Upper Extremity Salvage with Free Flaps in High Voltage Electrical Injuries

1994 ◽  
Vol 19 (1_suppl) ◽  
pp. 6-6
Author(s):  
M. Topalan ◽  
N. Çerkeş ◽  
M. Erer
Hand Surgery ◽  
2005 ◽  
Vol 10 (02n03) ◽  
pp. 177-185 ◽  
Author(s):  
M. Akinci ◽  
Ş Ay ◽  
S. Kamiloglu ◽  
Ö. Erçetin

Lateral arm flaps are versatile in the use of upper extremity moderate-sized defects with little morbidity and with acceptable cosmesis. The conditions are outlined in a series of 74 lateral arm flaps performed on 72 patients and the results are given. Five patients were operated on as emergencies, 12 were operated within the first 72 hours of injury and 57 patients were treated electively. Skin defects were between 6 × 4 cm and 20 × 9 cm . Five (7%) flaps were lost due to venous thrombosis, three that sustained a high-voltage electric burn. Two other patients that were treated for a high-voltage electric burn had a successful revision of the anastomosis site in the early post-operative duration. One flap was abandoned due to very thin pedicle and obesity of the patient. A higher failure rate is encountered most frequently with the cases of high-voltage electric burn. To deal with this problem, a modified approach such as an extended approach and/or including the forearm skin to the flap is recommended during the flap harvest. For a longer pedicle to be anatomized more proximally, perforator flaps with longer pedicles may be used as an alternative.


2020 ◽  
Vol 41 (Supplement_1) ◽  
pp. S266-S267
Author(s):  
Matthew A Depamphilis ◽  
Ryan Cauley ◽  
Farzin Sadeq ◽  
Robert Sheridan ◽  
Daniel N Driscoll

Abstract Introduction High voltage electrical burns are often associated with significant morbidity, posing great acute and delayed reconstructive challenges for plastic surgeons. As survival from these injuries increases, attention has been focused on improving quality of life post burn injury through restoration of sensory and motor function. However, due to the complexity of the upper extremity and its small surface area in pediatric patients, its reconstruction can be a very complex endeavor. Especially in pediatric patients that are still growing, ensuing great risk for upper extremity contracture and deformity. Methods A retrospective chart review was conducted on patients aged 0–18 years admitted to our institution with a high voltage electrical burn involving the upper extremity. The timeframe under study was 13 years from January 1st 2005 to December 1st 2018. This project was undertaken at our institution as an exempt project under 45 CFR 46.101 and, as such, it was not formally supervised by an Institutional Review Board. Results Out of the 68 electrical burns treated at our pediatric burn center, 58 involved the upper extremity. This further divides into 37 patients with high voltage and 31 patients with low voltage upper extremity electric burns. Of the 37 high voltage upper extremity patients, 35 underwent acute surgical management and 18 had delayed surgical reconstruction for the upper extremity. Conclusions The reconstructive techniques employed at our institution following severe electrical injuries typically follow a reconstructive ladder. The majority of chronic contractures in our series were successfully treated with either minimally invasive techniques such as laser and steroid infiltration, local tissue flaps, or release and skin grafting. Applicability of Research to Practice Multidisciplinary treatment of severe electrical injuries to the upper extremity is vital to optimizing a patient’s long-term function. Given the significant depth of injury in cases of electrical burns to the upper extremity the risk of developing contractures is relatively high. The expeditious treatment of secondary contractures is important to maximize a patient’s long-term function. The general treatment of contractures of the upper extremity should be based on the location and severity of the contracture, with considerations made for the patient’s reconstructive goals.


