The amplatzer vascular plug and amplatzer vascular plug II for vascular occlusion procedures in 50 patients with congenital cardiovascular disease

2009 ◽  
Vol 76 (3) ◽  
pp. 411-417 ◽  
Author(s):  
Matthew Schwartz ◽  
Andrew C. Glatz ◽  
Jonathan J. Rome ◽  
Matthew J. Gillespie
Vascular ◽  
2021 ◽  
pp. 170853812110251
Author(s):  
Umberto M Bracale ◽  
Anna Petrone ◽  
Michele Provenzano ◽  
Nicola Ielapi ◽  
Liborio Ferrante ◽  
...  

Objectives The Amplatzer Vascular Plug (AVP) is a vascular occlusion device designed to provide optimal embolization in several fields of the endovascular surgery. A full literature review was conducted to analyze AVPs in comparison with coils for the prevention of endoleaks during endovascular abdominal aortic aneurysm repair. Methods A systematic review was designed under PRISMA statement guidelines for systematic reviews and meta-analyses. The results were updated with a subsequent electronic search using Medline and Scopus databases up to December 2019. Results Eighteen articles making this comparison were found. In 79.7% of the cases, the target vessel was the internal iliac artery; in 1.6%, the common iliac artery; and in 16.7%, the inferior mesenteric artery. Risk of complications (buttock claudication, groin hematoma, endoleaks, and erectile dysfunction) after AVP was low. A cost comparison revealed that the mean cost for coils was around US$2262, while the average cost for the AVP was US$310. Conclusions The AVP is an effective and safe device for occluding peripheral vessels, proved to have lower complications rates. Compared with coil embolization, the AVP technique is potentially associated with lower procedural costs.


2021 ◽  
pp. 1-3
Author(s):  
Ahmet Vedat Kavurt ◽  
İbrahim Ece ◽  
Denizhan Bağrul

Abstract Acquired and congenital left ventricular to right atrial communication is rare, but nowadays, the frequency of the iatrogenic subgroup is increasing. Successful transcatheter closure of these defects with different devices has been reported. Herein, we presented successful closure of left ventricular to right atrial communication with Amplatzer Duct Occluder 2 after attempting to close with a failed Amplatzer Vascular Plug II device in a 7-year-old girl. This report supports that transcatheter closure of iatrogenic Gerbode defect with Amplatzer Duct Occluder 2 device is safe and effective.


2017 ◽  
Vol 7 (2) ◽  
pp. 63-72
Author(s):  
Michele Di Filippo ◽  
Danilo Barbarisi ◽  
Doriana Ferrara ◽  
Stefania Brancaccio ◽  
Luca del Guercio ◽  
...  

Objectives: Vascular occlusion of hemodialysis arteriovenous access (AVA) using an Amplatzer vascular plug (AVP; St. Jude Medical, St. Paul, MN, USA) is an arising and alternative practice in selected patients; however, few reported cases can be found in the literature. Herein, we report on our experience with endovascular treatment of complicated AVA. Materials and Methods: From September 2015 to December 2016, 3 patients at our clinic underwent an occlusion of hemodialysis AVA with 2 different Amplatzer vascular plugs: 2 patients with type II and 1 patient with type IV. Of these, 1 patient was treated for an autologous radiocephalic fistula, the second patient was treated for an autologous brachiocephalic fistula located at the elbow, and the third was, instead, treated for a radiocephalic forearm fistula. The reason for closing the AVA in all patients was due to the presence of dialysis-associated steal syndrome with critical hand ischemia and intractable ipsilateral edema. Results: All AVAs were treated using an AVP. No plug migration, access revascularization, persistent ischemia, nor other complications were observed. Conclusion: This report suggests that the use of AVP for embolization of complicated AVA is a safe and reasonable alternative to open surgery in selected patients.


2020 ◽  
Vol 30 (2) ◽  
pp. 243-248 ◽  
Author(s):  
Sneha M. Jain ◽  
Priya M. Pradhan ◽  
Supratim Sen ◽  
Bharat V. Dalvi

AbstractObjective:To evaluate the feasibility, efficacy, and safety of Amplatzer vascular plug II in large and elongated ducts in infants.Introduction:Patent arterial duct device closure is technically challenging in infants with large and elongated ducts because Amplatzer duct occluder and Amplatzer duct occluder II have high chances of causing aortic coarctation and left pulmonary artery stenosis, respectively. The Amplatzer vascular plug II being soft with no retention discs on either sides helps in mitigating these problems.Method:This is a prospective, observational study involving infants with clinical, echocardiographic and angiographic evidence of large left to right shunt. All the children underwent duct closure using Amplatzer vascular plug II.Results:Eighteen infants qualified for the study. Mean age and weight were 8.63 ± 3.84 months and 6.3 ± 1.7 kg, respectively. The angiographic mean duct diameter at the pulmonary artery end was 4.66 ± 0.92 mm, and the mean duct length was 9.4 ± 2.48 mm. The size of Amplatzer vascular plug II used varied from 6 mm to 10 mm. Technical success was achieved in 16/18 cases. One patient had device embolisation, and in the other, the device was found to be unstable. The ratio of Amplatzer vascular plug II size to the duct diameter was 1.65 ± 0.27, while the ratio of ductal length to device length was 1.48 ± 0.46 in those with successful outcome.Conclusions:Amplatzer vascular plug II is a safe and effective option in appropriately selected infants with elongated ducts. Diameter and length of Amplatzer vascular plug II vis-a-vis those of the ductus are important determinants of the successful outcome.


2015 ◽  
Vol 67 (5) ◽  
pp. 455-458 ◽  
Author(s):  
Gopalan Nair Rajesh ◽  
Kalathingathodika Sajeer ◽  
Anishkumar Nair ◽  
Vellani Haridasan ◽  
Chakanalil Govindan Sajeev ◽  
...  

2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Davide Castellano ◽  
Andrea Boghi ◽  
Chiara Comelli ◽  
Luca Di Maggio ◽  
Daniele Savio

Abstract Background We report the use of a 4 mm vascular Amplatzer for the occlusion of a renal arterovenous fistula between the renal artery, at the hylum trifurcation point, and an aneurismatic vein draining into the main renal vein, where there was no possibility to use any other device from the venous side, because of the diameter and the high flow, neither from the arterious side without sacrificing lobar branches. The device was implanted at the exact point of communication, like a patent foramen ovale occluder, with the distal disc into the artery lumen and the other two proximal discs into the venous side. Case presentation A 34-years-old Caucasian woman suffered several episodes of paroxysmal supraventricular tachycardia associated with dyspnoea, after the onset of post-pregnancy hypertension. She underwent CTA, spectral Doppler sonography and angiography which showed a renal arteriovenous fistula (RAVF) between the renal artery, at the hylum trifurcation point, and an extremely ectatic vein draining into the main renal vein of the right kidney. With both arterial and venous access, the RAVF was selectively embolized using a 4 × 6 mm Amplatzer Vascular Plug II, released into the communication between artery and vein ensuring the patency of vessels involved. The RAVF was almost completely excluded and the hemodynamic effects associated were also corrected. Conclusions The use of this device, though in an alternative way, allowed the exclusion of the high flow A-V fistula without sacrificing any parent renal vessel and preserving the renal function.


2016 ◽  
Vol 11 (13) ◽  
pp. 1537-1540 ◽  
Author(s):  
Maurizio Taramasso ◽  
Michel Zuber ◽  
Christiane Gruner ◽  
Oliver Gaemperli ◽  
Fabian Nietlispach ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document