Biomechanical analysis of a new bilateral pedicle screw fixator system based on topological optimization

2020 ◽  
Vol 21 (7) ◽  
pp. 1363-1374 ◽  
Author(s):  
Li-Xin Guo ◽  
Qing-Dong Wang
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Oujie Lai ◽  
Yunlin Chen ◽  
Qixin Chen ◽  
Yong Hu ◽  
Weihu Ma

Abstract Background This study was to evaluate and compare the biomechanical features of multilevel lateral lumbar interbody fusion (LLIF) with or without supplemental instrumentations. Methods Six human lumbar specimens were tested under multidirectional nondestructive moments (7.5 N·m), with a 6 degree-of-freedom spine simulator. The overall and intervertebral range of motion (ROM) were measured optoelectronically. Each specimen was tested under the following conditions at L2–5 levels: intact; stand-alone; cage supplemented with lateral plate (LP); cage supplemented with unilateral or bilateral pedicle screw/rod (UPS or BPS). Results Compared with intact condition, the overall and intersegmental ROM were significantly reduced after multilevel stand-alone LLIF. The ROM was further reduced after using LP instrumentation. In flexion-extension (FE) and axial rotation (AR), pedicle screw/rod demonstrated greater overall ROM reduction compared to LP (P < 0.01), and bilateral greater than unilateral (P < 0.01). In lateral bending (LB), BPS demonstrated greater overall ROM reduction compared to UPS and LP (P < 0.01), however, UPS and LP showed similar reduction (P = 0.245). Intervertebral ROM reductions showed similar trend as the overall ones after using different types of instrumentation. However, at L2/3 (P = 0.57) and L3/4 (P = 0.097) levels, the intervertebral ROM reductions in AR were similar between UPS and LP. Conclusions The overall and intervertebral stability increased significantly after multilevel LLIF with or without supplemental instrumentation. BPS provided the greatest stability, followed by UPS and LP. However, in clinical practice, less invasive adjunctive fixation methods including UPS and LP may provide sufficient biomechanical stability for multilevel LLIF.


2010 ◽  
Vol 12 (6) ◽  
pp. 700-708 ◽  
Author(s):  
Hong Bo Sim ◽  
Judith A. Murovic ◽  
Bo Young Cho ◽  
T. Jesse Lim ◽  
Jon Park

Object Both posterior lumbar interbody fusion (PLIF) and transforaminal lumbar interbody fusion (TLIF) have been frequently undertaken for lumbar arthrodesis. These procedures use different approaches and cage designs, each of which could affect spine stability, even after the addition of posterior pedicle screw fixation. The objectives of this biomechanical study were to compare PLIF and TLIF, each accompanied by bilateral pedicle screw fixation, with regard to the stability of the fused and adjacent segments. Methods Fourteen human L2–S2 cadaveric spine specimens were tested for 6 different modes of motion: flexion, extension, right and left lateral bending, and right and left axial rotation using a load control protocol (LCP). The LCP for each mode of motion utilized moments up to 8.0 Nm at a rate of 0.5 Nm/second with the application of a constant compression follower preload of 400 N. All 14 specimens were tested in the intact state. The specimens were then divided equally into PLIF and TLIF conditions. In the PLIF Group, a bilateral L4–5 partial facetectomy was followed by discectomy and a single-level fusion procedure. In the TLIF Group, a unilateral L4–5 complete facetectomy was performed (and followed by the discectomy and single-level fusion procedure). In the TLIF Group, the implants were initially positioned inside the disc space posteriorly (TLIF-P) and the specimens were tested; the implants were then positioned anteriorly (TLIF-A) and the specimens were retested. All specimens were evaluated at the reconstructed and adjacent segments for range of motion (ROM) and at the adjacent segments for intradiscal pressure (IDP), and laminar strain. Results At the reconstructed segment, both the PLIF and the TLIF specimens had significantly lower ROMs compared with those for the intact state (p < 0.05). For lateral bending, the PLIF resulted in a marked decrease in ROM that was statistically significantly greater than that found after TLIF (p < 0.05). In flexion-extension and rotation, the PLIF Group also had less ROM, however, unlike the difference in lateral bending ROM, these differences in ROM values were not statistically significant. Variations in the position of the implants within the disc space were not associated with any significant differences in ROM values (p = 0.43). Analyses of ROM at the adjacent levels L2–3, L3–4, and L5–S1 showed that ROM was increased to some degree in all directions. When compared with that of intact specimens, the ROMs were increased to a statistically significant degree at all adjacent segments in flexion-extension loads (p < 0.05); however, the differences in values among the various operative procedures were not statistically significant. The IDP and facet contact force for the adjacent L3–4 and L5–S1 levels were also increased, but these values were not statistically significantly increased from those for the intact spine (p > 0.05). Conclusions Regarding stability, PLIF provides a higher immediate stability compared with that of TLIF, especially in lateral bending. Based on our findings, however, PLIF and TLIF, each with posterolateral fusions, have similar biomechanical properties regarding ROM, IDP, and laminar strain at the adjacent segments.


Sign in / Sign up

Export Citation Format

Share Document