2010 ◽  
Vol 31 (4) ◽  
pp. 670-673 ◽  
Author(s):  
Grant Fankhauser ◽  
Aaron Klomp ◽  
Anthony Smith ◽  
Alanna Rececca ◽  
William Casey

2020 ◽  
Vol 41 (4) ◽  
pp. 788-790
Author(s):  
Harold Campbell ◽  
Rabia Nizamani ◽  
Samuel W Jones ◽  
Felicia N Williams

Abstract The art of pyrography, burning designs in wood, dates back to prehistory. Risks of traditional techniques included cutaneous burns and airway injury. Fractal wood burning is a niche technique using a high-voltage electrical source to burn branched designs into wood. While this technique has grown in popularity, the associated risks are not well understood. We describe a patient who presented to our burn center after sustaining high-voltage electrical injuries while making fractal wood art using an improvised a high-voltage transformer. During the wood-burning process, he contacted the electrodes and suffered full-thickness electrical burns to the neck, chest, and bilateral upper extremities. Bilateral upper extremity fasciotomies were performed on admission. Multiple subsequent operations culminated with autografting to most of the wounds and complex reconstruction of the left thumb. In evaluating online news reports, we found 25 unique individuals with death or injury attributed to fractal wood burning from July 2016 to January 2020. Five sustained substantial injuries, while 20 reportedly died. Ages ranged from 17 years old to the 60s. One death and one injury occurred in females, with the remainder of reports involving males. Of the survivors, four sustained significant upper extremity electrical injuries and three suffered cardiac arrest at the time of injury. Fractal wood burning is associated with devastating high-voltage electrical injuries and death. Prevention efforts should be focused on education about the potential for death and permanently disabling injuries from this art form.


2021 ◽  
Vol 42 (Supplement_1) ◽  
pp. S130-S131
Author(s):  
Andrew Khalifa ◽  
Anzar Sarfraz ◽  
Jacob B Avraham ◽  
Ronnie Archie ◽  
Matthew Kaminsky ◽  
...  

Abstract Introduction Electrical injuries represent 0.4–3.2% of admissions to burn units and are responsible for >500 deaths per year in the United States. Approximately half occur in the workplace and are the fourth leading cause of work-related-traumatic death. The extent of injury can be drastically underestimated by total body surface area percentage (TBSA). Along with cutaneous burns, high voltage electrical injuries can lead to necrosis of muscle, bone, nervous tissue, and blood vessels. Aggressive management allows for patient survival, but at significant cost. Newer technologic advances help improve functional outcomes. Methods This case-report was conducted via retrospective chart review of the case presented. Results A 43-year-old male sustained a HVEI (>10, 000 V) after contacting an active wire while working as a linesman for an electric company. He presented after less than 15-minute transport from an outside hospital with full thickness burns and auto-amputation to all fingers on both hands and the distal third of the left hand (Images 1 and 2). There were full thickness circumferential burns to the entire left and right upper extremities with contractures, with the burns extending into the axilla, and chest wall musculature. The patient had 4th degree burns and a large wound to the left shoulder with posterior extension to the scapula, flank and back with approximately 25% TBSA (Image 3). Compartments were tense in both upper extremities. Patient was sedated and intubated to protect the airway and placed on mechanical ventilation. A femoral central line was then placed, and the patient was given pain control, continued fluid resuscitation, and blood products. Dark red colored urine from a foley catheter that was immediately identified as rhabdomyolysis induced myoglobinuria. Labs drawn demonstrated elevated troponin I, CK >40,000. BUN 18, creatinine 1.0, K+ 5.2 and phosphate 5.6. Decision was made immediately for operative intervention with emergent amputation of both upper extremities in the light of rhabdomyolysis secondary to tissue necrosis and oliguria. During the patient’s hospital course, he underwent multiple operations for further debridement with vacuum-assisted closure therapy and skin grafting of sites, as well as targeted muscle reinnervation (TMR) 6 months later at an outside hospital. Conclusions Although HVEI only account for a small percentage of burn admissions, they are associated with greater morbidity than low-voltage injuries. Patients with HVEI often incur multiple injuries, more surgical procedures, have higher rates of complications, and more long term psychological and rehabilitative difficulties. Despite the need for amputation in some of these critically ill patients, options exist that allow for them to obtain long term functional success.


2019 ◽  
Vol 7 (12) ◽  
pp. e2543
Author(s):  
Christoph Koepple ◽  
Ann-Katrin Kallenberger ◽  
Lukas Pollmann ◽  
Gabriel Hundeshagen ◽  
Volker J. Schmidt ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document