Endovascular Treatment of Intracranial Aneurysms

Stroke ◽  
2022 ◽  
pp. 985-1000.e4
Author(s):  
Miklos Marosfoi ◽  
Emanuele Orrù ◽  
Margarita Rabinovich ◽  
Sarah Newman ◽  
Neil V. Patel ◽  
...  
Neurosurgery ◽  
2017 ◽  
Vol 64 (CN_suppl_1) ◽  
pp. 228-228
Author(s):  
Erick Michael Westbroek ◽  
Matthew Bender ◽  
Narlin B Beaty ◽  
Bowen Jiang ◽  
Risheng Xu AB ◽  
...  

Abstract INTRODUCTION ISAT demonstrated that coiling is effective for aneurysm treatment in subarachnoid hemorrhage (SAH); however, complete occlusion of wide-necked aneurysms frequently requires adjuvants relatively contraindicated in SAH. As such, a limited “dome occlusive” strategy is often pursued in the setting of SAH. We report a single institution series of coiling of acutely ruptured aneurysms followed by delayed flow diversion for definitive, curative occlusion. METHODS A prospectively collected IRB-approved database was screened for patients with aneurysmal SAH who were initially treated by coil embolization followed by planned flow diversion at a single academic medical institution. Peri-procedural outcomes, complications, and angiographic follow-up were analyzed. RESULTS >50 patients underwent both acute coiling followed by delayed, planned flow diversion. Average aneurysm size on initial presentation was 9.5 mm. Common aneurysm locations included Pcomm (36%), Acomm (30%), MCA (10%), ACA (10%), and vertebral (5%). Dome occlusion was achieved in all cases following initial coiling. Second-stage implantation of a flow diverting stent was achieved in 49/50 cases (98%). Follow-up angiography was available for 33/50 patients (66%), with mean follow-up of 11 months. 27 patients (82%) had complete angiographic occlusion at last follow up. All patients with residual filling at follow-up still had dome occlusion. There were no mortalities (0%). Major complication rate for stage I coiling was 2% (1 patient with intra-procedural aneurysm re-rupture causing increase in a previous ICH). Major complication rate for stage 2 flow diversion was 2% (1 patient with ischemic stroke following noncompliance with dual antiplatelet regimen). Minor complications occurred in 2 additional patients (4%) with transient neurological deficits. CONCLUSION Staged endovascular treatment of ruptured intracranial aneurysms with acute dome-occlusive coil embolization followed by delayed flow diversion is a safe and effective treatment strategy.


2008 ◽  
Vol 108 (6) ◽  
pp. 1230-1240 ◽  
Author(s):  
Thomas R. Marotta ◽  
Thorsteinn Gunnarsson ◽  
Ian Penn ◽  
Donald R. Ricci ◽  
Ian Mcdougall ◽  
...  

Object The authors describe a novel device for the endovascular treatment of intracranial aneurysms, the endovascular clip system (eCLIPs). Descriptions of the device and its delivery system as well as the results of flow model tests and the treatment of experimental aneurysms are provided. Methods The eCLIPs comprises a flexible hybrid implantable device (an anchor and a covered leaf) and a balloon catheter delivery system, designed to be positioned and activated in the parent vessel in such a way that the covered portion will abut the aneurysm neck. The eCLIPs was subjected to testing in glass, elastomeric, and cadaveric flow models to determine its navigability, orientation, and activation compared with commercially available stents. In a second experiment, 8 carotid artery sidewall aneurysms in swine were treated using eCLIPs. The degree of occlusion was observed on angiography immediately following and 30 days after device activation, and a histological analysis was performed at 30 days. Results The device could navigate tortuous glass models and human cadaveric vessels. Compared with commercially available stents, the eCLIPs performed well. It could be navigated, oriented, and activated easily and reliably. With regard to the 8 porcine experimental aneurysms, immediate postactivation angiograms confirmed complete occlusion of 4 lesions and near occlusion of the other 4. Angiographic follow-up at 30 days postactivation showed occlusion of all 8 aneurysms and patency of all parent vessels. Histopathological analysis revealed aneurysm healing, with smooth-muscle cells growing across the lesion neck to allow reendothelialization. Conclusions Aneurysm occlusion with a single extrasaccular endovascular device has potential advantages. The authors believe that eCLIPs may prove to be a useful tool in the endovascular treatment of cerebral aneurysms. The system should reduce risks associated with coiling, procedure time, costs, and radiation exposure. The device satisfactorily occluded 8 experimental sidewall aneurysms. The observed healing pattern is similar to that seen after microsurgical clipping.


2010 ◽  
Vol 16 (3) ◽  
pp. 231-239 ◽  
Author(s):  
L.M. Pyysalo ◽  
L.H. Keski-Nisula ◽  
T.T. Niskakangas ◽  
V.J. Kähärä ◽  
J.E. Öhman

Long-term follow-up studies after endovascular treatment for intracranial aneurysm are still rare and inconclusive. The aim of this study was to assess the long-term clinical and angiographic outcome of patients with endovascularly treated aneurysms. The clinical outcome of all 185 patients with endovascularly treated aneurysms were analyzed and 77 out of 122 surviving patients were examined with MRI and MRA nine to 16 years (mean 11 years) after the initial endovascular treatment. Sixty-three patients were deceased at the time of follow-up. The cause of death was aneurysm-related in 34 (54%) patients. The annual rebleeding rate from the treated aneurysms was 1.3% in the ruptured group and 0.1% in the unruptured group. In long-term follow-up MRA 18 aneurysms (53%) were graded as complete, 11 aneurysms (32%) had neck remnants and five aneurysms (15%) were incompletely occluded in the ruptured group. The occlusion grade was lower in the unruptured group with 20 aneurysms (41%) graded as complete, 11 (22%) had neck remnants and 18 (37%) were incomplete. However, only three aneurysms were unstable during the follow-up period and needed retreatment. Endovascular treatment of unruptured aneurysms showed incomplete angiographic outcome in 37% of cases. However, the annual bleeding rate was as low as 0.1%. Endovascular treatment of ruptured aneurysms showed incomplete angiographic outcome in 15% of cases and the annual rebleeding rate was 1,3%.


Sign in / Sign up

Export Citation Format

Share Document