fibrillation, a comparison of procedural detail between Europe and U.S operators can provide insights into geographic specific clinical practices.  Purpose To characterize and compare procedural differences during paroxysmal atrial fibrillation ablation performed with a magnetic sensor enabled contact force-sensing catheter across European and U.S. centers.  Methods Procedural data were prospectively collected in clinical cases performed with a new magnetic sensor enabled, contact force ablation catheter within the first 6 months of use at participating centers in Europe and the U.S. Procedure time, PVI time, PVI confirmation method, fluoroscopy usage and lesion delivery parameters were analyzed based on geographies.  Results A total of 131 cases across 35 centers in 11 European countries, and 95 cases across 26 U.S. centers were analyzed. Target geometry was created with the ablation catheter in 94 out of 131 (71.8%) European cases, while only 5 out of 95 U.S. cases (5.3%) reported the use of the ablation catheter for model creation. Although a steerable sheath (64.1% and 67.3%) was commonly used with the ablation catheter in both geographies, difference in the utilization of bidirectional contact force catheter (52.7% and 90.5%) and the automated lesion marking module (76.3% and 81.1%) were observed in European and U.S. cases, respectively. The use of adenosine or isoproterenol to confirm PVI was reported in 25% and 64% of the European and U.S. cases. Average waiting periods were 18.2 minutes and 26.5 minutes from reported European and U.S. cases. Total procedural time, mapping time, and fluoroscopy time were similar between European and U.S. cases. (Table). First pass PVI were 66.4% and 72.6% for European and U.S. cases, respectively. Conclusion Total procedural time and RF time were similar between European and U.S. cases during de novo paroxysmal atrial fibrillation ablation using the same ablation catheter. Differences in workflow including the use of a mapping catheter for geometry creation and waiting period were observed between the two geographies. Summary of procedural details De novo PAF N Procedural time(min) Mapping time (min) PVI time (min) Total RF time (min) Fluoro time( min) Europe 131 144.0 ± 56.9 16.6 ± 17.1 69.8 ± 35.0 33.2 ± 15.6 11.6 ± 10.1 U.S. 95 137.6 ± 64.8 18.1 ± 23.5 58.8 ± 31.5 32.3 ± 22.2 12.0 ± 15.8


Sign in / Sign up

Export Citation Format

Share Document