Energetic, economic, environmental investigation of carbon dioxide as the refrigeration alternative in new energy bus/railway vehicles’ air conditioning systems

2022 ◽  
Vol 305 ◽  
pp. 117830
Author(s):  
Yulong Song ◽  
Haidan Wang ◽  
Yuan Ma ◽  
Xiang Yin ◽  
Feng Cao
2014 ◽  
Vol 672-674 ◽  
pp. 54-60 ◽  
Author(s):  
Ting Xiang Jin ◽  
Xiao Feng Xu

As coal, oil, natural gas and other non-renewable energy consumption and increasing energy demand, the utilization of solar energy as a new energy is greatly enhanced. In this work, a grid connected photovoltaic solar air conditioning system is designed, mainly comprised of solar panel, controller, inverter, room air conditioner and other parts. Air conditioning systems rely mainly on solar photovoltaic power; achieve the effect of energy conservation and environmental protection. The experimental result indicates that the system can achieve stable operation and the utilization of solar energy driving air conditioning system to save electricity. This air conditioning system is compared with the ordinary air conditioning system, SEER can increase 10.6 ~ 29.4%, HSPF can increase 6.25 ~ 18.5%.


Author(s):  
Sapna Shrestha Kanu ◽  
Russell Binions

The excessive use of heating systems in cold climates and air conditioning systems in hotter climates is resulting in the extensive use of electricity in order to maintain such systems. This in turn leads to the greater use of fossil fuels and higher emissions of carbon dioxide and other pollutant gases. The growing amount of carbon dioxide emissions is contributing to the problem of global warming, hence increasing the need for alternative technologies to heating and air conditioning systems. One such alternative is the production of thin films which can be used as window glazing coatings to construct ‘smart windows’. These windows have the greatest use within constant climates. In cold climates, windows with high solar transmittance and low thermal emittance are needed; this allows sunlight into the building to brighten the room but stops heat from escaping thus warming the room. In constantly hot climates, materials that are transparent in the visible region but reflective in the infrared, such as thin metallic coatings, can be used to ensure that the inside of the building remains cool. These solar control coatings, however, pose a problem in varying climates such as in northern and central Europe. For these cases, materials that have altering properties owing to external surroundings could be the solution. These ‘chromatic’ materials include several categories, such as photochromic glasses and polymers, thermochromic metal oxides and electrochromic materials. This review will begin with a discussion as to the chemistry behind the solar control coatings and chromic materials including ambient radiation and the ideal of a black-body object. It will then look in depth at each class of these chromic materials considering experimental results and theoretical insight as well as production techniques and applications.


2008 ◽  
Vol 12 (3) ◽  
pp. 55-64 ◽  
Author(s):  
Dragi Antonijevic

Based on Kyoto Protocol and the decisions of European Commission R134a refrigerant, currently dominantly used in mobile air conditioning systems, needs to be phased-out. At present automotive industry looks at carbon dioxide (CO2; R744) as the refrigerant of the future. Apart from the environmental benefits discussed are the technical characteristics of carbon dioxide refrigeration cycle and mobile air-conditioning systems in comparison to R134a refrigerant. Analyzed are challenges emerged from the use of CO2 as refrigerant and improvement opportunities in regards to increase of the system performance and efficiency. Particular attention is dedicated to the advantages of CO2 utilization in prospective automotive heat pump systems.


Author(s):  
Marcelo Pereira ◽  
Arlindo Tribess ◽  
Giorgio Buonanno ◽  
Luca Stabile ◽  
Mauro Scungio ◽  
...  

One of the most important functions of air conditioning systems in operating rooms is to protect occupants against pathogenic agents transported by air. This protection is done by simultaneously controlling the air distribution, temperature, humidity, filtration and infiltration from other areas etc. Due to their low price, simple installation, operation and maintenance, window/wall air conditioning system have largely been used in operating rooms in Brazil, even if these types of equipment only recirculate the air inside the room without appropriate filtration and renovation with outdoor air. In this context, this work aims to analyse the performance of the window/wall air conditioning systems on indoor air ventilation in operating rooms by measuring particle number concentrations and carbon dioxide concentrations during different surgical procedures, in a single surgical room and in the nearby areas (corridor) for two cases: single surgery and two subsequent surgeries. In addition, the efficiency of the analysed air conditioning system was evaluated by comparing the ventilation level calculated in the surgical room with the ventilation required in order to maintain the carbon dioxide concentration within acceptable levels. The results showed that this type of air conditioning system is not appropriate for use in operating rooms since it cannot provide an adequate level of ventilation. The CO2 concentrations during surgeries, in fact, significantly exceeded acceptable values and a simultaneous increase in particle number concentration was observed. The results also showed that there is a high risk of contamination between subsequent surgeries in the same surgical room, due to residues of contaminants transported by the particles emitted during the surgeries that were not removed from the operating room by the air conditioning system. The particle number concentration measured in the second surgery, in fact, was approximately six times higher than in the first surgery.


ATZ worldwide ◽  
2001 ◽  
Vol 103 (12) ◽  
pp. 14-17 ◽  
Author(s):  
Peter Kuhn ◽  
Martin Graz ◽  
Frank Obrist ◽  
Willi Parsch ◽  
Frank Rinne

Sign in / Sign up

Export Citation Format

Share Document