scholarly journals Ablation of paroxysmal atrial fibrillation using a second-generation cryoballoon catheter or contact-force sensing radiofrequency ablation catheter: A comparison of costs and long-term clinical outcomes

2017 ◽  
Vol 29 (2) ◽  
pp. 284-290 ◽  
Author(s):  
Miki Yokokawa ◽  
Aman Chugh ◽  
Rakesh Latchamsetty ◽  
Hamid Ghanbari ◽  
Thomas Crawford ◽  
...  
EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
H Ramanna ◽  
J L Lloret ◽  
F Zahwe ◽  
C Porterfield ◽  
S Trines ◽  
...  

Abstract Background Although pulmonary vein isolation (PVI) is considered the standard approach of atrial fibrillation ablation worldwide, procedural practice during the ablation varies by geographical region. Using the same magnetic sensor enabled contact force-sensing ablation catheter for the treatment of de novo paroxysmal atrial fibrillation, a comparison of procedural detail between Europe and U.S operators can provide insights into geographic specific clinical practices.  Purpose To characterize and compare procedural differences during paroxysmal atrial fibrillation ablation performed with a magnetic sensor enabled contact force-sensing catheter across European and U.S. centers.  Methods Procedural data were prospectively collected in clinical cases performed with a new magnetic sensor enabled, contact force ablation catheter within the first 6 months of use at participating centers in Europe and the U.S. Procedure time, PVI time, PVI confirmation method, fluoroscopy usage and lesion delivery parameters were analyzed based on geographies.  Results A total of 131 cases across 35 centers in 11 European countries, and 95 cases across 26 U.S. centers were analyzed. Target geometry was created with the ablation catheter in 94 out of 131 (71.8%) European cases, while only 5 out of 95 U.S. cases (5.3%) reported the use of the ablation catheter for model creation. Although a steerable sheath (64.1% and 67.3%) was commonly used with the ablation catheter in both geographies, difference in the utilization of bidirectional contact force catheter (52.7% and 90.5%) and the automated lesion marking module (76.3% and 81.1%) were observed in European and U.S. cases, respectively. The use of adenosine or isoproterenol to confirm PVI was reported in 25% and 64% of the European and U.S. cases. Average waiting periods were 18.2 minutes and 26.5 minutes from reported European and U.S. cases. Total procedural time, mapping time, and fluoroscopy time were similar between European and U.S. cases. (Table). First pass PVI were 66.4% and 72.6% for European and U.S. cases, respectively. Conclusion Total procedural time and RF time were similar between European and U.S. cases during de novo paroxysmal atrial fibrillation ablation using the same ablation catheter. Differences in workflow including the use of a mapping catheter for geometry creation and waiting period were observed between the two geographies. Summary of procedural details De novo PAF N Procedural time(min) Mapping time (min) PVI time (min) Total RF time (min) Fluoro time( min) Europe 131 144.0 ± 56.9 16.6 ± 17.1 69.8 ± 35.0 33.2 ± 15.6 11.6 ± 10.1 U.S. 95 137.6 ± 64.8 18.1 ± 23.5 58.8 ± 31.5 32.3 ± 22.2 12.0 ± 15.8


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S130
Author(s):  
Moussa Mansour ◽  
Francis Marchlinski ◽  
Srinivas Dukkipati ◽  
Byron J. Colley ◽  
Jingyun Li ◽  
...  

EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
H Ramanna ◽  
J L Lloret ◽  
F Zahwe ◽  
C Porterfield ◽  
S Trines ◽  
...  

Abstract Background Accurate delivery of transmural lesion is associated with improved durability of pulmonary vein isolation and reduced reconduction. Lesion quality depends on multiple parameters such as radiofrequency power, tissue-catheter contact, duration of energy application, and catheter tip temperature. Consequently, energy delivery parameters vary based on individual operators’ preferences and procedural needs. Purpose To characterize and compare the utilization of automated lesion marking feature and lesion delivery parameters used during paroxysmal atrial fibrillation ablation performed with a magnetic sensor enabled contact force-sensing catheter across European and U.S. centers. Methods Procedural data were prospectively collected in clinical cases performed with a new magnetic sensor enabled, contact force ablation catheter within the first 6 months of use at participating centers in Europe and the U.S. Use of bidirectional CF catheters, steerable sheaths, automated lesion marking software and associated lesion delivery parameters during paroxysmal atrial fibrillation ablation were evaluated. Results A total of 149 cases across 37 centers in 11 European countries, and 112 cases across 31 U.S. centers were analyzed. A bidirectional contact force catheter (56.4% and 90.2%), a steerable sheath (65.8% and 69.6%), and the automated lesion marking module (77.9% and 90.2%) were used in most European and U.S. cases, respectively. The most commonly reported energy delivery parameters were: lesion index (LSI), Force-Time Integral (FTI), and time from European cases; LSI, average force, and FTI for U.S. cases (Table). Target LSI values were recorded for 126 cases in Europe and 34 in the U.S, ranging from 3 to 6. In anterior/roof segments, most common LSI target values for anterior/roof and posterior/inferior segments were 6 (42.9%) and 5 (51.2%) in Europe, and 5.5 (44.1%) and 5 (54.5%) in the U.S. PVI was confirmed with an average of 20.3 minutes waiting period (69.1%) for European cases and exit block (57.1%) in U.S. cases. First pass PVI were 67.1% and 74.4% for European and U.S. cases, respectively. Conclusion Energy delivery parameters and PVI confirmation method varied considerably by geography during paroxysmal atrial fibrillation ablation using the magnetic sensor enabled, contact force ablation catheter. Further study on efficacy implication on these differences in practice should be examined. Energy delivery parameters used Paroxysmal AF N LSI FTI Time Imp Drop Avg Force Other N/A Europe 149 44.0 % 13.4 % 7.0 % 6.0 % 2.4 % 1.0 % 26.2 % U.S. 112 31.2% 17.9 % 6.2 % 8.0 % 23.2 % 11.7 % 1.8 % Energy delivery parameters used in paroxysmal AF ablation in Europe and U.S.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
K Ukita ◽  
A Kawamura ◽  
H Nakamura ◽  
K Yasumoto ◽  
M Tsuda ◽  
...  

Abstract Background Little has been reported on the outcome of contact force (CF)-guided radiofrequency catheter ablation (RFCA) and second generation cryoballoon ablation (CBA). Purpose The purpose of this study was to compare the outcome of CF-guided RFCA and second generation CBA for paroxysmal atrial fibrillation (PAF). Methods We enrolled the consecutive 364 patients with PAF who underwent initial ablation between September 2014 and July 2018 in our hospital. We compared the late recurrence of atrial tachyarrhythmia more than three months after ablation between RFCA group and CBA group. All RFCA procedures were performed using CF-sensing catheter and all CBA procedures were performed using second generation CB. Results There were significant differences in background characteristics: chronic kidney disease, serum brain natriuretic peptide level, and left ventricular ejection fraction. After propensity score matched analysis (Table), atrial tachyarrhythmia free survival was significantly higher in CBA group than in RFCA group (Figure). Conclusions Second generation CBA showed a significantly lower late recurrence rate compared to CF-guided RFCA. Kaplan-Meier Curve Funding Acknowledgement Type of funding source: None