A Superposed Model for the Pipe Failure Assessment of Water Distribution Networks and Uncertainty Analysis: A Case Study

2018 ◽  
Vol 32 (5) ◽  
pp. 1713-1723 ◽  
Author(s):  
Qiang Xu ◽  
Zhimin Qiang ◽  
Qiuwen Chen ◽  
Kuo Liu ◽  
Nan Cao
2020 ◽  
Vol 20 (3) ◽  
pp. 878-888 ◽  
Author(s):  
J. Marques ◽  
M. Cunha

Abstract This work presents a multicriteria approach to defining flexible solutions for reinforcing and renewing existing water distribution networks, considering uncertain future working conditions. Criteria related to financial, environmental and pipe failure assessment are proposed to evaluate alternative solutions and to identify the best-placed options to implement. The alternatives are obtained for a phased design scheme that enables midcourse corrections through changes in the network layout. The proposed framework has been demonstrated using a case study based on a water distribution network from the literature.


Author(s):  
Aly-Joy Ulusoy ◽  
Filippo Pecci ◽  
Ivan Stoianov

AbstractThis manuscript investigates the design-for-control (DfC) problem of minimizing pressure induced leakage and maximizing resilience in existing water distribution networks. The problem consists in simultaneously selecting locations for the installation of new valves and/or pipes, and optimizing valve control settings. This results in a challenging optimization problem belonging to the class of non-convex bi-objective mixed-integer non-linear programs (BOMINLP). In this manuscript, we propose and investigate a method to approximate the non-dominated set of the DfC problem with guarantees of global non-dominance. The BOMINLP is first scalarized using the method of $$\epsilon $$ ϵ -constraints. Feasible solutions with global optimality bounds are then computed for the resulting sequence of single-objective mixed-integer non-linear programs, using a tailored spatial branch-and-bound (sBB) method. In particular, we propose an equivalent reformulation of the non-linear resilience objective function to enable the computation of global optimality bounds. We show that our approach returns a set of potentially non-dominated solutions along with guarantees of their non-dominance in the form of a superset of the true non-dominated set of the BOMINLP. Finally, we evaluate the method on two case study networks and show that the tailored sBB method outperforms state-of-the-art global optimization solvers.


2014 ◽  
Vol 89 ◽  
pp. 1545-1552 ◽  
Author(s):  
V. Ruzza ◽  
E. Crestani ◽  
G. Darvini ◽  
P. Salandin

2017 ◽  
Author(s):  
Stelios G. Vrachimis ◽  
Demetrios G. Eliades ◽  
Marios M. Polycarpou

Abstract. Hydraulic state estimation in water distribution networks is the task of estimating water flows and pressures in the pipes and nodes of the network based on some sensor measurements. This requires a model of the network, as well as knowledge of demand outflow and tank water levels. Due to modeling and measurement uncertainty, standard state-estimation may result in inaccurate hydraulic estimates without any measure of the estimation error. This paper describes a methodology for generating hydraulic state bounding estimates based on interval bounds on the parametric and measurement uncertainties. The estimation error bounds provided by this method can be applied to estimate the unaccounted-for water in water distribution networks. As a case study, the method is applied to a transport network in Cyprus, using actual data in real-time.


2020 ◽  
Vol 2 (1) ◽  
pp. 59
Author(s):  
Joaquim Sousa ◽  
Nuno Martinho ◽  
João Muranho ◽  
Alfeu Sá Marques

Leakage in water distribution networks (WDN) is still a major concern for water companies. In recent years, the scientific community has dedicated some effort to the leakage calibration issue to obtain accurate models. But leakage modelling implies the use of a pressure-driven approach as well as specific data to define the pressure/leakage relationship. This paper presents the calibration process of a real case study WDN model. The process started with pressure step tests, the model was built in WaterNetGen and the leakage calibration process was performed by a simulated annealing algorithm. As illustrated, after calibration the model was able to produce accurate results.


Proceedings ◽  
2018 ◽  
Vol 2 (11) ◽  
pp. 672 ◽  
Author(s):  
Attilio Fiorini Morosini ◽  
Olga Caruso ◽  
Paolo Veltri

The correct management of Water Distribution Networks (WDNs) allows to obtain a reliable system. When a pipe failure occurs in a network and it is necessary to isolate a zone, it is possible that some nodes do not guarantee service for the users due to inadequate heads. In these conditions a Pressure Driven Analysis (PDA) is the correct approach to evaluate network behavior. This analysis is more appropriate than the Demand Driven Analysis (DDA) because it is known that the effective delivered flow at each node is influenced by the pressure value. In this case, it is important to identify a subset of isolation valves to limit disrupting services in the network. For a real network, additional valves must be added to existing ones. In this paper a new methodological analysis is proposed: it defines an objective function (OF) to provide a measure of the system correct functioning. The network analysis using the OF helps to choose the optimal number of additional valves to obtain an adequate system control. In emergency conditions, the OF takes into account the new network topology obtained excluding the zone where the broken pipe is located. OF values depend on the demand deficit caused by the head decrement in the network nodes for each pipe burst considered. The results obtained for a case study confirm the efficiency of the methodology.