Experimental and numerical evaluation on the geogrid cyclic and post-cyclic behavior by considering pre-cyclic pullout load effect

2021 ◽  
Vol 14 (6) ◽  
Author(s):  
Alireza Ardakani ◽  
Mahmoud Hassanlourad ◽  
Ali Namaei ◽  
Ali Mahigir
2018 ◽  
Vol 15 (1) ◽  
pp. 59
Author(s):  
NAZRUL AZMI AHMAD ZAMRI ◽  
CLOTILDA PETRUS ◽  
AZMI IBRAHIM ◽  
HANIZAH AB HAMID

The application of concrete filled steel tubes (CFSTs) as composite members has widely been used around the world and is becoming popular day by day for structural application especially in earthquake regions. This paper indicates that an experimental study was conducted to comprehend the behaviour of T-stub end plates connected to concrete filled thin-walled steel tube (CFTST) with different types of bolts and are subjected to pullout load. The bolts used are normal type bolt M20 grade 8.8 and Lindapter Hollo-bolt HB16 and HB20. A series of 10 mm thick T-stub end plates were fastened to 2 mm CFTST of 200 mm x 200 mm in cross-section. All of the specimens were subjected to monotonic pull-out load until failure. Based on test results, the Lidapter Hollo-bolts showed better performance compare to normal bolts. The highest ultimate limit load for T-stub end plate fasten with Lindapter Hollo-bolt is four times higher than with normal bolt although all end plates show similar behaviour and failure mode patterns. It can be concluded that T-stub end plate with Lindapter Hollo-bolt shows a better performance in the service limit and ultimate limit states according to the regulations in the design codes.


1990 ◽  
Author(s):  
P. SLEZIONA ◽  
MONIKA AUWETER-KURTZ ◽  
HERBERT SCHRADE

Author(s):  
Carlos Eduardo Ribeiro Santa Cruz Mendoza ◽  
Rafael Dunaiski ◽  
Edgar Ofuchi ◽  
Henrique Stel ◽  
Rigoberto Morales

2008 ◽  
Vol 17 (3) ◽  
pp. 474-475
Author(s):  
Yukihiro HARADA ◽  
Kazumasa EBATO ◽  
Junpei YAGI
Keyword(s):  

2000 ◽  
Vol 1696 (1) ◽  
pp. 144-149 ◽  
Author(s):  
Sami W. Tabsh ◽  
Muna Tabatabai

An important problem facing engineers and officials in the United States is the constraint imposed on transportation due to limitations of bridges. These limitations typically constrain vehicles to minimum heights and widths, to minimum and maximum lengths, and to a maximum allowable weight. However, with current demands of society and industry, there are times when a truck must carry a load that exceeds the size and weight of the legal limit. In this situation, the trucking company requests from the state departments of transportation an overload permit. For a truck with a wheel gauge larger than 1.8 m (6 ft), the process of issuing a permit for an overload truck requires a tremendous amount of engineering efforts. This is because the wheel load girder distribution factors (GDFs) in the design specifications cannot be used to estimate the live-load effect in the girders. In some cases, an expensive and time-consuming finite element analysis may be needed to check the safety of the structure. In this study, the finite element method is used to develop a modification factor for the GDF in AASHTO’s LRFD Bridge Design Specifications to account for oversized trucks with a wheel gauge larger than 1.8 m. To develop this factor, nine bridges were considered with various numbers of girders, span lengths, girder spacings, and deck slab thicknesses. The results indicated that use of the proposed modification factor with the GDF in the design specifications can help increase the allowable load on slab-on-girder bridges.


Sign in / Sign up

Export Citation Format

Share Document