Construction and performance of a slow positron beam guided by an increasing magnetic field

1995 ◽  
Vol 85 ◽  
pp. 138-142
Author(s):  
Y. Shirai ◽  
H. Miura ◽  
M. Yamaguchi
1997 ◽  
Vol 255-257 ◽  
pp. 677-679 ◽  
Author(s):  
Yoshihide Honda ◽  
Masaki Maekawa ◽  
N. Kimura ◽  
T. Kozawa ◽  
S. Nishijima ◽  
...  

2014 ◽  
Vol 70 (a1) ◽  
pp. C1613-C1613
Author(s):  
Ken Wada ◽  
Masaki Maekawa ◽  
Yuki Fukaya ◽  
Izumi Mochizuki ◽  
Toshio Hyodo ◽  
...  

A high-intensity mono-energetic positron beam generated by using a linear electron accelerator (linac) provides total reflection high-energy positron diffraction (TRHEPD) researches at Slow Positron Facility (SPF), KEK [1,2]. A pulsed 50-Hz electron beam generated with a dedicated linac (operated at 55 MeV, 0.6 kW) is injected on a Ta converter and causes fast positron-electron pair creation through bremsstrahlung. The positrons showering down on 25 μm-thick W foils, are moderated to thermal energy, and a fraction spontaneously comes out of the foils with an energy of 3 eV owing to the negative work function. The positron converter/moderator assembly is held at an electrostatic voltage of 15 kV for TRHEPD experiment. The emitted positrons are consequently accelerated to 15 keV as they enter the grounded beam-line and are guided by the magnetic field of about 0.015 T to the TRHEPD station. For diffraction experiments, positrons transported by the magnetic field have to be first released into a nonmagnetic region. Since the released positron beam has a large diameter, a brightness-enhancement unit is effectively used to achieve a small-diameter and highly-parallel beam with a sufficient flux. The linac-based positron beam gives about 60 times intensified diffraction pattern from a Si(111)-7x7 reconstructed surface compared to a previous result with a Na-22-based positron beam [3]. An improved signal-to-noise ratio in the obtained pattern due to the intensified beam allowed an observation of clear fractional-order spots in the higher Laue-zones, which had not been observed previously. The much intensified beam with the present system allows adjustment of the sample orientation without accumulating the positron signals. With the brightness enhanced beam, several remarkable results have been obtained efficiently by users of this facility. (Everybody is invited to use KEK Slow Positron Facility through approval of his/her research proposal.)


2021 ◽  
Vol 7 (3) ◽  
pp. 17-24
Author(s):  
Thanh Long Cao ◽  
Trung Hieu Nguyen ◽  
Quoc Dung Tran ◽  
Dong Phuong Huynh

Slow Positron Beam (PB) is an important device in the study of positron physics andtechniques, especially in material research. For the purpose of conceptual designing a PB system, we have simulated a PB system with the parameters of an existing system – SPONSOR, using SIMION software. The simulation results have been compared with the SPONSOR published results. The effect of magnetic field in controlling beam trajectory has been investigated in the preaccelerated and accelerated stages. The simulation results of using steering coils to adjust the beam trajectory are also presented in this report.


1999 ◽  
Vol 149 (1-4) ◽  
pp. 175-180 ◽  
Author(s):  
J.W. Taylor ◽  
A.S. Saleh ◽  
P.C. Rice-Evans ◽  
A.P. Knights ◽  
C. Jeynes

2004 ◽  
Vol 37 (13) ◽  
pp. 1841-1844 ◽  
Author(s):  
S W Jin ◽  
X Y Zhou ◽  
W B Wu ◽  
C F Zhu ◽  
H M Weng ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document