Non injecting back-contacts in surface barrier silicon detectors

1967 ◽  
Vol 53 ◽  
pp. 337-338 ◽  
Author(s):  
G. Fabri ◽  
M. Nasini ◽  
G. Redaelli
1965 ◽  
Vol 19 (5) ◽  
pp. 1414-1415 ◽  
Author(s):  
G. F. Bogdanov ◽  
B. P. Maksimenko

1969 ◽  
Vol 26 (3) ◽  
pp. 280-283
Author(s):  
G. F. Bogdanov ◽  
B. P. Maksimenko

1982 ◽  
Vol 16 ◽  
Author(s):  
S. Ohkawa ◽  
K. Husimi ◽  
C. Kim ◽  
Y. Kim ◽  
D. Itoh

ABSTRACTA remarkable characteristic of the surface barrier detector with a side groove cooled down to the nitrogen temperature has been observed. That is an abrupt decrease of the output noise at a definite voltage in increasing the bias voltage slowly. This is caused by a carrier injection from the side surface of the groove near the neck narrowed by the side groove. This excess noise disappears after the depletion layer goes through the neck of the side groove. This is confirmed by the fact that the capacitance of the detector decreases abruptly with the decrease of the noise at the same bias voltage. This detector is capable to be operated at a voltage higher than this voltage with a low noise. The maximum bias voltage applied to the detector is 3000 V.


1985 ◽  
Vol 32 (1) ◽  
pp. 476-481 ◽  
Author(s):  
Y. Kim ◽  
C. Kim ◽  
S. Ohkawa ◽  
K. Husimi ◽  
T. Sakai ◽  
...  

Author(s):  
G. Apollinari ◽  
S. Belforte ◽  
F. Bosi ◽  
E. Focardi ◽  
R. Paoletti ◽  
...  

1989 ◽  
Vol 36 (1) ◽  
pp. 46-53 ◽  
Author(s):  
G. Apollinari ◽  
S. Belforte ◽  
E. Focardi ◽  
R. Paoletti ◽  
G. Tonelli ◽  
...  

2021 ◽  
Vol 2103 (1) ◽  
pp. 012138
Author(s):  
S V Bakhlanov ◽  
A V Derbin ◽  
I S Drachnev ◽  
O I Konkov ◽  
I M Kotina ◽  
...  

Abstract The response function of the recoil nuclei in detectors designed for detection of neutrinos or dark matter particles can be determined only through usage of a neutron source with a known energy spectrum. A possible solution for a compact neutron calibration source is a combination of a 252Cf neutron source and a semiconductor detector that detects fission fragments, and thus records the neutron emission moment. This work is devoted to the degradation study of the operating parameters for silicon semiconductor detectors irradiated by fission fragments of the nuclide of 252 Cf. Two types of Si detectors were under investigations - silicon-lithium Si(Li) p-i-n detectors and silicon surface barrier detectors. As a result of the measurements, the maximum permissible radiation doses for the correct operation of both types of detectors and the relation of the received radiation dose to the spectroscopic characteristics of the detectors were determined.


Sign in / Sign up

Export Citation Format

Share Document