Relationship between ethanol consumption rate and prochiral ketone reduction rate in bakers' yeast

1995 ◽  
Vol 80 (2) ◽  
pp. 208-210 ◽  
Author(s):  
Tadashi Kometani ◽  
Yasufumi Morita ◽  
Yoshiharu Kiyama ◽  
Hidefumi Yoshii ◽  
Ryuichi Matsuno
2009 ◽  
Vol 20 (10) ◽  
pp. 1150-1153 ◽  
Author(s):  
Umesh Balakrishnan ◽  
Nallamuthu Ananthi ◽  
Sivan Velmathi

Energies ◽  
2019 ◽  
Vol 12 (6) ◽  
pp. 1002 ◽  
Author(s):  
Chung-Yao Hsuan ◽  
Shuhn-Shyurng Hou ◽  
Yun-Li Wang ◽  
Ta-Hui Lin

An experimental system for observing the drop vaporization and microexplosion characteristics of emulsified droplets in high-temperature environments was conducted to analyze the effects of environmental temperature, droplet size, and water content on droplet behavior. In addition, emulsified low-sulfur heavy fuel oil (HFO) with a 20 vol% water content and pure low-sulfur HFO were used as fuels for burning in an industrial boiler under normal operating conditions. The results showed that by using an emulsified HFO with a 20 vol% water content, the boiler efficiency can be improved by 2%, and that a reduction of 35 ppm in NOx emissions (corresponding to a NOx reduction rate of 18%) can be achieved. These advantages are due to the occurrence of a microexplosion during the combustion of the emulsified droplets. It was observed that when emulsified HFO with a 20 vol% water content was used, the fuel (HFO) consumption rate was 252 l/h. On the other hand, the fuel consumption rate was 271 l/h when pure low-sulfur HFO was used. Therefore, a reduction of 19 l/h in the fuel (HFO) consumption rate was achieved when using the water-in-oil emulsion, corresponding to fuel savings of 7%.


2020 ◽  
Vol 14 (3) ◽  
pp. 7109-7124
Author(s):  
Nasreddine Sakhri ◽  
Younes Menni ◽  
Houari Ameur ◽  
Ali J. Chamkha ◽  
Noureddine Kaid ◽  
...  

The wind catcher or wind tower is a natural ventilation technique that has been employed in the Middle East region and still until nowadays. The present paper aims to study the effect of the one-sided position of a wind catcher device against the ventilated space or building geometry and its natural ventilation performance. Four models based on the traditional design of a one-sided wind catcher are studied and compared. The study is achieved under the climatic conditions of the South-west of Algeria (arid region). The obtained results showed that the front and Takhtabush’s models were able to create the maximum pressure difference (ΔP) between the windward and leeward of the tower-house system. Internal airflow velocities increased with the increase of wind speed in all studied models. For example, at Vwind = 2 m/s, the internal flow velocities were 1.7, 1.8, 1.3, and 2.5 m/s for model 1, 2, 3, and 4, respectively. However, at Vwind = 6 m/s, the internal flow velocities were 5.6, 5.5, 2.5, and 7 m/s for model 1, 2, 3, and 4, respectively. The higher internal airflow velocities are given by Takhtabush, traditional, front and middle tower models, respectively, with a reduction rate between the tower outlet and occupied space by 72, 42, 36, and 33% for the middle tower, Takhtabush, traditional tower, and the front model tower, respectively. This reduction is due to the due to internal flow resistance. The third part of the study investigates the effect of window (exist opening) position on the opposite wall. The upper, middle and lower window positions are studied and compared. The air stagnation or recirculation zone inside the ventilated space reduced from 55% with the lower window to 46% for the middle window and reached 35% for the upper window position. The Front and Takhtabush models for the one-sided wind catcher with an upper window position are highly recommended for the wind-driven natural ventilation in residential houses that are located in arid regions.


1973 ◽  
Vol 34 (2) ◽  
pp. 520-524 ◽  
Author(s):  
Kathy Kazmaier ◽  
Richard E. Butcher ◽  
R. J. Senter ◽  
Robert M. Stutz

1965 ◽  
Vol 48 (2) ◽  
pp. 263-271 ◽  
Author(s):  
Herbert Schriefers ◽  
Gerlinde Scharlau ◽  
Franzis Pohl

ABSTRACT After the administration of anabolic steroids to adult female rats in daily doses of 1 mg per animal for 14 days, the following parameters were investigated: the rate of the Δ4-5α-hydrogenase-catalyzed cortisone reduction in liver slices and microsomal fractions, the adrenal weight and the in vitro corticosterone production rate. Among the steroids tested, only 17α-methyl-testosterone and 17α-ethyl-19-nor-testosterone were effective in lowering significantly cortisone reduction rate by liver slices with concomitant decreases in microsomal Δ4-5α-hydrogenase-activity. Testosterone, 19-nor-testosterone, 17α-ethinyl-19-nor-testosterone, 17α-methyl-17β-hydroxy-androsta-1,4-dien-3-one and 1-methyl-17β-hydroxy-androst-1-en-3-one were ineffective or only slightly effective. Adrenal weight and absolute corticosterone production rate (μg/60 min per animal) were decreased after treatment with 17α-methyl-testosterone, 17α-ethyl-19-nor-testosterone and 1-methyl-17β-hydroxy-androst-1-en-3-one. Corticosterone production was decreased with 17α-ethinyl-19-nor-testosterone in spite of an unchanged adrenal weight. The relative corticosterone production rate (μg/60 min · 100 mg adrenal) was in any cases unaffected. According to these results there exists – with the exception of 17α-ethinyl-19-nor-testosterone – a strict parallelism between corticosteroid turnover and corticosterone production rate: unchanged turnover is correlated with unchanged corticosterone production rate, while a decreased turnover is correlated with decreased adrenal activity. The protein-anabolic effect of certain anabolic steroids may be partly due to an anti-catabolic action of these compounds resulting from a decreased corticosteroid inactivation and production rate. Possible mechanisms by which anabolic steroids may affect corticosteroid-balance are discussed.


Sign in / Sign up

Export Citation Format

Share Document