Heat flow measurements in the southern portion of the Gulf of California

1973 ◽  
Vol 19 (2) ◽  
pp. 198-208 ◽  
Author(s):  
Lawrence A. Lawver ◽  
John G. Sclater ◽  
Thomas L. Henyey ◽  
J. Rogers
2017 ◽  
Vol 479 ◽  
pp. 340-353 ◽  
Author(s):  
Florian Neumann ◽  
Raquel Negrete-Aranda ◽  
Robert N. Harris ◽  
Juan Contreras ◽  
John G. Sclater ◽  
...  

2021 ◽  
Author(s):  
Raquel Negrete-Aranda ◽  
Florian Neumann ◽  
Juan Contreras ◽  
Robert N. Harris ◽  
Ronald M. Spelz ◽  
...  

<p>New heat flow measurements collected throughout the Auka and JaichMaa Ja' ag' hydrothermal vent fields in the central graben of the Southern Pescadero Basin, southern Gulf of California, indicate that upflow of hydrothermal fluids associated with active rifting dissipate heat in excess of 10 W/m<sup>2</sup> around faults that have a few tens-of-meters of displacement. Heat flow anomalies slowly decay to background values of ~2 W/m<sup>2</sup> at distances of ~1 km from these faults following an inverse square-root distance law. We develop a physical model of the Auka vent field based on the fundamental Green's function solution of the heat equation. The model includes the effects of circulation in the porous networks of faults and the lateral seepage of geothermal brines through the fault walls to surrounding hemipelagic sediments.  We use an optimal fitting method to estimate the reservoir depth, permeability, and circulation rate. Our model indicates the heat source is at a depth of ~5.7 km; permeability and flow rates in the fracture system are ~10<sup>-14</sup> m<sup>2</sup> and 10<sup>-7</sup> m/s, respectively, and ~10<sup>-16</sup> m<sup>2</sup> and 10<sup>-8</sup> m/s in the basin aquitards, respectively. Model scaling laws point to the importance of faults in controlling sediment-hosted vent fields and slow circulation throughout low permeability sediments in controlling the brine's chemistry. Although the fault model seems appropriate and straightforward for the Pescadero vents, it does seem to be the exception to the other known sediment-hosted vent fields in the Pacific.</p>


2010 ◽  
Vol 47 (4) ◽  
pp. 389-408 ◽  
Author(s):  
Claire Perry ◽  
Carmen Rosieanu ◽  
Jean-Claude Mareschal ◽  
Claude Jaupart

Geothermal studies were conducted within the framework of Lithoprobe to systematically document variations of heat flow and surface heat production in the major geological provinces of the Canadian Shield. One of the main conclusions is that in the Shield the variations in surface heat flow are dominated by the crustal heat generation. Horizontal variations in mantle heat flow are too small to be resolved by heat flow measurements. Different methods constrain the mantle heat flow to be in the range of 12–18 mW·m–2. Most of the heat flow anomalies (high and low) are due to variations in crustal composition and structure. The vertical distribution of radioelements is characterized by a differentiation index (DI) that measures the ratio of the surface to the average crustal heat generation in a province. Determination of mantle temperatures requires the knowledge of both the surface heat flow and DI. Mantle temperatures increase with an increase in surface heat flow but decrease with an increase in DI. Stabilization of the crust is achieved by crustal differentiation that results in decreasing temperatures in the lower crust. Present mantle temperatures inferred from xenolith studies and variations in mantle seismic P-wave velocity (Pn) from seismic refraction surveys are consistent with geotherms calculated from heat flow. These results emphasize that deep lithospheric temperatures do not always increase with an increase in the surface heat flow. The dense data coverage that has been achieved in the Canadian Shield allows some discrimination between temperature and composition effects on seismic velocities in the lithospheric mantle.


Terra Nova ◽  
2021 ◽  
Author(s):  
Rosa Maria Prol‐Ledesma ◽  
Juan Luis Carrillo De La Cruz ◽  
Marco‐Antonio Torres‐Vera ◽  
Alejandro Estradas‐Romero

1976 ◽  
Vol 29 (2) ◽  
pp. 243-254 ◽  
Author(s):  
Roger N. Anderson ◽  
Marcus G. Langseth ◽  
Victor Vacquier ◽  
Jean Francheteau

1987 ◽  
Vol 24 (7) ◽  
pp. 1486-1489 ◽  
Author(s):  
Malcolm Drury ◽  
Alan Taylor

Borehole heat-flow measurements are reported from six new sites in the Superior Province of the Canadian Shield. Values adjusted for glaciation effects, but not for Holocene climatic variations, range from 42 to 56 mW/m2. When these new values are combined with 21 previously published borehole values the mean is 42 mW/m2 with a standard deviation of 11 mW/m2. The data for a site on the Lac du Bonnet batholith suggest that the batholith has a thin veneer, less than 3 km, of rock of high radiogenic heat production at the surface.


2016 ◽  
Vol 87 (2) ◽  
pp. 165-174
Author(s):  
Elena Onofrei ◽  
Teodor-Cezar Codau ◽  
Gauthier Bedek ◽  
Daniel Dupont ◽  
Cedric Cochrane

This paper describes the concept of creating and testing of a textile heat flow sensor in order to determine the amount of heat exchanged between the human body and its environment. The main advantage of this sensor is the permeability to moisture, which allows taking into account the evaporation phenomenon, contrary to the traditional heat flow sensors. Another property related to this new sensor is its flexibility conferred by the textile substrate, which allows it to be applied on deformable surfaces.


Sign in / Sign up

Export Citation Format

Share Document