Successful endovascular treatment of an ascending aortic pseudoaneurysm using an Amplatzer Vascular Plug II

2020 ◽  
Vol 69 (1) ◽  
pp. 91-93 ◽  
Author(s):  
Takuya Matsuzawa ◽  
Mio Kasai ◽  
Kentaro Yamabe ◽  
Yu Inaba ◽  
Michiko Aoki ◽  
...  
2019 ◽  
Vol 2 (1) ◽  
Author(s):  
Umut Oguslu ◽  
Sadik Ahmet Uyanik ◽  
Burçak Gümüş

Abstract Background Hepatic arterioportal fistulas are rare, abnormal, direct communications between hepatic artery and portal venous system. Treatment options shifted from surgery to endovascular interventions. Catheterization may be challenging. We report a case of a hepatic arterioportal fistula treated successfuly with Amplatzer Vascular Plug II via percutaneous transhepatic hepatic artery access after failed transfemoral approach. Case presentation 58 year old woman presented with right heart failure, kidney insufficiency and massive ascites related to portal hypertension caused by hepatic arterioportal fistula. She had a history of previous abdominal surgery. Colour Doppler ultrasound and computed tomography revealed a giant portal vein aneurysm related to large hepatic areterioportal fistula. Endovascular treatment was planned. Catheterization of the hepatic artery could not be realized due to severe tortuosity and angulation of the celiac artery and its branches. Access to the hepatic artery was obtained directly via percutaneous transhepatic route and fistula site was embolized with Amplatzer Vascular Plug II and coils. Immediate thrombosis of the aneurysm sac and draining portal vein was observed. Patients clinical status improved dramatically. Conclusion Transcatheter embolization is the first choice of the treatment of hepatic arterioportal fistulas but the type of the therapy should be tailored to the patient and interventional radiologist should decide the access site depending on his own experience if the routine endovascular access can not be obtained.


2014 ◽  
Vol 48 (4) ◽  
pp. 329-332 ◽  
Author(s):  
Diederick W. De Boo ◽  
Nigel Mott ◽  
Helen Kavnoudias ◽  
Antony Walton ◽  
Stuart M. Lyon

2010 ◽  
Vol 17 (4) ◽  
pp. 564-568 ◽  
Author(s):  
Pasquale Mordasini ◽  
Gerhard Schroth ◽  
Caspar Brekenfeld ◽  
Christian Fung ◽  
Hanno Hoppe ◽  
...  

2021 ◽  
pp. 1-3
Author(s):  
Ahmet Vedat Kavurt ◽  
İbrahim Ece ◽  
Denizhan Bağrul

Abstract Acquired and congenital left ventricular to right atrial communication is rare, but nowadays, the frequency of the iatrogenic subgroup is increasing. Successful transcatheter closure of these defects with different devices has been reported. Herein, we presented successful closure of left ventricular to right atrial communication with Amplatzer Duct Occluder 2 after attempting to close with a failed Amplatzer Vascular Plug II device in a 7-year-old girl. This report supports that transcatheter closure of iatrogenic Gerbode defect with Amplatzer Duct Occluder 2 device is safe and effective.


2020 ◽  
Vol 30 (2) ◽  
pp. 243-248 ◽  
Author(s):  
Sneha M. Jain ◽  
Priya M. Pradhan ◽  
Supratim Sen ◽  
Bharat V. Dalvi

AbstractObjective:To evaluate the feasibility, efficacy, and safety of Amplatzer vascular plug II in large and elongated ducts in infants.Introduction:Patent arterial duct device closure is technically challenging in infants with large and elongated ducts because Amplatzer duct occluder and Amplatzer duct occluder II have high chances of causing aortic coarctation and left pulmonary artery stenosis, respectively. The Amplatzer vascular plug II being soft with no retention discs on either sides helps in mitigating these problems.Method:This is a prospective, observational study involving infants with clinical, echocardiographic and angiographic evidence of large left to right shunt. All the children underwent duct closure using Amplatzer vascular plug II.Results:Eighteen infants qualified for the study. Mean age and weight were 8.63 ± 3.84 months and 6.3 ± 1.7 kg, respectively. The angiographic mean duct diameter at the pulmonary artery end was 4.66 ± 0.92 mm, and the mean duct length was 9.4 ± 2.48 mm. The size of Amplatzer vascular plug II used varied from 6 mm to 10 mm. Technical success was achieved in 16/18 cases. One patient had device embolisation, and in the other, the device was found to be unstable. The ratio of Amplatzer vascular plug II size to the duct diameter was 1.65 ± 0.27, while the ratio of ductal length to device length was 1.48 ± 0.46 in those with successful outcome.Conclusions:Amplatzer vascular plug II is a safe and effective option in appropriately selected infants with elongated ducts. Diameter and length of Amplatzer vascular plug II vis-a-vis those of the ductus are important determinants of the successful outcome.


Sign in / Sign up

Export Citation Format

Share Document