scholarly journals 21: Robotic myomectomy- an 18 cm broad ligament fibroid

2017 ◽  
Vol 216 (3) ◽  
pp. S625
Author(s):  
O.S. Madueke Laveaux ◽  
M. Pitter
2016 ◽  
Vol 21 (1) ◽  
pp. 65-68
Author(s):  
Ahmed Abdelaziz ◽  
Salem Joseph ◽  
Mostafa Abuzeid

2021 ◽  
Vol 28 (11) ◽  
pp. S25-S26
Author(s):  
T.E. Ito ◽  
L.A. Haworth ◽  
J. Jones ◽  
J.L. Hudgens

2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Yoshifumi Hashimoto ◽  
Tatsuo Kanda ◽  
Tadasu Chida ◽  
Kazuyoshi Suda

Abstract Background Bowel herniation through a defect in the broad ligament of the uterus is a rare disease and few cases of recurrence have been reported. We report herein a recurrence case of a patient with broad ligament hernia (BLH), along with a review of the literature. Case presentation A 53-year-old woman complaining of abdominal pain was transported to our hospital. She had a history of laparotomy for small-bowel obstruction associated with hernia in the broad ligament of the uterus 10 years ago at a local hospital. Abdominal pelvic contrast-enhanced computed tomography revealed that the mesentery of the dilated bowels converged at a thick band in the pelvis, suggesting closed loop obstruction of the small bowel. The patient underwent urgent laparotomy and was diagnosed with bowel herniation through an opening in the broad ligament of the uterus on the right side, which was ipsilateral with the previous surgery. The hernia orifice was widened by incision and incarcerated bowel segments were released and preserved because ischemia was reversible. The membranous defect of BLH was closed by suture with braded silk strings. Conclusions Although BLH is a rare disease, patients face a significant risk of disease recurrence. Nonabsorbable suture may be advisable for closure of the hernia orifice in BLH.


2021 ◽  
Vol 108 (Supplement_3) ◽  
Author(s):  
M Soto Dopazo ◽  
E Pérez Prudencio ◽  
A Arango Bravo ◽  
C Nuño Iglesias ◽  
C Mateos Palacios ◽  
...  

Abstract INTRODUCTION Internal hernias caused by broad ligament defects are an infrequent cause of bowel obstruction. These defects may be congenital or acquired mainly by gynecological antecedents. Small bowel is the most common affected and the diagnosis is difficult due to nonspecific symptoms and absences of characteristic radiological signs. MATERIAL AND METHODS We report the cases of three women aged from 43 to 56 years old, who came to the emergency with abdominal pain, vomiting and bloating of hours duration. One patient has a history of laparoscopic appendectomy, the rest of them with no surgical history. In all of the cases, x-rays showed dilatation of small bowel loops and air-fluid levels and the abdominal TC revealed a generalized distention of bowel loops with transition point in the terminal ileum with no identifiable cause compatible with small bowel obstruction. RESULTS We decided to perform an urgent surgery with an exploratory laparotomy in one case and the rest by laparoscopic approach, finding an internal hernia occasioned by incarceration of small bowel through a broad ligament defect. In all cases, the hernia content was liberated without evidence of ischemia with no need for intestinal resection, and the defect was closed. All patients had a favourable postoperative course without complications. DISCUSSION Broad ligament defects are a rare cause of internal hernias. These are difficult to diagnose clinically as well as radiologically for an absence of characteristic signs. A high level of clinical suspicion allows early diagnosis and the treatment should be performed as soon as possible to reduce the chances of intestinal necrosis.


1960 ◽  
Vol 1 (26) ◽  
pp. 1025-1026 ◽  
Author(s):  
Jean Murray‐Jones
Keyword(s):  

Author(s):  
Ruyue Ma ◽  
Junhua Guan ◽  
Jina Chen ◽  
Ke Sun ◽  
Liwen Zhang ◽  
...  

2021 ◽  
pp. 155335062098822
Author(s):  
Eirini Giovannopoulou ◽  
Anastasia Prodromidou ◽  
Nikolaos Blontzos ◽  
Christos Iavazzo

Objective. To review the existing studies on single-site robotic myomectomy and test the safety and feasibility of this innovative minimally invasive technique. Data Sources. PubMed, Scopus, Google Scholar (from their inception to October 2019), as well as Clinicaltrials.gov databases up to April 2020. Methods of Study Selection. Clinical trials (prospective or retrospective) that reported the outcomes of single-site robotic myomectomy, with a sample of at least 20 patients were considered eligible for the review. Results. The present review was performed in accordance with the guidelines for Systematic Reviews and Meta-Analyses (PRISMA). Four (4) studies met the inclusion criteria, and a total of 267 patients were included with a mean age from 37.1 to 39.1 years and BMI from 21.6 to 29.4 kg/m2. The mean operative time ranged from 131.4 to 154.2 min, the mean docking time from 5.1 to 5.45 min, and the mean blood loss from 57.9 to 182.62 ml. No intraoperative complications were observed, and a conversion rate of 3.8% was reported by a sole study. The overall postoperative complication rate was estimated at 2.2%, and the mean hospital stay ranged from 0.57 to 4.7 days. No significant differences were detected when single-site robotic myomectomy was compared to the multiport technique concerning operative time, blood loss, and total complication rate. Conclusion. Our findings support the safety of single-site robotic myomectomy and its equivalency with the multiport technique on the most studied outcomes. Further studies are needed to conclude on the optimal minimally invasive technique for myomectomy.


2003 ◽  
Vol 268 (3) ◽  
pp. 233-235 ◽  
Author(s):  
Vorapong Phupong ◽  
Ruangsak Lertkhachonsuk ◽  
Surang Triratanachat ◽  
Thanasak Sueblinvong
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document